3200SERIES
ELECTRICAL TEST EQUIPMENT CALIBRATOR
Insulation Testers to 5kV Ü
Portable Appliance Testers Ü
Loop Testers Ü
CompuMess Elektronik GmbH
Lise-Meitner-Str.1, 85716 Unterschleissheim RCD Testers Ü
Tel 089-321501-0 Fax 089-321501-11
http://www.compumess.de oder http://www.netzteile.de
Breakdown / Hipot Testers Ü
Ground Bond Testers Ü
Ü THE COMPLETE SOLUTION
FOR ELECTRICAL TEST EQUIPMENT CALIBRATION
3200 Electrical Test Equipment Calibrator - Five calibrators in one instrument · RCD, Insulationcalibrator for PATs · Loop
The worlds first
& Breakdown Testers
Insulation Testers Resistance to 10GOhms Test Voltage Measurement Continuity Resistance & Current AC Voltage Output
Providing all the functionality required Continuously variable Insulation Measures insulation test voltage & 5 AC voltage outputs at
3 ranges to 1kOhm (variable from
resistance to 10GOhms @ 1kV. current at nominal 1mA load for 50V·100V·200V·230V·400V
to calibrate all aspects of these popular 0.1Ohm to 20Ohms) and current
Use the optional adaptor to check 16th edition equipment or 0.5mA for calibrating voltage ranges
instruments. measurement to 320mA (@1Ohm)
5kV testers with active guard. for older equipment.
PATs & Earth Bond Testers Earth Bond Resistance & Current Insulation Resistance Flash Voltage & Leakage Current Load Testing
The 3200 is the quickest solution for
10 precision resistance values with Class 1 & 2 flash voltage & current Open circuit, short circuit and
calibrating all PAT functions. Also ideal current measurement from 100mA to
Adjustable resistance to 10GOhms
- ideal for checking pass/fail levels measurement plus 3 AC leakage 0.13kVA load checks PAT
for calibrating earth/ground bond testers 30A into 0.1 Ohms ranges to 7mA operation / run tests
with up to 30A test current.
RCD Testers RCD Current Measurement to 3A RCD Trip Time 20ms to 5s RCD Current Duration
Simply plug in the RCD tester to the RCD RMS and peak current measurements
Accurate & repeatable trip times The 3200 makes this normally difficult
for all types of tester using digital
test socket and start calibrating. The 3200 entered simply via the keyboard measurement straight forward with this
waveform capture & analysis.
will check and detect a faulty tester. provide easy calibration. dedicated function
Graphical Indication of phase start
LOOP Testers Loop Resistance
Calibrate these instruments quickly and
safely. The auto loop options ensures
accurate correction of the supply line
10 precision resistance values
incorporating line impedance - either
entered directly or obtained using the
Ü SOCKETS
impedance. auto loop measurement option Localised LOOP / RCD
Socket Options UK /
Breakdown Testers High Voltage Measurement to 12kV EURO / Australian*
External adapter for the calibration of 4 Voltage ranges : AC/DC 3kV & 12kV
6 Current range : AC/DC 200uA, 2mA & 20mA
Breakdown / hipot testers. Measures AC/DC 9 Load resistors for current measurements :
voltage to 12kV and output current to 20mA 50kW (20mA) to 20MW (20uA) @ 1kV
A Breakthrough In Electrical Test Equipment Calibration
The increasing demand for the calibration of electricians tools brought on by government regulations
and quality systems has presented a problem for calibration laboratories. Although these types of
electrical equipment are relatively low in accuracy, they are difficult to calibrate due to the varied test
equipment required, skill level and safety aspects associated with using live mains on an unprotected
line. This precluded cost effective calibration...UNTIL NOW. Ü OPTIONAL ADAPTERS
The 3200 revolutionises the process of calibration, providing a safe and controlled method to calibrate 5kV INSULATION TESTER PORTABLE APPLIANCE BREAKDOWN / HIPOT
these types of electrical instruments with a minimum level of training. Connect directly to a PC using ADAPTER FOR MEGGER TESTER FLASH TESTER ADAPTER
Transmille's ProCal software via the built in RS232 interface (isolated for safety) to provide a turn-key INSULATION TESTERS TEST ADAPTER
*Other regions supported
solution for automated calibration. using adapter lead
Automate Calibration with ProCal - the easy to use calibration software For a FREE evaluation CD contact our sales desk or visit
www.transmille.com
Ü IMPROVED PRODUCTIVITY Ü CALIBRATION PROCEDURES Ü EXPAND FOR JOB CONTROL
ProCal software controls the calibrator and guides Procedures can be easily downloaded from a ProCal-Track provides an inventory & calibration
the user through a sequence of tests, recording library of procedures from www.transmille.com or management module to handle job control from
the results automatically ensuring fast, repeatable created using the integrated procedure builder goods-in to dispatch, and links seamlessly with
calibration that can be perfomed with a minimum wizard. ProCal.
of training. From single station to full network setups,
Transmille software is flexible to work the way you
Ü DOCUMENTATION OF RESULTS Ü THE COMPLETE SOLUTION want to.
