Hier Klicken für das PDF Dokument!!!

                                            1.8 Watt Dual Series DC/DC Converters
Features                                                               Description
!   Low Profile Case (0.375" High)                                     These 1.8 Watt Dual DC/DC Converters are designed for high
                                                                       performance Industrial data acquisition systems and board
!   Low Noise Operation
                                                                       level products. The converter consists of a rugged bipolar
!   "LC" Section Input Filter to Reduce Reflected Ripple               switching stage, isolation transformer, and high regulation
                                                                       linear post regulator for low noise/highly stable DC outputs.
!   Wide Input Voltage Range
!   High Isolation Breakdown Voltage
    (500 VDC Minimum)
!   Long Term Output Fault Survival
!   100% Burn-In, 100% Tested
!   5 Year Warranty


                      Selection Chart
                    Input Range
                        VDC             Outputs      Outputs
      Model
                                         VDC           mA
                   MIN      MAX
    5D12.075       4.60       5.50       ±12.0         ±75
    5D15.060       4.60       5.50       ±15.0         ±60
    12D12.075     10.80       13.80      ±12.0         ±75
    12D15.060     10.80       13.80      ±15.0         ±60




                                                 1.8 Watt Dual Series Block Diagram




                                                ISOLATION
                                            TRANSFORMER                                  POSITIVE     A            3 + OUTPUT
                                                                                        REGULATOR

                                                                                                            1µF
     + INPUT 1          LC             BIPOLAR
                      INPUT           PUSH-PULL                                                                    4 CMN
                      FILTER          INVERTER
     - INPUT 2
                                                                                                            10µF

                                                                                         NEGATIVE                  5 - OUTPUT
                                                                                        REGULATOR




                                                                                           BANDGAP REFERENCE
                                                  SIX-SIDED SHIELDED STEEL CASE


                          CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                             Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

                                                                   1
                                                  1.8 Watt Dual Series DC/DC Converters
                                                                 Input Parameters*
Model                                                         5D12.075 5D15.060                               12D12.075 12D15.060                    Units
                                              MIN                     4.60                                            10.80
Voltage Range                                                                                                                                        VDC
                                              MAX                     5.50                                            13.80
                                              TYP                     100                                               80
Reflected Ripple, 0-20MHz bw                                                                                                                        mA P-P
                                              MAX                     200                                              150
Input Current Full Load                       TYP                     650                                              265
                                                                                                                                                      mA
               No Load                        TYP                     130                                              45
Efficiency                                    TYP                      55                                              57                              %
Switching Frequency                           TYP                      55                                               55                            kHz
Maximum Input Overvoltage,
                                              MAX                           6.2                                           14.5                       VDC
  100ms No Damage
Turn-on Time, 1% Output Error (2)             TYP                           4                                              4                          ms
Recommended Fuse                                                                            Slow Blow Type (3)


                                                                Output Parameters*
Model                                                         5D12.075          12D12.075                      5D15.060        12D15.060             Units
Output Voltage                                                           ±12                                             ±15                         VDC
                                              MIN                         0                                               0
Rated Load (4)                                                                                                                                        mA
                                              MAX                        ±75                                             ±60
                                              MIN                       11.88                                           14.85
Voltage Range
                                              TYP                       12.00                                           15.00                        VDC
  100% Load
                                              MAX                       12.12                                           15.15
Output Balance
                                              MAX                                                  1.0                                                 %
 (Plus to Minus Output, Full Load)
                                              TYP                                                  0.1
Load Regulation 0-100% Load                                                                                                                            %
                                              MAX                                                  0.2
Line Regulation                               TYP                                                  0.1
                                                                                                                                                       %
  Vin = Min-Max VDC                           MAX                                                  0.2
Short Term Stability (5)                      TYP                                                  0.1                                                 %
Long Term Stability                           TYP                                                  0.4                                              %/kHrs
Transient Response (6)                        TYP                                                  100                                                µs
Dynamic Response (7)                          TYP                                                   15                                             mV peak
Input Ripple Rejection (7)                    TYP                                                   60                                                dB
                                              TYP                                                   15
Noise, 0-20MHz bw                                                                                                                                   mV P-P
                                              MAX                                                   30
                                              TYP                                                  150
Temperature Coefficient                                                                                                                             ppm/°C
                                              MAX                                                  300
Short Circuit Protection to
                                                                                            Short Term, 1 Minute Maximum
 Common for all Outputs




NOTES:
                                                                                                                          A
      All parameters measured at Tc= 25° C, nominal input voltage                     (7)   Dynamic response is the peak overshoot voltage during the
*     and full rated load unless otherwise noted. Refer to the                              transient response as defined in note 6 above.
      CALEX Application Notes for the definition of terms,                            (8)   The functional temperature range is intended to give an additional
      measurement circuits and other information.                                           data point for use in evaluating this power supply. At the low
(2)   Turn on time is defined as the time from the application of power                     functional temperature the power supply will function with no
      until the output is within 1% if its final value.                                     side effects, however sustained operation at the high functional
(3)   Determine the correct fuse size by calculating the maximum DC                         temperature will reduce expected operational life. The data
      current drain at low line input, maximum load (or use the supplied                    sheet specifications are not guaranteed over the functional
      curves) and then adding 20 to 25% to get the desired fuse size.                       temperature range.
(4)   No minimum load required.                                                       (9)   The case thermal impedance is specified as the case temperature
                                                                                            rise over ambient per package watt dissipated.
(5)   Short term stability is specified after a 30 minute warm-up at full
      load and with constant line, load and ambient conditions.
(6)   The transient response is specified as the time required for the
      output to settle from a 100% step load change (rise time of step
      = 2µ Sec) to a 1% error band.




