Hier Klicken für das PDF Dokument!!!

  100MS/s PXIBus
  Arbitrary Waveform
  Generator



MODEL TE5201
 Single-channel 100MS/s waveform generator
 Multiple instrument synchronization
 14 Bit vertical resolution                                                         Waveform sequencing with up to 4096 segments
 2 Meg waveform memory                                                              and sequences
 1 ppm clock accuracy and stability                                                 Occupies a single PXI slot only
 Extensive modulation capabilities AM, FM, Arbitrary                                Ultra fast waveform downloads using DMA
 FM, FSK, Ramped FSK and Sweep                                                      Extremely low phase noise carrier
 10 digits sample clock frequency setting, limited by                               ArbConnection software for easy waveform creation
 1µS/s                                                                              & control



Model 5201 is a Single-Channel PXI-based           narrow channel width. A high sample rate of         throughput in a way that cannot be duplicated
Arbitrary Waveform Generator. It is a high         100MS/s makes the 5200 an ideal modulation          by other competing products.
performance waveform generator that                source for troubleshooting new encoding             Sequences of up to 4096 Waveforms
combines many powerful functions in one small      schemes. The 5200 also provides high-speed          Powerful sequencing capability allows linkage
package. Supplied free with the instrument is      waveforms to simulate signal distortion, power      of up to 4096 waveform segments and/or bursts
ArbConnection software, which is used for          line cycle dropouts, video signals, component       (repeated segments) into strings.
controlling the 5200 and for generating, editing   failures and power supply transients.               A segment can be repeated up to 128K times
and downloading waveforms from a remote            14 Bit Resolution                                   in burst mode. Sequenced functions run
computer.                                          The 14-bit resolution provides 16,384 output        continuously or are initiated by a trigger. It is
PXIbus: A Cost Effective Format                    levels. This means that even audio waveforms        also possible to mix continuous and triggered
The 5200 is a sensible alternative to a GPIB-      can be generated with excellent fidelity. It also   segments within one sequence. These
based waveform generator when developing           allows video - and other complex waveforms          sequencing features permit the creation of
a PXI-based test system. The 5200 provides         - to be generated with small details                complex waveform or pulse patterns using
a synergistic combination of a function            superimposed on large signals, in order to test     minimal amounts of memory. Sequences are
generator, arbitrary waveform synthesizer,         the response of receiving systems.                  created by writing a sequence table. Sequence
programmable sequencer, pulse generator,           2Meg Waveform Memory                                table download is extremely fast because
and modulation generator in one instrument.        The 5200 provides 2Meg of waveform memory           ArbConnection writes to registers and does
The 5200 delivers all this at a lower cost than    as standard, far more than competitive models.      not require the overhead of an embedded
comparable bench-type, or VXI-based                This waveform memory is accessible via a            controller.
instruments. This versatility ensures that the     high-speed interface. Also, waveform memory
Model 5200 will adapt to future testing needs      is segmentable, allowing the storage of up to
as well as current ones.                           4096 different waveforms of variable size. This
100 MS/s Sample Rate                               allows test software to switch between many
New technology requirements are driving            different waveforms rapidly and without having
communications systems to use increasingly         to download multiple times, enhancing test
100MS/s PXIBus                                                                                            Model TE5201
Arbitrary Waveform
Generator