ProCal produces a selection of professionally ProCal provides the flexibility to grow for
formatted reports, including certificates and expanding requirements to support calibration of For further details see the Transmille
other types of instruments including DMMs, power · Intuitive graphical user interface
calibration labels - ideal for quality systems such
supplies, oscilloscopes - even pressure, torque & software brochure - click on to...
as ISO9000 and ISO17025. Custom reports can · Certificates printed directly on plain paper
Ü ULTRA PORTABLE SYSTEM also be written using Seagate Crystal Reports®.
dimensional disciplines. www.transmille.com · Professional labels using dedicated label printer
Ideal for on-site calibration
Ü 3200 Electrical Test Equipment Calibrator
Continuity Testing Pat Testing
Earth Bond Resistance
Cont. Variable Range : 0.5W to 2kW (0.5W Resolution)
Alternative Range (Option) : 0.1 to 20 (0.01 Res.) ; 100W ; 1kW Fixed
Values : See Loop Values
Accuracy : 0.5% ± 4mW
Standard Accuracy : 1% ± 25mW Resolution : 0.1mW (to 10W) : 1mW (to 1kW)
High Accuracy (Option) : 0.25% ± 25mW
Earth Bond Current Measurements
Continuity Current Measurement (Into 1)
Ranges : 100mA, 10A, 30A
Range : 0 to 320mA (0.1mA Resolution) Resolution : 1mA, 10mA, 10mA
Accuracy : 1.3% ± 6 Counts Accuracy : 1.5% ± 6 Counts
Insulation Testing PAT Insulation Resistance
Range : 0 to 2GW (10GW Option : 5%) Range : 100kW to 1GW (10kW Resolution)
Accuracy : See Insulation Resistance
Accuracy : 10kW to 5MW 0.3% (0.1% Option)
5MW to 2GW 3% (1% Option)
PAT Leakage
Resolution : 10kW Ranges : 2mA, 4.7mA, 7.7mA (1uA Resolution)
Max Volt/Power : 1.1kV or 1 WATT (5kV Option) Accuracy : 1.5% ± 2 Counts
Insulation Test Voltage Measurement
Ranges : 50V, 100V, 250V, 500V, 1kV PAT Leakage Test Voltage
(0.1V Resolution) Range : 100V to 300V RMS (0.1V Resolution)
Current Measurement : 0.5mA, 1mA Accuracy : 1.5% ± 9 Counts
Accuracy : 1% ± 8 Counts
AC Voltage Output Load Testing
Ranges : S/C, O/C & 0.13kVA
Range : 100V, 200V, 230V, 300V, 400V
Accuracy : 440W ± 5%
Accuracy : 0.2% ± 1 Counts
Flash Testing (Option)
RCD Testing CLASS 1
Time Range : 20ms to 5s (10ms Resolution) Range : 1kV to 1.8kV (1V Resolution)
Accuracy : ± 0.7ms Load Resistance : 600kW (2.5mA @ 1.5kV)
Current Range : 3mA to 3A CLASS 2
Resolution : 0.01mA (to 200mA), 0.1mA (to 3A) Range : 2kV to 3.6kV (1V Resolution)
Accuracy : < 190ms 5% ± 20 Counts Load Resistance : 1.2MW (2.5mA @ 3kV)
: up to 5s 1.2% ± 6 Counts
Accuracy (Class 1&2) : 4% ± 10 Counts
Timing Modes : Immediate & Zero Crossing
Current Modes : I, ½ I, 2I, & 5I
Flash Current Measurement (Option)
Display Modes : 0° and 180° Phase
Range : 1mA to 3mA Resolution : 10uA
LOOP Testing Line Voltage Measurement
Resistances
Range : 200V to 260V : 0.1V Resolution
0.05W, 0.1W, 0.22W, 0.33W, 0.5W, 1W, 5W, 10W, 100W, 1kW Accuracy : 0.8% ± 6 Counts
Resolution : 0.1mW (to 10W) ; 1mW (to 1kW)
Accuracy : 0.5% ± 4mW General Specification
Auto Loop (Option)
Line Power : 230V/110V 50Hz /60Hz
Maximum Correction : 2W Automatically Dimensions : 45 x 44 x 14cm · Weight : 10kgs
Resolution
Accuracy
:
:
100µW
±18mW } corrects for
supply loop
Warm-up Time : Double the time since last used
up to 20 minutes maximum.
Measurement Current : 4A impedance. Interface : RS232
Ordering Model 3200 Electrical test Equipment Calibrator 3200 Breakdown Tester Calibration Adapter BREAKD
Information High accuracy - improves resistance accuracy HIACC Low Range Continuity Option LOWR
Extend insulation resistance to10GW 10G 5kV Insulation Tester Adapter (for Megger BM11) EXT5kV
Automated loop (line-earth) measurement AUTOL Carry Case CASE
External PAT flash voltage measurement (up to 3kV) FLASH UKAS Certificate 3200UKAS
AGENT
UNIT 4 SELECT BUSINESS CENTRE,
LODGE ROAD, STAPLEHURST, KENT.
TN12 0QW. UNITED KINGDOM.
TEL : +44 (0) 1580 890700 CompuMess Elektronik GmbH
FAX : +44 (0) 1580 890711 Lise-Meitner-Str.1, 85716 Unterschleissheim
EMAIL : sales@transmille.com Tel 089-321501-0 Fax 089-321501-11
http://www.compumess.de oder http://www.netzteile.de
WWW.TRANSMILLE.COM
0324
Due to continuous development specifications are subject to change
Windows is a registered trademark of Microsoft Corporation
All other product names mentioned herein may be trademarks of their respective companies. V1.00