                                               The Compact iX Series represents a new generation of AC/DC power sources that address
                                               the increasing demands on test equipment to perform additional functions at a lower cost.
Combination AC and DC Power                    By combining a flexible AC/DC power source with a high performance power analyzer, the
   Source and Power Analyzer                   Compact iX Series is capable of handling complex applications that have traditionally required
    Replace multiple instruments with a        multiple systems.
    single multifunction unit                  The sleek integrated approach of the Compact iX Series avoids cable clutter that is commonly
                                               found in test systems. All connections are made internally and the need for digital multimeters,
Single & Three Phase Operation                 power harmonics analyzers, and current shunts or clamps is eliminated.
    2253i/iX features a maximum output
                                               Since many components in the Compact iX Series are shared between the AC/DC source and
    of 750VA per phase                         the power analyzer, the total cost of the integrated system is less than the typical cost of a
750 VA to 2250 VA of Output Power              multiple unit system.
    Cost effective power source                For less demanding applications, the Compact i Series provides similar output and transient
                                               capabilities as the Compact iX Series, as well as basic power measurements.
Arbitrary Waveform Generation
    User defined voltage waveform and          Easy To Use Local Controls
    distortion programming (iX Series)         Both the Compact iX and i Series are microprocessor controlled and can be operated from
                                               an easy to use front panel keypad.
Built-in Digital Power Analyzer
    Analyze frequency and time domain of       A large analog control knob can be used to quickly slew output parameters. This knob is
    both voltage and current (iX Series)       controlled by a dynamic rate change algorithm that combines the benefits of precise control
                                               over small parameter changes, with quick sweeps through the entire range.
Rackmountable
    Space-saving rackmount chassis             Applications
                                               With precise output regulation and accuracy, the Compact iX Series AC/DC sources address
Scope Capture Capability                       many application areas for AC and DC power testing. The Compact iX also provides a high
    Built in voltage and current waveform      load current capability, single and three phase output modes (2253 i/iX), and built-in power
    acquisition capability (iX Series)         analyzer measurements. Additional features, including line distortion simulation (LDS) and
                                               arbitrary waveform generation, address product quality and regulatory compliance testing.
Powerful Programing Software
    Powerful, yet easy to use, instrument      Product Evaluation and Test
    control software included (Avionics test   Increasingly, manufacturers of electronic equipment and appliances are required to fully
    software also available)                   evaluate and test their products over a wide range of input line conditions. The built-in output
                                               transient generation and readback measurement capability offers the convenience of an easy
Constant Power Mode                            to use and fully integrated test system.
    Provides increased current at reduced
                                               Adding the -MODE option to the 2253 i/iX allows all three amplifier outputs to be combined
    voltage to maximize efficiency             on phase A output terminal. No external switching or reconnection to the load is required.




www.california-instruments.com                                                                                         ISO 9001:2000
  Compact iX Series - Measurement and Analysis
Avionics                                                                                        The three phase Compact iX (2253i/iX) configuration offers independent
With an output frequency range to 1000 Hz, at up to 300 Vrms, the Compact                       waveform generation on each phase allowing three phase anomalies to be
iX Series is well suited for aerospace applications. Precise frequency control                  programmed and also allows simulation of unbalanced line conditions.
and accurate load regulation are key requirements in these applications.
Four remote control interfaces (IEEE 488, USB, LAN, & RS232) and the SCPI
command language provide for easy integration into existing ATE systems.
The Compact iX Series can eliminate the need for several additional pieces
of test equipment, and occupies a minimal amount of rack space. Options
are available for popular avionics test routines such as: DO-160, Airbus
ABD0100 and AMD24, MIL-STD-704A-F, and Boeing 7E73B-0147. Legacy
programming support is also provided for the replacement of California
Instruments' and third party AC Power Sources.

