Hier Klicken für das PDF Dokument!!!

                                         7600 Plus Precision LCR Meter
USES:
· Production Testing of LCR
                                                       PRELIMINARY
  Components                             The 7600 Plus LCR Meter performs precision impedance measurements over a fre-
· Frequency Response, Component          quency range of 10 Hz to 2 MHz. The instrument can measure 14 different imped-
                                         ance parameters with 0.05% accuracy, meeting today's requirements for component
  & Sensor Characterization
                                         and material testing. The ease of use and user-friendly menu programming makes
· Component Screening                    the 7600 Plus ideal for applications in product development, incoming inspections,
· Material Testing                       or production line testing.

· Quality Assurance Testing
                                         14 Different Impedance Parameters: Measure and display any two parameters
· Measuring Dielectric Constant          simultaneously to achieve coverage and flexibility not previously available.
  Using Standard Test Cell
                                         Automatic Test Sequencing: Run up to six different tests in sequence with a single
FEATURES:                                push of the start button. Each test can have different conditions and limits.
· Frequency Range 10 Hz to 2 MHz         Swept Measurements: Fast and accurate swept parameter measurements, graphical
· 0.05% Basic Measurement                or tabular, for verification of component and material response to changes in AC test
  Accuracy                               frequency, AC test voltage, or AC test current without the need for complex pro-
                                         gramming or an external controller.
· 7 Digit Measurement Resolution
                                         Program and Data Storage: Test setups can be stored and recalled from either
· Programmable Test Voltage and
                                         internal memory or from standard USB memory stick. The front panel can be
  Current                                locked out with password protection to ensure procedures are run the same way
· Auto Ranging                           every time. Measured data can be stored on a USB memory stick and then trans-
                                         ferred to PC for data reduction and analysis.
· Test Setup and Measurement Data
  Storage                                Load Correction: Substantially improves instrument accuracy by performing
· Four-Terminal Kelvin Connections       measurements on a known standard and applying correction to subsequent meas-
                                         urements. Ideal for repetitive testing of identical devices at like test conditions.
· Standard USB Host Port, RS-232,
  Handler, Parallel Printer Interfaces   Automatic Calibration Procedure: The 7600 Plus can be calibrated without
                                         returning the unit to the factory using the NIST traceable QuadTech Calibration Kit,
· Optional IEEE-488                      reducing downtime and calibration costs.
· Graphical and Tabular Display of
                                         Easy to Use: Large LCD graphics display and user friendly menu driven interface
  Swept Frequency, Voltage and
                                         allows the 7600 Plus to be put on line fast, providing useful measurements by oper-
  Current Measurements                   ators with little or no training.
· Sequence Testing of Up To 6
  Individual Tests
                                                                                           For more specifications, see
· Load Correction                                                                                www.quadtech.com
· Binning (15)
· Built-in Auto Calibration Routine                                                                   For more information
                                                                                                     about special purchase,
                                                                                                       rent & lease options,
                                                                                                                        call
                                                                                                              1-800-253-1230
                                                                                                        Fax 1-978-461-4295
                                                                                                        Intl. 1-978-461-2100




                                            HIPOT TESTERS · LCR METERS · MEGOHMMETERS · MILLIOHMMETERS · CABLE TESTERS
Product Specifications
                         7600 Plus                                                                                                 Sweep Result:                    Primary parameter vs. frequency, voltage or current
                                                                                                                                                                    Graphical or Tabular Format
                         Measured Parameters:                   Any two of 14 parameters measured and
                                                                                                                                                                    Up to 200 measurement points per sweep
                                                                displayed simultaneously, user selectable
                                                                                            Basic Measurement Accuracy*            Sequencing Result:               Displays up to 6 sequential test results, primary and/or
                            Parameter                Measurement Range                               Speed                                                          secondary
                                                                                         Fast        Medium      Slow
                           Cs, Cp              00000.01 fF to 9.999999 F                 ±0.5%       ±0.25%      ±0.05%            AutoAcc:                         Automatic calculation and display of overall instrument
                           Ls, Lp              0000.001 nH to 99.99999 H                 ±0.5%       ±0.25%      ±0.05%                                             accuracy for selected settings, test conditions, and
                           D                   .0000001 to 99.99999                      ±0.005      ±0.0025     ±0.0005                                            device under test
                           Q                   .0000001 to 999999.9                      ±0.005      ±0.0025     ±0.0005
                           Z, Rs, Rp,          000.0001 m to 99.99999 M                  ±0.5%       ±0.25%      ±0.05%            Interfaces:                      Standard: USB Host Port, RS-232, Handler, Printer Port
                           ESR,Xs                                                                                                                                   Optional: IEEE-488.2
                           Y, Gp, Bp           00000.01 µS to 9.999999 MS                ±0.5%           ±0.25%           ±0.05%
                           Phase Angle         -180.0000° to +179.9999°                  ±1.8°           ±0.9°            ±0.18°   Charged Capacitor Protection:    8/C for Vmax < 250 V; 2/C for Vmax < 1000V
                                                                                                                                                                    C = Capacitance in farads of the device under test
                           *At optimum test signal levels, frequencies, DUT values and without calibration uncertainty.

