            BHW Medical Lead Acid Battery Chargers
Features
·   100-240 VAC
·   In Case IEC
·   Automatic Fast/Float Function
·   LED Indicators
·   Charges Lead Acid Batteries
·   Optimizes Battery Life
·   Meets Safety Agency Requirements
·   Complies with EMI-RFI Regulations
·   Impact Resistant Polycarbonate Enclosure
·   Private Label Marking Available
·   3 Year Warranty
·   Modified and Custom Designs Also Available

                        Battery        Output       Switchover        Fast Charge         Float Charge         Maximum
    Ault Model        Voltage DC       Amps           Amps             Volts DC             Volts DC            Watts
BHW-06355-0003A           6              3.55             0.205           7.35               6.90                  26
BHW-12200-0003A           12             2.00             0.165          14.70               13.80                 29
BHW-24110-0003A           24             1.10             0.120          29.40               27.60                 32

Input                                                             LED Indicators
·   Voltage              100-240 VAC ±10%                         ·   Indicator #1          On (unit energized)
·   Line Frequency       47 - 63 Hz                                   (Green)               Off (unit de-energized)
·   Current              0.80A - 0.35A (Lower current             ·   Indicator #2          On (battery discharged)
                         with higher voltage)                         Amber)                Off (battery charged
·   Protection           Dual internal primary current            Environment
                         fuse                                     ·   Operating             5° to 40° C with no derating
·   Configuration        In Case IEC320 with ground                   Temperature
Electrical                                                        ·   Storage               -30° to +85° C
·   Topology             Switching - DC battery charger               Temperature
·   Dielectric           4000 VAC, 5656 VDC primary-              ·   Relative Humidity     5% to 95% non-condensing
    Withstand            secondary                                ·   Altitude              0-10,000 feet
                         1500 VAC, 2150 VDC primary-              ·   Cooling               Convectional - non vented case
                         ground                                   Mechanical
                         500 DC secondary-ground                  ·   Case Dimensions       LP7 - Desktop
·   Leakage Current      Less than 0.5mA @ 264 VAC                                          5.08 L x 3.05 W x 1.59 H (in)
                                                                                            129 L x 77 W x 40 H (mm)
·   EMI                  Complies with EMC Directives             ·   Case Material         Black 94V0 polycarbonate
·   CE                   CE Compliant                             ·   Weight                13 ounces, 370 grams
·   MTBF                 100,000 calculated hours                                           (excluding cord)
·   Protection           Foldback overcurrent.
                         Short circuit protection                 ·   Cords and             6 ft., 2 conductor, 18 AWG, Ault
Safety Approvals                                                      Connectors            #3 connector. Other connectors
·   Agency Listings      UL2601, CUL/NRTL for CSA                                           are also available.
                         22.2 #601; TUV for EN60601-1



                                                                       THREE YEAR WARRANTY



                                           CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                             Ault Incorporated, 7105 Northland - 0 · Telefax (089) 32 15 01 55428
                                           Telefon (089) 32 15 01 Terrace, Minneapolis, MN - 11
           Contact Ault Inc. for all your custom design requirements. Phone: 763.592.1900 · Fax 763.592.1911
                                           info@compumess.de · www.compumess.de · www.netzteile.de