Flexible Triggering Capability                     not really care how it is done but the end          generated by the main output. Place 2 or
Combining PXIbus trigger lines with the 5200       result is magnificent: functions like wide-         more Model 5200`s in a chassis and harness
sync capability transforms the instrument          band FM, wander, linear and logarithmic             the power of multi-instrument synchronization
into an Arbitrary Trigger Generator. In addition   sweep are easily created and executed by            to create multiple, phase-controlled output
to continuous output, the instrument can           the generator.                                      channels. Then vary module-to-module
also wait for a trigger to initiate a single       A unique and extremely useful feature of            phase offsets to create multi-phase signal
waveform, a burst of waveforms or a                ArbConnection is the FM Composer. The               source. Really exciting!
sequence of waveforms. Triggers can also           FM composer screen looks very much like             ArbConnection
be used to advance a sequence of                   the Wave Composer screen except the "Y"             Unlimited Source of Arbitrary Waveforms.
waveforms one segment at a time. The 5200          axis is given in units of frequency, so             With the ArbConnection software you can
accepts the trigger s for multiple sources:        waveforms you create using the FM                   control instruments functions, modes and
eight backplane trigger lines plus STAR            composer generate frequency change over             features. You can also create virtually an
trigger, front panel trigger input, and manual     time. You can create any arbitrary waveform         unlimited variety of test waveforms. Freehand
commands such as *TRG                              shape or even use the equation editor to            sketch allows you to draw your own custom
Sample Clock Agility                               generate exotic shapes which eventually you         waveform for quick analysis of analog signals.
The Model 5200 has outstanding low phase           can use to frequency modulate your main             You can use the built-in equation editor to
noise characteristics and carrier stability.       output.                                             create your own exotic functions. Add or
Such characteristics are very much needed          Arbitrary Waveforms                                 subtract components of a Fourier series to
for telecommunication and channel                  The last but not least is flexibility of the 5200   characterize digital or analog filters or, inject
separation applications. On the other hand,        as an Arbitrary Waveform Generator.                 random noise into a signal to test immunity
the output of the 5200 can be made                 Combined with the power of ArbConnection,           to auxiliary noise.
extremely agile for applications needing           there is no limit to what you can create and
sweep, FSK and FM. The sample clock of             generate. Waveform coordinates can be
the instrument is derived from a DDS (Direct       imported from a variety of sources such as
Digital Synthesis) circuit so controlling          MathLab, ASCII files etc. Anything you can
instantaneous frequency is a matter of             show on one of the composer screens is
changing its input bits. You, as a user, should    downloaded in a split of a second and
100MS/s PXIBus                                                                                            Model TE5201
Arbitrary Waveform
Generator



Service and Support                                 Applications                                       Three-year Warranty
Beyond providing precision Test &                   For expert technical assistance with your          Every Tabor Electronics instrument comes with
Measurement instruments, Tabor Electronics          specific needs and objectives, contact your        a three-year warrantee. Each one has full test
provides unparalleled service and support,          local sales representative or our in-house         results, calibration certificate, and CD containing
and is continuously finding new ways to bring       applications engineers.                            product's manual and complete software
added value to its customers.                                                                          package. Our obligation under this warranty is
Our after-sales services are comprehensive.         Manuals, Drivers, and Software Support             to repair or replace any instrument or part
They include all types of repair and calibration,   Every instrument comes equipped with a             thereof which, within three years after shipment,
and a single point of contact that you can turn     dedicated manual, developer libraries, IVI         proves defective upon examination. To exercise
to whenever you need assistance. As part of         drivers, and software. However, if your specific   this warranty, write or call your local Tabor
our extensive support, we offer individualized,     manual is lost or outdated, Tabor Electronics      representative, or contact Tabor Headquarters
personal attention Help Desk, both online and       makes it possible to log-on to its Download        and you will be given prompt assistance and
offline, via e-mail, phone or fax.                  Center and get the latest data in a click      .   shipping instructions.

Tabor Electronics maintains a complete repair       Product Demonstrations
and calibration lab as well as a standards          If your application requires that you evaluate
laboratory in Israel and USA. Service is            an instrument before you purchase it, a hands-
also available at regional authorized               on demonstration can be arranged by
repair/calibration facilities.                      contacting your local Tabor Electronics
Contact Tabor Electronics for the address of        representative or the Sales Department at our
service facilities nearest you.                     Corporate Headquarters.
Specification                                                                                             Model TE5201
100MS/s PXIBus
Arbitrary Waveform
Generator


