BL600
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
BVL
B L 6 0 0 L I T H I U M - I O N FA S T
Fast Charge
CHARGERS Thermistor Number Volts Maximum
Ault Part No. Required of Cells DC **Current Amps
· 100-250 VAC BL600-*-02-170-00-03K No 2 8.4 1.7
· In Case IEC 320 BL600-*-03-314-00-03K No 3 12.6 1.4
· LED Indicators BL600-*-04-100-00-03K No 4 16.8 1.0
· Charges Li-Ion Batteries BL600-*-02-170-00-21K Yes 2 8.4 1.7
BL600-*-03-314-00-21K Yes 3 12.6 1.4
· Optimizes Battery Life
BL600-*-04-100-00-21K Yes 4 16.8 1.0
· Meets Safety Agency Requirements
· Complies with EMI-RFI Regulations
· Impact Resistant Polycarbonate Enclosure **Available Current Rating
2 Cell 0.10 to 1.70A
· Private Label Marking Available
3 Cell 0.10 to 1.40A
· 3 Year Warranty
4 Cell 0.10 to 1.00A
· Modified and Custom Designs Also
Available
Ault Part No. Key
Ault Part No. Key
BL600 * 02 170 00 03 K
Product Denotes Number Fast Charge Denotes standard Connector Manufacturing
Family Safety Timer of Cells Current/Amps or custom Location
Name (with or without requirements
thermistors)
A U LT I N C O R P O R AT E D
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
FAX (1) 763-592-1911 | E-MAIL info@aultinc.com | WEB www.aultinc.com
© Copyright 2002 Ault Inc.
info@compumess.de · www.compumess.de · www.netzteile.de
BL600
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
Input Environmental
Voltage 100-250 VAC -10%, +6% Operating Temperature 0º to 40º C with no derating
Line Frequency 47 - 63 Hz Storage Temperature -30º to +85º C
Current 0.80A - 0.35A (lower with higher voltage) Relative Humidity 5% to 95% non-condensing
Protection Internal primary current fuse Altitude 0-10,000 feet
Inrush limiting
Short circuit protection Cooling Convectional - non vented case
Electrical Mechanical
Topology Switching - DC battery charger Case and Dimensions LP6 - Desktop
4.22L x 2.60W x 1.53H (in)
Dielectric Withstand 3000 VAC, 4243 VDC primary- secondary 107L x 66W x 38H (mm)
EMI Complies with EMC Directives Case Material Black 94V0 polycarbonate
CE CE Compliant Weight 8 ounces, 224 grams (excluding cord)
MTBF 100,000 calculated hours Cords and Connectors 6 ft., 2 conductor, 20 AWG, Ault #3
connector and 6 ft., 3 conductor, 20
MTBF 100,000 calculated hours AWG Ault #21 connector. Other con-
nectors are also available.
Protection Output current limiting
Short circuit protection
Safety Approvals Charger Timers Available for 2, 3, and 4 Cell (*from pg. 1)
Agency Listings CULus1950; TUV EN60950, CE 1 = 3 hr/no thermistor 5 = 3hr hr/ thermistor
2 = 6 hr/no thermistor 6 = 6hr hr/ thermistor
3 = 9 hr/no thermistor 7 = 9hr hr/ thermistor
Input Configuration Please specify the Charger Timer Code in your order
IEC320 Connectors
w/ground
C14
(F)
Configuration: In Case IEC320 with ground
LED Indicators
80% No
Charge Charge Completion Abnormal Battery
Led1 (Yellow) ON ON OFF Blink OFF
Led2 (Green) OFF ON ON Blink OFF
Other Connectors are available by special order
A U LT I N C O R P O R AT E D
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
FAX (1) 763-592-1911 | E-MAIL info@aultinc.com | WEB www.aultinc.com
© Copyright 2002 Ault Inc.