                           Capacitance (Cs/Cp), Inductance (Ls/Lp), Resistance (Rs/Rp), Dissipation (D) and                        Measurement Delay:               Programmable from 0 - 1000 ms in 1 ms steps
                           Quality (Q) Factors, Impedance Z , Admittance Y , Phase Angle (0 Equivalent Series
                                                                                          -),
                           Resistance (ESR), Conductance (Gp), Reactance (Xs), Susceptance (Bp)                                    Averaging:                       Programmable from 1 - 1000
                           Note: s = series, p = parallel, ESR equivalent to Rs                                                                                     Median value mode
                                                                                                                                   Data Storage:                    ASCII format
                         Test Frequency:                        Range: 10 Hz to 2 MHz, continuous
                                                                Resolution: 0.1 Hz from 10 Hz to 10 kHz,                           Program Storage:                 Memory internal
                                                                                                                                                                    USB Host Port
                                                                5 digits>10kHz
                                                                                                                                                                    ASCII format
                                                                Accuracy: +/-(0.01% + 0.10Hz)
                                                                                                                                   Calibration:                     Recommended Calibration Interval 1 year
                         Measurement Speed:                     Fast: 25 meas/sec                                                                                   Complete NIST Traceable Calibration using
                                                                Medium: 8 meas/sec                                                                                  QuadTech 7000-09 Cal Kit
                                                                Slow: 1 meas/sec                                                                                    Built-in automatic calibration procedure
                                                                                                                                   Usage & Cal Data:                Displays last calibration date, standard values used in
                         Ranging:                               Automatic, Range Hold or user selectable                                                            calibration and # of hours operation
                                                                                                                                   Self-Test Routine:               Verifies critical instrument operation at power-up
                         Trigger:                               Internal (automatic), External (RS-232,                                                             or when selected from menu
                                                                IEEE-488.2 or Handler interfaces) and Manual
                                                                                                                                   Contact Check:                   Time to detect, 2ms
                         AC Test Signal:                        Voltage:          20 mV to 5.0 V (open circuit)                    Test Terminals:                  Front panel, four terminal (BNC) guarded
                                                                                  up to 500kHz in 5 mV steps
                                                                                                                                   Mechanical:                      Bench mount with tilt bail
                                                                                  20 mV to 1.0 V (open circuit)                                                     Dimensions: (w x h x d): 16 x 6 x 14in
                                                                                  500kHz-1MHz in 5 mV steps                                                                       (410 x 150 x 360mm)
                                                                                  20 mV to 0.5 V (open circuit)                                                     Weight: 17 lbs (8kg) net, 23 lbs (10.5kg) shipping
                                                                                  >1MHz in 5 mV steps                              Environmental:                   Meets MIL-T-28800E, Type 3, Class 5, Style E & F
                                                                Current:          250 µA to 100 mA (short circuit) in                                               Operating: 0oC to + 50o C
                                                                                  50 µA steps                                                                       Humidity: <75% for 11oC to 30oC Operating
                                                                                  Max. Compliance 3V < 500kHz.                                                      Storage: - 10o C to + 60o C
                                                                                                                                   Power:                           · 90 - 250Vac           · 47/63Hz
                         Source Impedance:                      25, 400, 6.4k, or 100k, range dependent
                                                                                                                                                                    · 100W max
                         DC Bias Voltage:                       Internal:         2.0 V
                                                                                                                                   Safety:                          IEC61010-1: 2001
                                                                External:         0 to +/-200V
                                                                                                                                                                    CAT 1, Pollution Degree 2
                         Display:                               LCD Graphics with back light and adjustable contrast
                                                                                                                                   EMC:                             89/336/EEC, 92/31/EEC, 93/68/EEC

                         Result Formats:                        Engineering or scientific notation
                                                                % Deviation from nominal of primary parameter
                                                                Deviation from nominal of primary parameter
                                                                Pass/Fail
                                                                Binning summary
                                                                No Display for maximum throughput

                          Ordering Information
                           7600 Plus Precision LCR Meter                                                Optional Accessories:
                                                                                                        7000-00 Rack Mount Kit                                     7000-06 Axial/Radial Lead Component Test
                           Includes:                                                                    7000-01 BNC Cable Set, 1 meter                             Fixture
                           150905 Instruction Manual                                                    7000-02 BNC Cable Set, 2 meters                            7000-07 Chip Component Test Fixture
                           700700 Power Cord                                                            7000-03 Kelvin Clip Leads                                  7000-09 Calibration Kit
                           P/N N/A Calibration Certificate Traceable to                                 7000-04 Alligator Clip Leads
                           NIST                                                                         7000-05 Chip Component Tweezers


                                                                                  For detailed specifications, visit www.quadtech.com ·
                                          CompuMess Elektronik GmbHpurchase, rent & lease options, call · D-85716 Unterschleißheim
                                                For more information about special · Lise-Meitner-Str. 1
                                               Telefon (089) 32 15 01 - 0 · ·Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
                                                              1-800-253-1230 Fax 1-978-461-4295 · Intl. 1-978-461-2100
                                                                                   5 Clock Tower Place, 210 East, Maynard, MA 01754                                                                                      PN030250/A1