STANDARD WAVEFORMS                                   RAMP                                                                 continuously through a pre-
                                                                                                                          programmed sequence table
Waveforms:          Sine, Triangle, Square, Pulse,   Frequency Range:    100µHz to 12.5MHz
                    Ramp, Sinc (Sine(x)/x),          Adjustable                                        Stepped Sequence
                    Gaussian Pulse, Exponential      Parameters:                                       Advance:         Current segment is sampled
                    Fall, Rising Pulse, Noise, DC.       Delay           0% to 99.9% of period                          continuously, external trigger
                                                         Rise Time       0% to 99.9% of period                          advances to next
Frequency Range: Waveform dependent                      Fall Time       0% to 99.9% of period
Source:          Internal synthesizer                                                                                   programmed segment.
                                                     SINC (SINE(x)/x)                                                   Control input is TRIG IN
SINE                                                                                                                    connector.
                                                     Frequency Range: 100µHz to 6.25MHz                Single Sequence
Frequency Range: 100µHz to 50MHz                     "0" Crossing:    4 to 100 cycles                  Advance:         Current segment is sampled
Band Flatness:   5% to 10MHz; 20%,                                                                                      to the end of the segment
                 to 50MHz                            GAUSSIAN PULSE                                                     including repeats and idles
Programmable                                                                                                            there. Next trigger advances
Parameters:      Start phase, 0 to 360°              Frequency Range: 100µHz to 6.25MHz
                                                                                                                        to next segment. Control input
Harmonics and                                        Time Constant: 10 to 200
                                                                                                                        is TRIG IN connector.
non-related                                                                                            Mixed Sequence
                                                     EXPONENTIAL FALL/RISING PULSE
spurious:        at 5Vp-p < -55dBc for carrie                                                          Advance:         Each step of a sequence can
                 frequencies 1MHz                    Frequency Range: 100µHz to 6.25MHz                                 be programmed to advance
                 < -45dBc for carrier frequencies    Time Constant:   -20 to 20                                         either a) automatically
                 5MHz                                                                                                   (Automatic Sequence
                 < -35dBc for carrier frequencies    REPETITIVE NOISE
                                                                                                                        Advance), or b) with a trigger
                 10MHz                                                                                                  (Stepped Sequence Advance)
                                                     Bandwidth:          25MHz
                 < -22dBc for carrier frequencies                                                      Advance Source: External, Internal or software
                 50MHz                               DC                                                                 trigger
Total Harmonic                                                                                         Sequencer steps: From 1 to 4096
Distortion:      0.05% to 100kHz                     Range:              -100% to 100% of amplitude
                                                                                                       Segment loops: From 1 to 128k
                                                     ARBITRARY WAVEFORMS
TRIANGLE                                                                                               COMMON CHARACTERISTICS
                                                     SAMPLE CLOCK
Frequency Range: 100µHz to 12.5MHz                                                                     MAIN OUTPUT
Start phase:     0 to 360°C                          Range:             100mS/s to 100MS/s
                                                                                                       Connector:         Front panel BNC
                                                     Vertical
SQUARE                                                                                                 Stand-by:          Output Off or Normal
                                                     Resolution:        14bits
                                                                                                       Impedance:         50W, ±1%
Frequency Range:    100µHz to 50MHz                  Waveform
                                                                                                       Protection:        Protected against temporary
Duty cycle:         1% to 99%                        Memory:            2Meg points standard
                                                                                                                          short to case ground
Rise/Fall time:     <10ns                            Download Rate: 5Meg points per second
Aberration:         <5% ±10mV                        MEMORY SEGMENTATION                               FREQUENCY
PULSE                                                No. of Segments: 1 to 4096                        Resolution:        10 digits limited by 1S/s
                                                     Min Segment Size: 16 points                       Accuracy:          1ppm
Frequency Range:    100µHz to 6.25MHz                Memory Interleave: 4 (All trace lengths must be   Stability:         1ppm
Adjustable                                                              multiples of 4)
                                                                                                       REFERENCE
Parameters:
    Delay           0% to 99.9% of period            SEQUENCED ARBITRARY WAVEFORMS                     Standard:          0.0001% (1ppm TCXO) initial
    Rise Time       0% to 99.9% of period                                                                                 tolerance over a 19°C to 29°C
                                                     Operation:     Permits division of the memory
    High Time       0% to 99.9% of period                                                                                 temperature range; 1ppm/°C
                                                                    bank into smaller segments.
    Fall Time       0% to 99.9% of period                                                                                 below 19°C and above 29°C;
                                                                    Segments may be linked, and
Rise/Fall time:     <10ns                                                                                                 1ppm/year aging rate
                                                                    repeated in user-selectable
Aberration:         <5% ±10mV                                                                          External:          10MHz TTL, 50%
                                                                    fashion to generate extremely
                                                                                                                          ±2% duty cycle
                                                                    long waveforms.
                                                     Advance Modes: Automatic Sequence Advance         AMPLITUDE
                                                                    No triggers required to step       Range:             80mV to 8Vp-p, into 50W;
                                                                    from one segment to the next.                         Double into open circuit
                                                                    Sequence is repeated               Resolution:        4 digits
Specification                                                                                             Model TE5201
100MS/s PXIBus
Arbitrary Waveform
Generator