Remote Control
Standard and optional remote control interfaces allow programming of
all instrument functions from an external computer. The popular SCPI
command protocol is used for programming. Instrument drivers for popular                        Arbitrary Waveform Generation (Compact iX Series only)
programming environments such as National Instruments LabViewTM are                             Using the provided Instrument Control Software, the user also has the
available to speed up system integration.                                                       ability to define arbitrary AC waveforms. The arbitrary waveform method
                                                                                                of data entry provides an alternative method of specifying AC anomalies
                                                                                                by providing specific waveform data points. The Instrument Control
                                                                                                Software includes a catalog of custom waveforms.
                                                                                                Arbitrary waveform capability is a flexible way of simulating the effect of
                                                                                                real-world AC power line conditions in both engineering and production
                                                                                                environments.

                                                                                                AC/DC Transient Generation
                                                                                                The Compact iX and i Series controllers have a powerful AC and DC
                                                                                                transient generation system that allows complex sequences of voltage,
                                                                                                frequency and waveshapes to be generated. This further enhances
                                                                                                the Compact i/iX's capability to simulate AC line conditions or DC
                                                                                                disturbances. When combined with the multi phase arbitrary waveform
                                                                                                capabilities, the AC and DC output possibilities are truly exceptional. In
                                                                                                three phase system configurations, transient generation is controlled
Instrument Control Software                                                                     independently yet time synchronized on all three phases. Accurate
Windows® Instrument Control Software is included with the Compact iX                            phase angle control and synchronized transient list execution provide
and i Series1 . This software provides easy access to the power source's                        unparalleled accuracy in positioning AC output events.
capabilities without the need to develop any custom code. The following
functions are available:
  ·   Steady state output control (all parameters)
  ·   Create, run, save, reload & print transient programs
  ·   Generate & save harmonic waveforms [iX only]
  ·   Generate & save arbitrary waveforms [iX only]
  ·   Measure & log standard measurements
  ·   Capture & display output voltage & current waveforms [iX only]
  ·   Measure, display, print & log harmonic voltage & current measurements [iX only]
  ·   Display bus traffic to & from the AC Source to help you develop your own test programs.
  ·   Toggle between single and three phase output (2253 i/iX only).

1. Requires PC running Windows VistaTM, Windows XPTM, or Windows 2000TM.                        Transient programming is easily accomplished from the front panel where
                                                                                                clearly laid out menu's guide the user through the transient definition
Harmonic Waveform Generation                                                                    process. The front panel allows for transient execution, Start, Stop, Abort
Using the latest DSP technology, the Compact iX Series controller is capable                    and Resume operations.
of generating harmonic waveforms to test for harmonics susceptibility of                        User defined transient sequences can be saved to nonvolatile memory
a unit under test. The Instrument Control Software can be used to define                        for instant recall and execution at a later time. The included Instrument
harmonic waveforms by specifying amplitude and phase for up to 50                               Control Software supports transient definitions using a spreadsheet-like
harmonics. The waveform data points are generated and downloaded by                             data entry grid. A library of frequently used transient programs can be
the Instrument Control Software to the AC source through the Remote                             created on disk.
Interface bus and remain in nonvolatile memory. Up to 50 waveforms can
be stored and given a user defined name for easy recall.




