                                                                              DC Power Supplies
                              By California Instruments                             KDC Series


·   Compact DC Power
    Uses less rack space compared to
    other DC supplies of similar power
    level.
·   5 to 15 KW & Beyond
    Modular design supports
    5, 10 and 15 kW versions.
    Higher output using parallel opera-
    tion of multiple chassis.
·   Protection Modes
    User selectable constant voltage trip
    or constant current modes.
·   Built-in Measurements
    Voltage, current and power
    readback capability standard.
·   Transient Programming
    User defined output sequence pro-
    gramming from the front panel.
·   Standard RS-232C Interface and
    Optional GPIB.
    Instrument drivers and software
    support for easy system integration.


Compact Power                          Advanced Control                       Applications
The KDC Series packs up to 15 kW       The KDC Series has three               The advanced features and
of DC power in a 5.25" (3U) chassis.   operational modes: constant            capabilities of the KDC Series make
Despite the high power density of      voltage, constant current and          the power supply suitable for
the design, the KDC Series provides    constant power. The constant           challenging test applications such
a low noise, stable output. The DC     voltage and constant current modes     as: fuel testing, super capacitor
voltage ranges are 30 V to 600 Vdc,    can be configured for voltage fold     characterization, and other high
which supports a wide range of         back or shutdown when the              technology applications.
applications.                          programmed current limit set point     The availability of RS-232, GPIB/
The KDC Series comes with an RS-       is reached.                            IEEE-488, and isolated analog
232 as the standard remote             The transient program function         interfaces make the KDC easy to
programming interface. The IEEE-       allows users to define up to 100       integrate into ATE and other
488/GPIB & isolated analog             output sequences. Each sequence        automated systems. The KDC
interfaces are optional. The KDC       can contain up to six parameters.      Series is designed to accept 208,
Series continuously measures           Parameters include: voltage set        400 and 480V line-to-line AC inputs.
output voltage, current, peak          point, slew rate, current set point,
current, and power.                    dwell time, and trigger. A graphical
                                       user interface is included with each
                                       KDC Series Power Supply. This
                                       powerful interface software allows
                                       users to generate automated test
                                       routines in minutes. .
      CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
        Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
  KDC Series - Controller Capabilities
All KDC Series Power Supplies use an advanced DSP
based controller with a menu driven user interface. This
controller provides capabilities not typically found in
most DC supplies.
Output Sequencing: Time driven output changes can
be programmed, stored and executed under program
control. Events include steps, sweeps, drops and
surges of voltage and/or current. This allows a variety of
power conditions and DC tests to be set up and ex-
ecuted from the front panel. Multiple sequences can be
stored in nonvolatile memory for quick recall.
Parallel Mode: Multiple KDC units can be combined to
provide high output current capability using a master/
auxiliary combination.
Output Impedance: A programmable output impedance
function allows simulation of DC source impedance as a
function of load conditions.                                      Graphical user interface DC supply control program.
Remote Control: The included KDC GUI program
provides easy access to these and other KDC controller
capabilities using a Windows PC with the standard RS-
232C or the optional IEEE-488/GPIB interface.




  KDC Series - Models1
                                    Output                                                       Output

 Model            Voltage        C urrent        R MS N oise        Model           Voltage      C urrent    R MS N oise

 KD C 30-167     0-30            0-167              15mv            KD C 150-33     0-150        0-33           25mv

 KD C 30-333     0-30            0-333              15mv            KD C 150-66     0-150        0-66           25mv

 KD C 30-500     0-30            0-500              15mv            KD C 150-100    0-150        0-100          25mv

 KD C 40-125     0-40            0-125              15mv            KD C 300-17     0-300        0-17           100mv

 KD C 40-250     0-40            0-250              15mv            KD C 300-33     0-300        0-33           100mv

 KD C 40-375     0-40            0-375              15mv            KD C 300-50     0-300        0-50           100mv

 KD C 50-100     0-50            0-100              15mv            KD C 400-12     0-400        0-12.5         100mv

 KD C 50-200     0-50            0-200              15mv            KD C 400-25     0-400        0-25           100mv

 KD C 50-300     0-50            0-300              15mv            KD C 400-37     0-400        0-37           100mv

 KD C 80-62      0-80            0-62               25mv            KD C 600-8      0-600        0-8            250mv

 KD C 80-125     0-80            0-125              25mv            KD C 600-17     0-600        0-17           250mv

 KD C 80-187     0-80            0-187              25mv            KD C 600-25     0-600        0-25           250mv

 KD C 100-50     0-100           0-50               25mv

 KD C 100-100    0-100           0-100              25mv

 KD C 100-150    0-100           0-150              25mv

Note 1: Contact factory for availability of models with output voltage ranges not listed here.
 KDC Series - Specifications

