OPTIONS OVERVIEW
For The 3200 Electrical Test Equipment Calibrator
HIGH ACCURACY RESISTANCE OPTION
Higher Accuracy - approximately 3 times better for the insulation resistance and continuity resistance.
Recommended for calibration laboratories which may wish to use the 3200 for other uses and also
provides the accuracy for more accurate insulation testers in the future
- NOT RETRO-FITTABLE
10GOHM OPTION
Transformers
Extends the resistance range for the standard 2G Ohms to 10G Ohms to cover calibration of insulation
testers with higher ranges - RETRO-FITTABLE (requires return to factory for fitting)
AUTO LOOP OPTION
A48062667A000G
Auto loop measures the supplied loop impedance and automatically adds this to the internal resistance
value, enabling the value displayed by the 3200 to be directly used for calibration of loop testers. Without
this option the loop value (at the test socket) must be measured and entered manually into the calibrator.
The auto loop option is particularly useful when the supply loop impedance is unstable or the socket /
location of the calibrator changes (e.g. on site work) - NOT RETRO-FITTABLE.
EXTERNAL RESISTOR OPTION
Allows the user to add two custom resistance values for use with the LOOP and PAT Earth Bond
resistance modes. These additional resistors supplied by the user are connected to two sets of terminals
on the rear panel - RETRO-FITTABLE.
Input Environmental
Voltage 230 VAC Operating Temperature 0 to 40 deg. C with no derating
Line Frequency 50 Hz Storage Temperature -30 to +85 deg. C
Configuration Wall Mount; no Ground Relative Humidity 5% to 95% non-condensing
EXTERNAL 5kV ADAPTOR Altitude 0-10,000 feet
Electrical Cooling Convectional - non vented case
Provides a low cost solution for calibrating 5kV insulation testers (Megger BM11 etc.).
Topology Step Down AC/AC Transformer Mechanical
Dielectric Withstand
Testers must have Meets the requirements and be able to supply at least 5mA output current.
a guard terminal of safety
agencies. Case and Dimensions 3.2 L x 2.2 W x 1.9 H (in.) 81 L x 55 W x
The adaptor multiplies the resistance output from the 3200 by 10, therefore being able
Protection Current, Thermal, or Energy Limiting 48 H (mm)
to simulate up to 1T Ohm if the 10G option is fitted Case Material
to the 3200. Black 94 V1 Polycarbonate
Safety Approvals Weight
Please note the adaptor does not measure the 5kV test voltage. 18 ounces; 520 grams
Configuration Wall Mount; no Ground
TUV EN60950
PAT FLASH ADAPTOR
Measures the flash test voltage and current generated by PATs when performing
Class 1 and 2 (1.5kV / 3 kV) FLASH tests.
Two measurement modes are available
Zero Load : AC Voltage only is displayed
Under Load : AC Voltage and current (into nominal 1mA load) is displayed
HI-POT / FLASH / BREAKDOWN TESTER ADAPTOR
Test HI-Pot / Flash / Breakdown testers using this external adaptor.
Measure AC / DC Voltage to 12 kV (3kV & 2kV Ranges) and Currents from 200uA to
20mA @ 1 kV into 9 selectable resistance loads (3 current ranges).
Incorporates LED range indication.
OPTIONS OVERVIEW
For The 3200 Electrical Test Equipment Calibrator : V1.00
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de