ISO 9001:2000                                                                                                  www.california-instruments.com
        Compact iX Series - Specifications
 Input                                        751i/iX (1 Phase Output)                         1501i/iX (1 Phase Output)                          2253i/iX (1 or 3 Phase Output)
                                            115Vrms +/- 10% or                                115Vrms +/- 10% or                                115Vrms - 230Vrms +/- 10% (Universal Input) - (Output
Voltage:
                                            230Vrms +/- 10%                                   230Vrms +/- 10%                                   rated1500VA@115Vinput. 115V-180Vinputderatedlinearly1500VA-2250VA)
Frequency:                                  47 - 63 Hz                                        47 - 63 Hz                                        47 - 63 Hz
                                            <8.5 Arms @ 115 V                                 <17 Arms @ 115 V                                  <20 Arms @ 115 V
Current:
                                            <4.4 Arms @ 230 V                                 <8.8 Arms @ 230 V                                 <15 Arms @ 230 V
PF:                                         0.97 (typical @ full load)                        0.97 (typical @ full load)                        0.98 (typical @ full load)
Efficiency:                                 80%                                               80%                                               77%
 AC Output
                    High Range:             0 - 300Vrms                                       0 - 300Vrms                                       0 - 300Vrms
Voltage:
                    Low Range:              0 - 150Vrms                                       0 - 150Vrms                                       0 - 150Vrms
                    High Range:             3.25Arms                                         6.5Arms                                            3.25Arms (per phase)
Max. Current:
                    Low Range:              6.5Arms                                          13Arms                                             6.5Arms (per phase)
                    High Range:             10 A Peak                                        20 A Peak                                          10 A Peak (per phase)
Peak Current:
                    Low Range:              20 A Peak                                        40 A Peak                                          20 A Peak (per phase)
AC Power:                                   750VA                                            1500VA                                             750VA (per phase)
Distortion:                                 < 1% THD                                         < 1% THD                                           < 1% THD
 DC Output
                    High Range:             0 - 400Vdc                                       0 - 400Vdc                                         0 - 400Vdc
Voltage:
                    Low Range:              0 - 200Vdc                                       0 - 200Vdc                                         0 - 200Vdc
                    High Range:             1.63Adc                                          3.25Adc                                            1.63Adc (per phase)
Max. Current:
                    Low Range:              1.63Adc                                          1.63Adc                                            3.25Adc (per phase)
High Range:                                 500W                                             1000W                                              500W (per output)
Low Range:                                  250W                                              250W                                              500W (per output)
 Voltage Accuracy/Programming Resolution (AC/DC)
Accuracy (ALC mode ON):                     0.1% FS (from 5V to FS)                          0.1% FS (from 5V to FS)                            0.1% FS (from 5V to FS)
Programming Resolution:                     0.1V                                             0.1V                                               0.1V
 Frequency
Range:                                      16 ­ 1000Hz                                       16 ­ 1000Hz                                       16 ­ 1000Hz
                                            0.01 Hz (16 ­ 81.91 Hz),                          0.01 Hz (16 ­ 81.91 Hz),                          0.01 Hz (16 ­ 81.91 Hz),
Resolution:                                 0.1 Hz (82.0 ­ 819.1 Hz)                          0.1 Hz (82.0 ­ 819.1 Hz)                          0.1 Hz (82.0 ­ 819.1 Hz)
                                            1 Hz (820­ 1000 Hz)                               1 Hz (820­1000 Hz)                                1 Hz (820 Hz ­ 1000 Hz)
Accuracy:                                   0.025%                                            0.025%                                            0.025%
 Measurements
Voltage Accuracy:                           V: 0.1% FS                                        V: 0.1% FS                                        V: 0.1% FS
Current Accuracy:                           C: 0.5% FS                                        C: 0.5% FS                                        C: 0.5% FS
 Mechanical Specifications
Dimensions                                              H: 3.5" (89mm), W: 19" (483mm), D: 23" (584mm)                                          H: 5.25" (133mm), W: 19" (483mm), D: 23" (584mm)
Weight:                                     55 lbs (25kg)                                     66 lbs (30kg)                                     58 lbs (26kg)
Operating Temperature:                      0-40°C                                            0-40°C                                            0-40°C
 Interfaces
USB:                                        Standard                                          Standard                                          Standard
GPIB:                                       Option (i) Std (iX)                               Option (i) Std (iX)                               Option (i) Std (iX)
LAN:                                        Option (iX)                                       Option (iX)                                       Option (iX)
RS232:                                      N/A                                               N/A                                               Standard
Note:      Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase for a sinewave with a resistive
           load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under balanced load conditions only.