                              CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                 Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

                                                                                  2
                                                                        1.8 Watt Dual Series DC/DC Converters
                                          General Specifications *
                                            All Models                                  Units
Isolation
Isolation Voltage
  10µA Leakage                                        MIN              500               VDC
  Input-Output
Input to Output
                                                      TYP              30                 pF
Capacitance
Environmental
Case Operating Range                                  MIN            -25
                                                                                          °C
  No Derating                                         MAX             80
                                                      MIN            -30                                                                       BOTTOM VIEW                   SIDE VIEW
Case Functional Range (8)                                                                 °C
                                                      MAX             90
                                                      MIN            -55
Storage Range                                                                             °C          Mechanical tolerances unless otherwise noted:
                                                      MAX            100
Thermal Impedance (9)                                 TYP            16.5               °C/Watt       X.XX dimensions: ±0.020 inches
General                                                                                               X.XXX dimensions: ±0.005 inches
Unit Weight                                           TYP              0.9                oz          Seal around terminals is not hermetic. Do not immerse units in any
Mounting Kits                                                     MS6 & MS15                          liquid.



                                                                                                                                         Pin            Function
                                                                                                                                          1              +INPUT
                                                                                                                                          2              -INPUT
                                                                                                                                          3             +OUTPUT
                                                                                                                                          4                CMN
Typical Performance (Tc=25°C; Full Rated Load).
                                                                                                                                          5             -OUTPUT

                                     5D EFFICIENCY Vs. LINE INPUT
                   65

                              100% FULL LOAD
                   60
  EFFICIENCY (%)




                   55
                                50% FULL LOAD
                   50


                   45


                   40


                   35
                        4.6         4.8         5.0         5.2         5.4       5.6

                                             LINE INPUT (VOLTS)                                                                                          A

                                          5D EFFICIENCY Vs. LOAD                                                                          5D INPUT CURRENT Vs. LINE INPUT
                   70                                                                                                          0.7


                                                                                                                               0.6
                                                                                                        INPUT CURRENT (AMPS)




                   60
                                             LINE = 4.6VDC          LINE = 5VDC                                                0.5
  EFFICIENCY (%)




                   50                                                                                                                     100% FULL LOAD
                                                                                                                               0.4


                                                                                                                               0.3
                   40
                                                                                                                                                             50% FULL LOAD
                                                       LINE = 5.5VDC
                                                                                                                               0.2
                   30
                                                                                                                               0.1


                   20                                                                                                          0.0
                        0           20          40          60          80        100                                                0    1      2       3       4      5     6

                                                  LOAD (%)                                                                                      LINE INPUT (VOLTS)


                                               CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                                      Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

                                                                                                  3
                                                                                    1.8 Watt Dual Series DC/DC Converters
Typical Performance (Tc=25°C; Full Rated Load).

                                         12D EFFICIENCY Vs. LINE INPUT                                                                                             OUTPUT LOADING CHART
                          65                                                                                                            200


                                                                                                                                                            -Io                                               +Io




                                                                                                             -Io PERCENT OF FULL LOAD
                          60
                                                                                                                                        150
                                                                      100% FULL LOAD
  EFFICIENCY (%)




                          55


                          50                                                                                                            100



                          45
                                                        50% FULL LOAD                                                                    50

                          40


                          35                                                                                                              0
                                10            11                 12            13             14                                               0                  50                   100               150              200

                                                       LINE INPUT (VOLTS)                                                                                         +Io PERCENT OF FULL LOAD




                                              12D EFFICIENCY Vs. LOAD                                                                                OUTPUT VOLTAGE Vs CASE TEMPERATURE
                          70                                                                                                             0.8
                                                                             LINE = 10.8VDC
                                                                                                                                         0.6



                                                                                                             NORMALIZED OUTPUT (%)
                                                                                                                                                                                        NEGATIVE OUTPUT
                          60
                                                                             LINE = 12VDC                                                0.4
  EFFICIENCY (%)




                                                                                                                                                     POSITIVE OUTPUT
                                                                                                                                         0.2
                          50
                                                                                                                                         0.0

                          40                                                                                                            -0.2

                                                                 LINE = 13.8VDC
                                                                                                                                        -0.4
                          30
                                                                                                                                        -0.6


                          20                                                                                                            -0.8
                                0        20               40            60          80        100                                              -30   -20    -10     0   10        20         30     40   50     60   70   80

                                                           LOAD (%)                                                                                               CASE TEMPERATURE (Deg C)




                                     12D INPUT CURRENT Vs. LINE INPUT                                                                                      OUTPUT IMPEDANCE Vs. FREQUENCY
                         0.30                                                                                                             1

                                                                                                                                                           POSITIVE OUTPUT
                         0.25
                                                                                                                                                                                       A
  INPUT CURRENT (AMPS)




                                                   100% RATED LOAD
                                                                                                             IMPEDANCE (OHMS)




                                                                                                                                                                                         NEGATIVE OUTPUT
                         0.20                                                                                                             .1


                         0.15


                         0.10                                                                                                            .01
                                                                50% RATED LOAD
                         0.05


                         0.00                                                                                                           .001
                                0    2             4        6          8     10          12   14                                               10           100              1K                   10K         100K        1M

                                                       LINE INPUT (VOLTS)                                                                                               FREQUENCY (Hz)




                                                        CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim