In today's environment of rising energy costs and green initiatives, understanding your energy profile is more important than ever. Where and when electricity is consumed is an essential part of any energy management                         Energy Platform Report Writer software (EPRW) is included with every EP1.
program - "What gets measured gets done". Energy PlatformTM EP1 from Dranetz-BMI is an innovative and essential tool for any electrical energy monitoring application. Whether you want to understand your utility costs, improve                EPRW is unlicensed software that summarizes your survey, producing easy to read,
efficiency, install energy savings devices, explore alternative energy solutions or even determine your carbon footprint, Energy Platform provides the essential monitoring tools to meet your energy monitoring needs. Energy Platform's        user selectable reports. Voltage, Current, Watts, VA, VAR, PF, harmonics, Demand,
                                                                                                                                                                                                                                                 Energy and many other parameters can be trended to create your own custom
1/4 VGA color touch display, AC and DC capabilities, automatic setups, easy to read reports and EPRW report writer software provide a simple to use, yet powerful tool for any application.
                                                                                                                                                                                                                                                 report. Or, just use the automatic feature and let EPRW quickly generate your
                                                                                                                                                                                                                                                 report without any setups. The Energy Audit feature summarizes your energy
                                                                                                                                                                                                                                                 survey, including your basic billing parameters such as time of use (peak,
Colorful, Easy To Read Demand & Energy Reporting
Ease of use is important to every application. Even the best of instruments                                       ENERGY PLATFORM                                                                                                                partial-peak, off-peak times), peak demand, energy cost and Carbon Footprint
                                                                                                                                                                                                                                                 calculations. Reports are created in a RTF format so you can easily edit your

                                                                                                                                                       EP1
fall short if the user can't easily and efficiently view important results. Energy                                                                                                                                                               report in any text editor. A data export feature is available to bring your data to
Platform's user interface displays Demand and Energy reports in an easy to                                                                                                                                                                       other software applications. Data can be exported to a .csv file format for use in
understand, color coded format. All pertinent information such as V, A, W,                                                                                                                                                                       Microsoft excel or other compatible software packages.
Demand & Energy and more is on screen with each square showing real time
                                             readings and computations. Results are                                                                                                                                                              For more advanced applications, EP1 is fully compatible with our award winning
                                             color coded to easily identify if a                                                                                                                                                                 DranView (optional) software that adds advanced analysis in an easy to use
                                             parameter has exceeded any triggered                                                                                                                                                                software package. DranView is a powerful tool that makes data analysis easy.
                                             conditions. A green square means the                                                                                                                                                                DranView has advanced features such as bookmarks, zooming, rubber banding,
                                             parameter is within limits. Blinking Red                                                                                                                                                            balloon annotations, math functions
                                             or Yellow means the parameter has                                                                                                                                                                   and can even include your company's
                                             exceeding your monitoring limits. It's                                                                                                                                                              logo. The built in Rescue Kit can
                                             that simple!                                                                                                                                                                                        help undo monitoring mistakes such
                                                                                                                                                                                                                                                 as reversed CTs, wrong scale factors,
                                                                                                                                                                                                                                                 wrong instrument time and more.
                                                                                                                                                                                                                                                 DranView's report writer has a variety
                                                                                                                                                                                                                                                 of report functions available to meet
                                                                                                                                                                                                                                                 any application and now includes the
                                                                                                                                                                                                                                                 Energy Audit report also available in EPRW.
Carbon Footprint                                                                                                                                                                                                                                 DranView is used world-wide by thousands
Being environmentally friendly is not just a catch                                                                                                                                                                                               of power professionals to analyze data taken
phrase but is a corporate obligation in many cases.                                                                                                                                                                                              on Dranetz-BMI products.