Electrical                                                 Protection
Output                                                      Over temperature, short circuit, over current protec-
                                                            tion, open sense.
Power
  Maximum               5, 10 or 15 KW                     Controls and Indicator
Voltage
                                                           Controls
  Line Regulation:      < 0.1% of Range                     Dual digitally encoded rotary knobs, Function keys,
  Load Regulation:      < 0.1% of Range                     Output on/off, Power on/off
  Accuracy:             ± 0.05% Setting + 0.1% Range
  Transient Response:   Voltage will recover to within     Indicators
                        2% of voltage range within 2         Display:              Alphanumeric LCD, dual line.
                        msec for a 30 % load step.           LED's for:            Output on/off, CC mode, CV
  Stability:            ± 0.05% of max. rating per 8                               mode, CP mode and Remote.
                        hours after 30 mins. warm-up
                        at fixed line, load and tempera-   Remote Control
                        ture.                              A standard RS-232C is included with all KDC Series DC
Current                                                    Power Supplies. An optional GPIB/IEEE-488 with an
                                                           isolated analog interface is available as well.
  Line Regulation:      < 0.1% of Range
  Load Regulation:      < 0.1% of Range                    RS-232C / RS-485 - Standard
  Accuracy:             ± 0.05% Setting + 0.1% Range        9 pin D-shell connector, 115200 baud max., SCPI
  Stability:            ± 0.05% of setting after 8 hour     syntax.
                        warm-up at fixed line, load and
                                                           -IF Option:
                        temperature.
                                                           IEEE-488 Interface
Input
                                                             IEEE-488 (GPIB) talker listener.
  Voltage:              208 - 10 % to 230 +10% VAC
                                                             Subset:              AH1, C0, DC1, DT1, L3, PP0,
                        400 ± 10 % VAC
                                                                                  RL2, SH1, SR1, T6
                        480 ± 10 % VAC
                                                                                  IEEE-488.2 SCPI syntax
                        All inputs are L-L, 3 phase, 3-
                        wire plus safety ground. Input     Isolated Analog Interface:
                        rating must be specified at          Voltage Control:      0-10 VDC, 0-5 VDC or R for 0-
                        time or order.                                             100% range
  Current RMS:          Typical RMS current per              Current Control:      0-10 VDC, 0-5 VDC or R for 0-
                        phase at low line input voltage.                           100% range
                                Power Level                  I/O Connectors:       Analog I/O, 15 Pin D-sub,
                        Vlow    5 kW 10 kW 15 kW                                   isolated
                                                                                   Auxiliary I/IO, 9 Pin D-sub, non-
                        187 V: 27 A       54 A    81 A
                                                                                   isolated
                        360 V: 15 A       30 A    45 A
                                                             Functions:            Remote output on/off
                        432 V: 12 A       24 A    36 A                             Trigger input
  Power Factor:         > 0.65                                                     Function strobe out
                                                                                   Volt monitor out
  Efficiency:           > 85 % at full load.
                                                                                   Current monitor out
Measurements
Voltage
  Accuracy:             0.05% + 0.1% Full Scale
  Resolution:           0.025% Full Scale
Current
  Accuracy:             0.1% + 0.2% Full Scale
  Resolution:           0.025% Full Scale
Power
  Accuracy:             0.2% + 0.3% Full Scale
  Resolution:           0.05% Full Scale
  KDC Series - Specifications

Environmental                                             Mechanical
Temperature Coefficient                                   Dimensions
  Voltage set point:     0.02%/°C of V Range                Height:                5.25" / 133.35 mm
  Current set point:     0.03%/°C of I Range                Width:                 19" / 482.6 mm
Ambient Temperature                                         Depth:                 22.19" / 563.3 mm excl. bus
                                                                                   bars and cover
  Operating:             0° to 40° C / 32° to 104° F
                                                                                   24.74" / 628.4 mm incl. bus
  Storage:               -40° to 75° C / -40° to 167° F
                                                                                   bars and cover
Humidity
                                                          Weight                   15 KW           10 KW             5KW
  Operating:             0 to 80% RH, non condensing
                                                            Net:                   84 lbs.         70 lbs.           56 lbs.
Cooling                                                                            38.1 Kg         32 Kg             25.4 Kg
  Forced air, front intake, rear exhaust.                   Shipping (approx.):    110 lbs.        96 lbs.           82 lbs.
                                                                                   50 Kg           44 Kg             37.2 Kg
                                                          Rack Mounting
                                                            Unit must be supported by shelf or brackets when
                                                            mounted in 19" cabinet. No provisions for rack slides
                                                            are made on the instrument.




  KDC Series - Ordering Information

                                                          Ordering Examples:
Ordering Information
                                                          Model                    Description
Model                                                     KDC 50-200-208           Output voltage 50 Vdc, maxi-
All KDC Series model numbers specify voltage and                                   mum current is 200 Adc, line
current range.                                                                     input is 208 V line to line, three
KDC VVV-CCC-LLL-XX.                                                                phase. Includes standard RS-
                                                                                   232C remote interface.
        VVV = Voltage
                                                          KDC 80-187-400-IF        Output voltage 80 Vdc, maxi-
        CCC = Current
                                                                                   mum current is 187 Adc, line
        LLL = Input Line Voltage                                                   input is 400 V line to line, three
        XX = Options                                                               phase. Includes optional IEEE/
Refer to table shown for model numbers and configura-                              RS-232C and analog interfaces.
tions.                                                    XDS Series Products
Supplied with                                             For applications requiring only basic controller functions
User manual and programming manual on CD ROM.             but similar power levels and voltage ranges as the KDC
                                                          Series, refer to the Argantix XDS Series.
Windows GUI software on CD ROM.
RS-232C serial cable.
Options
-IF         GPIB / IEEE-488 interface and analog
            remote voltage programming option.
-400        400-440 Volt line to line, three phase AC
            input option.
-480        432-528 Volt line to line, three phase AC
            input option.



                                  For more information call:
                                  TEL: 858 404-6936 Email: sales@argantix.com                 © Copyright 2003, Argantix. San Diego, California, USA
                                                                                              Specifications subject to change without notice
                                  FAX: 858 677-0940 Web: www.argantix.com                     Printed in the USA                       DS KDC 02/05