www.california-instruments.com                                                                                                                                                            ISO 9001:2000
   Ordering Information                                                                                                                                            Feature Comparison
   Model                         Output Phase                         Max. Current per phase                               Input                             Controller:                            i               iX
                                  Power Output                       Low V range High V range                              Voltage
                                    AC                               AC      DC      AC      DC                                                              AC Mode                                x                x
   751i/iX                        750 VA  1                          6.5      1.63    3.25    1.63                       115/230V                            DC Mode                                x                x
   1501i/iX                        1.5 kVA              1          13.0               1.63           6.5        3.25     115/230V                            AC+DC Mode                                              x
   2253i/iX                      2.25 kVA              3/1  1
                                                                     6.5              3.25           3.25       1.63     115-230V                            Transient
1. With -MODE Option                                                                                                                                         Programming                            x                x
                                                                                                                                                             Arbitrary
        Constant Power Chart                                                                                                                                 Waveforms                                               x
                                                                                                                                                             Measurements                           x                x
             100%
 Current                                                                                                                                                     Harmonic
 (RMS) 90%                                                                                                                                                   Measurements                                            x
               76%
                                                                                                                                                             Waveform
               50%                                                                                                                                           Acquisition                                             x
                                                                                                                        Full
                                                                                                                       Power
               20%                                                                                                                                       Model:
                                                                                                                                                            Refer to table shown for model numbers
                 0%                                                                                                                                         and configurations.
                                   13%            25%                            50%                          76%                 100%
                                                                                                                Voltage (RMS)                            Supplied with:
  Note: Constant power mode provides increased current at reduced voltage. Maximum available current shown.                                                  User Manual, Programming Manual,
                                                                                                                                                             Software (all on CD ROM)
                                                                                                                                                         Options
    Compact 750/1501 i/iX Rear Panel                                                                                                                     -160               RTCA/DO-160D/E and EUROCAE test
                                                                                                                                                                            firmware. Refer to -160 option data
                                                                                                                                                                            sheet for details.
                                                                                                                                                         -704               Mil Std 704D/E test firmware
                                                                                                                                                         -704F              Mil Std 704 Revision A-F test
                                                                                                                                                                            firmware/software.
                                                                                                                                                         -ABD               Airbus Directive 0100.1.8 tests.
                                                                                                                                                         -ABL               ABLE Command
                                                                                                                                                         -AMD               Airbus AMD-24C Test
                                                                                                                                                         -B787              Boeing 787B3-0147 tests.
                                                                                                                                                         -EXS               External Sync Input.
                                                                                                                                                         -LAN               Ethernet Lan Inter face (RJ45
                                                                                                                                                                            Connector) (iX Only).
    Compact 2253 i/iX Rear Panel                                                                                                                         -LF                Limits maximum frequency to
                                                                                                                                                                            500Hz.
                                                                                                                                                         -LKM               Clock/Lock Master
                                                                                                                                                         -LKS               Clock/Lock Auxiliary
                                                                                                                                                         -MODE              Allows all three amplifier outputs
                                                                                                                                                                            to be combined on phase A output
                                                                                                                                                                            terminal. No external switching or
                                                                                                                                                                            reconnection to the load is required
                                                                                                                                                                            (2253 i/iX only).
                                                                                                                                                         -RMS               Rackmount Slides (2253 Only)
                                                                                                                                                         -RPF               Remote programming frequency
                                                                                                                                                                            (0-10 V DC).
                                                                                                                                                         -RPV               Remote programming voltage
                                                                                                                                                                            (0-10 V DC).
                                                                                                                                                         -WHM               Watt-hour measurement.

Note:        Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase for a sinewave with a resistive
             load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under balanced load conditions only.



   9689 Towne Centre Drive, San Diego,GmbH · Lise-Meitner-Str. 1 · D-85716 (858) 677-0940 l sales@calinst.com
      CompuMess Elektronik CA 92121-1964 l (858) 677-9040 l FAX: Unterschleißheim
   © Copyright 2007, California Instruments Corp.                                        Specifications subject to change without notice                                Printed in the USA                         CiXDS 09/07
                Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
                                                                                www.california-instruments.com