In regards to energy consumption, Carbon Footprint
is the total amount of greenhouse gas emissions
produced generating the electricity consumed. Energy                                    No Learning Curve - Automatic Setups                                        Power Surveys                                                                Point of Utilization Monitoring
Platform's Carbon Footprint report computes the (electrical)                            Getting the job done and getting it done right are of utmost                Energy Platform measures more than 50 electrical parameters including        Measuring a single phase device such as a refrigerator, air conditioner, etc may
Carbon Footprint for measured loads based upon your real                                importance in any application. Proper instrument setup is essential         the traditional power parameters (V, I, W, PF, etc), Demand/Energy,          seem simple but there are typically CT and wiring challenges without breaking
monthly energy usage. Results are displayed in your choice of                           in making sure your data is correct, made even more important in            harmonics (Thd, TID, individual harmonics) and advanced parameters           the circuit, or making custom cables. Dranetz-BMI's new Point Of Utilization
pounds or Kilograms of CO2. Many utilities publish CO2                                  common EP1 applications such as energy benchmarking /reduction              such as Forward and Reverse Energy. Most parameters can be metered           Monitoring Adapter or PUMA does the work for you allowing for easy and safe
emission details and provide a constant multiplier representing                         and alternative energy where the results are critical in determining        in real time, trended and triggered in order to know when your limits        measurement of any single phase load. PUMA is an in line adapter that allows
an average based upon the various generation methods used.                              next steps. Energy Platform's Automatic Setup makes for a produc-           have been exceeded, giving you a chronologic summary of triggers that        for simple connection to Energy Platform or other Dranetz-BMI product. Simply
This is used by EP1 to compute actual values based upon your                            tive tool right out of the box since there is no learning curve. Simply     occur while monitoring.
energy usage.                                                                                                                                                                                                                                    plug the line cord of your device into PUMA and plug PUMA into any standard AC
                                                                                        connect EP1 to your load, energize your circuit then select Automatic                                                                                                                                   receptacle. PUMA is available in
                                                                                                                                                                    Advanced demand and energy consumption and reporting are key
                                                                                        Setup to have the EP1 do the work for you. It identifies the circuit                                                                                                                                    two versions to accommodate the
                                                                                                                                                                    capabilities but Energy Platform doesn't stop there. Energy Platform
                                                                                        type, nominal voltage and current in one step. Detected load details
                                                                                                                                                                    also has Power Quality features and can detect cycle by cycle changes in                                                    various plug types from around
                                                                                        are displayed on screen for you to review, then simply click OK to
                                                                                                                                                                    RMS Voltage using industry standard settings. EP1 measures every                                                            the world. The US version
Harmonics                                                                               start metering and monitoring.
                                                                                                                                                                    voltage cycle and can record when any one cycle exceeds limits.                                                             (shown) supports the standard
As the sensitivity of power electronics increases, equipment ranging from HVAC          For those who wish to create their own triggers, recording intervals        Triggers are chronologically displayed in an easy to read textual format                                                    120VAC North American plug type.
systems, personal computers and copiers to computerized process equipment               or any other settings to better meet their application, an interactive      that shows the time stamp, Sag or Swell characterization, duration and                                                      An international version that has
and manufacturing systems are susceptible to harmonic pollution. In fact,               Wizard setup is available to customize EP1 to meet virtually any            min/max while out of limits. Voltage and Current waveform snapshots are                                                     different enclosure supports most
harmonics can cause small, almost imperceptible variations in performance that          application. Users can create custom setup templates for any variety        also available and can be recorded on a periodic basis. Snapshots can
                                                                                                                                                                                                                                                                                                worldwide 230VAC plug types for
                                          aggregate to affect significant long-term                                             of applications they will                                                    be used to visually assess the
                                          damage. Current harmonics generated by                                                                                                                                                                                                                use in virtually every other part of
                                                                                                                                encounter, store them to                                                     quality of supply or for use with
                                          a source can pollute the entire power                                                 Compact Flash memory and                                                     DranView software. For more                                                        the world. Regardless of version,
                                          system. The Energy Platform captures                                                  recall them in the field for fast                                            advance Power Quality applica-                                                     PUMA comes complete with
                                          detailed harmonics, interharmonics                                                    and convenient setup of EP1 to                                               tions that require recording of                                                    standard banana jacks voltage
                                          and subharmonics in accordance to                                                     meet that specific application.                                              waveshapes, transients and                                                         connections and Dranetz-BMI
                                          IEC61000-4-7 to effectively troubleshoot                                                                                                                           other important Power Quality                                                      compatible current cables ready
                                          the complex problems caused by these                                                                                                                               parameters consider the                                                            to plug into Energy Platform.
                                          events.                                                                                                                                                            PowerXplorer, PowerGuide or
                                                                                                                                                                                                             PowerVisa from Dranetz-BMI.