ACCURACY(1kHZ)                                    INPUTS                                               FSK
800mV to 8Vp-p     ±(1% + 10mV)                   TRIG Input                                           Carrier Sample
80mV to 799.9mVp-p ±(1% + 1mV)
                                                  Connector:       Front panel BNC                     Clock Range:     100mS/s to 100MS/s
OFFSET                                            Impedance:       10kW, ±5%                           Source:          External, Front panel Trigger
                                                  Threshold Level: TTL                                                  input BNC.
Range:            0 to ±3.6V, amplitude           Min Pulse Width: 20ns                                                 Low level Carrier sample clock
                  dependent                       Slope:           Positive or negative                                 High level Hop frequency
Resolution:       2.2mV                                            going edge.                         Frequency Range: From 10MHz to DC
ACCURACY                                          10 MHz REFERENCE INPUT                               FSK Delay:       Minimum 1 waveform
4V window:        ±(1% of reading + 1% of                                                                               cycle + 50ns
                                                  Connector:       Front panel SMB
                  amplitude + 2mV)                Impedance:       10kW, ±5%                           RAMPED FSK
400mV window:     ±(1% of reading + 1% of         Threshold Level: TTL
                  amplitude + 200V)               Duty Cycle:      50%, ±5%                            Ramp Time Range: 10s to 1s, 3 digits, ±0.1%
FILTERS           50MHz Elliptic                  MODULATION                                           Sweep
                  25MHz Elliptic
                                                  FM                                                   Carrier Waveforms: Sine, Square, Triangle, Ramp,
SYNC/MARKER OUTPUT                                                                                                         Arb
                                                  Waveform                                             Type:               Linear or Logarithmic
Outputs:          Front panel SYNC Output         Modulation:         Sine, Triangle, Square, Pulse,   Direction:          Up or down, depending on
                  BNC connector                                       Ramp, Sinc (Sine(x)/x),                              the start and stop setting
                  PXI Backplane TTLTrig 0                             Gaussian Pulse, Exponential      Sweep Time:         1ms to 1000 s, 7 digits, ±0.1%
                  through 7, programmable                             Fall, Rising Pulse, Noise, DC,   Range:              100mS/s to 100MS/s
Impedance:        50W, ±1%                                            Arb                              Trigger Advanced
Level:            >2V into 50W, 4V nominal into   Source:             Internal                         Mode:               Automatic, Triggered, Gated
                  10kW                            Resolution:         10 digits                                            or Software Command
Protection:       Protected against temporary     Accuracy:           0.1%                             Marker
                  short to case ground            Modulating Frequency                                     Output & Level: Same as SYNC output.
Validators:       BIT, LCOM                       Distortion:         <0.1%                                Position:       Programmable for selected
Position:         Point 0 to n, Programmable      Deviation Range: 100mS/s to 100MS/s                                      frequency
                  with 4-point resolution         Trigger
Width Control:    Programmable                    Advanced Mode: Automatic, Triggered, Gated           TRIGGERING CHARACTERISTICS
   Range:         4 to 100000 waveform points                         or Software Command
   Resolution:    4 points                                                                             TRIGGER SOURCES
                                                  Marker
Source:           Main output                         Output & Level: Same as SYNC output.             EXTERNAL
SINEWAVE OUTPUT                                       Position:       Fixed at carrier frequency       Connector:          Front panel BNC
                                                  FM - BUILT-IN STANDARD WAVEFORMS                     Level:              TTL
Connector:        Front panel SMB                 Carrier                                              Slope:              Positive or negative
Impedance:        50W, ±1%                        Waveforms:          Sine, Square, Triangle and       Frequency:          DC to 5MHz
Level:            1V into 50W                                         Ramp                             Impedance:          10kW, DC coupled
Protection:       Protected against temporary     Modulation                                           INTERNAL
                  short to case ground            Frequency Range: 1 mHz to 100 kHz
Source:           Sample clock frequency                                                               Range:              100mHz to 2MHz
Frequency Range                                   FM - DOWNLOADED ARBITRARY WAVEFORMS                  Resolution:         7 digits
and Resolution:   Same as Sample clock            Modulation Source:User waveform, any shape,          Accuracy:           0.01%
Flatness:         -3dB at 100MHz                                   10 to 20000 waveform points         Software:           SCPI command
Total Harmonic                                    Modulation sample                                    Backplane:          TTLTrig0 through TTLTrig7;
Distortion:       0.3% to 100kHz                  clock Range:     1mS/s to 2MS/s                                          STAR
Harmonics and                                     Download Rate: 5Meg points per second
non-related
spurious:         -55dBc to 1MHz
                  -45dBc to 10MHz
                  -35dBc to 1000MHz
Specification                                                                                              Model TE5201
100MS/s PXIBus
Arbitrary Waveform
Generator