ENERGY PLATFORM EP1
 SPECIFICATIONS
Measured Parameters                                                                            Optional Accessories
Volts, Amps, Watts, Volt-Amperes, Volt-Amperes Reactive, True                                  Energy Platform packages include everything you need to
Power Factor, Displacement Power Factor                                                        get started and includes a CFmemory card, EPRW software,
Demand, Energy, Forward Energy, Reverse Energy,                                                voltage cables, clamp-on or Flex CTs. Other accessories
Harmonic Power
                                                                                               available separately:
Harmonics & Interharmonics Per IEC 61000-4-7
                                                                                               DranView Software
THD/Harmonic Spectrum, TID/Interharmonic Spectrum (V, I, W)
                                                                                                  DranView PRO
to 63rd
                                                                                                  DranView Enterprise
Crest Factor, K Factor, Transformer Derating Factor, Telephone
                                                                                               Point of Utilization Monitoring Adapter (PUMA)
Interference Factor
                                                                                                  In-line adapter to easily to measure V & I for single
                                                                                                  phase loads
Measurement Specifications                                                                     Clamp-On Probes:
(4) Voltage Channels, 1-600 Vrms, AC/DC, 0.1% rdg +                                               Model TR2501; 100ma ­ 1.2A
0.05% FS, 256 s/c, 16 bit ADC.                                                                    Model TR-2510A; 0.1A ­ 10A
CH A, B, C Single Reference, Ch D Differential.
                                                                                                  Model TR2550A; 1A ­ 100A
(4) Current Channels, 1-6000 Arms, CT Dependent, AC/DC,
                                                                                                  Model TR2500; 10A ­ 500A
256 s/c, 0.1% rdg + CT's, 16 bit ADC
                                                                                               Flexible Current Probes
W, VA, VAR: 0.2% rdg, +/- 0.1% FS. Per phase + CT's
                                                                                                  DRANFLEX3000XL /24 /36 /48; 30 /300 /3000A available in
Frequency Range: 45-65 Hz Phase Lock Loop,
                                                                                                  24", 36", 48"
10 mHz Resolution
                                                                                                  DRANFLEX6000XL /24 /36 /48; 60 /600 /6000A available in
Vthd, Ithd: 1% rdg, +/- 0.05% FS. Per channel + CT's
                                                                                                  24", 36", 48"
                                                                                                  DRANFLEX3003XL /24; 30 /300 /3000A, 24: 3 phase
General Specifications                                                                            (3 Flex CT's)
Display: 1/4 VGA Color Touch Interface                                                            Flex CT power supplies sold separately
AC Power Supply/Charger: 90-264VAC, 47-63Hz; 20W max.                                          DC/AC Hall Effect CTs
2hr Rechargeable Battery.                                                                         PR150/SP1/SP2; AC or 9V battery power
Size: (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3cm);                                           PR1500/SP7/SP8; AC or 9V battery power
Weight: 3.8 lbs (1.8kg)                                                                           Power supplies sold separately
Operating temperature: 0 to 50 degrees C;                                                      BP-PX5; Field Replacement Battery Pack
Storage temperature: -20 to 55 degrees C;                                                      XBC-PX5; External Battery Charger
Humidity: to 98% non-condensing.
                                                                                               SCC-4300; Soft Carrying Case
Removable Memory: Compact Flash, up to 32GB, 4GB min.
                                                                                               RSC-4300; Rugged Shipping Container
                                                                                               ENCL-HH; Weather Resistant Enclosure
EP1 Packages                                                                                   FlashReader-USB; US CF Memory Card Reader
EP10-4  EP1, soft case, voltage cable set, EPRW software,
        CF Card, 4x TR2510 clamp-on CT, power supply
EP500-4 EP1, soft case, voltage cable set, EPRW software,
        CF Card, 4x TR2500 clamp-on CT, power supply.
EP550-4 EP1, soft case, voltage cable set, EPRW software,
        CF Card, 4x TR2550 clamp-on CT, power supply.
EPFLEX3 EP1, soft case, voltage cable set, EPRW software,
        power supply, CF Card 4 x 3000A Flex CT with                                                                                                                An Innovative and Essential Tool
        power supply (1 x DranFlexXL3003XL + 1 x
        DranFlex3000XL)                                                                                                                                     for any Electrical Energy Monitoring Application

              CompuMess Elektronik GmbH
     Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
   Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
       info@compumess.de · www.compumess.de
                     www.netzteile.de

                                  1.800.372.6832                    sales@dranetz-bmi.com
                                  tel 732.287.3680 · fax 732.248.1834 · 1000 New Durham Road · Edison, New Jersey 08818 USA
                                  Energy Platform and DRAN-VIEW are trademarks of Dranetz-BMI. ©2009 Dranetz-BMI. All rights reserved.
dranetz-bmi.com                   Printed in the United States. Specifications are subject to change without notice.