TRIGGER START PHASE                                  Phase Offset Between                              ORDERING INFORMATION
                                                     Instruments:     Programmable from 0 to n
Description:       Waveform starts from point n                       points                           MODEL                5201
                   and completes at point n-1.
Range:             0 to 1999999 waveform points      GENERAL                                           100MS/s PXIBus Arbitrary Waveform Generator
                   (2Meg)
Resolution:        4 points                          Power
                                                     Requirements:      10Wmax
START/STOP CONTROL (BREAKPOINT)                      Current
                                                     Consumption:       +5V - 30mA
Range:            0 to 1999999 waveform points                          +12V - 200mA
                  (2Meg)                                                -12V - 200mA
Source:           External (Rear Panel Trigger                          +3.3V - 1.4A
                  Input BNC) or software             Operating
                  command                            temperature:       0ºC - 40ºC
Resolution:       4 points                           Humidity
Breakpoint Error: ±4 points                          (non-condensing)   11ºC to 30ºC: 85 %
SYSTEM DELAY                                                            31ºC to 40ºC: 75 %
                                                     Storage
Trigger to                                           temperature:       -40ºC to + 70ºC.
waveform output: 1 Sample Clock+120ns                Dimensions:        Single width, 3U high
                                                     Weight:            Approx 0.5kg
GATED MODE         External signal enables           Safety:            Designed to meet IEC 1010-
                   generator. First output cycle                        1, UL 3111-1,
                   synchronous with the active                          CSA 22.2 #1010
                   slope of the triggering signal.   EMC:               CE marked.
                   Last cycle of output waveform     Reliability:       MTBF per MIL-HDBK-217E,
                   always completed                                     25°C, Ground Benign
BURST                                                Workmanship
                                                     Standards:         Conform to IPC-A-610D
Waveforms:         Sine, Triangle, Square, Pulse,    Supplied
                   Ramp, Sinc (Sine(x)/x),           Accessories:       CD containing Operating
                   Gaussian Pulse, Exponential                          Manual, ArbConnection
                   Fall, Rising Pulse, Noise, DC,                       software and developer
                   Arb                                                  libraries.
Number of cycles                                     Warranty:          3 years standard
per burst:       1 to 128k
Trigger source:  Manual, External or Internal
MULTI-INSTRUMENT SYNCHRONIZATION
Description        Multiple instruments can be
                   connected together and
                   synchronized to provide multi-                                         CompuMess Elektronik GmbH
                   channel synchronization.                                      Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                               Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
SAMPLE CLOCK                                                                       info@compumess.de · www.compumess.de
Source:            From Master card to slave                                                     www.netzteile.de
                   boards through the local bus
Range
and Resolution:    Same as Sample Clock, but
                   limited to 80MS/s
Initial Skew:      <20ns to the first master;
                   20ns cumulative to additional
                   slaves