MPM-04V Series
Compact, Board Mount 4W
Ultra-Wide Input Range
AC/DC Power Supplies
Key Features: Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
· 4W Output Power
Input
· Universal 90-305 VAC Input Parameter Conditions Min. Typ. Max. Units
· Miniature Size 90 305 VAC
Input Voltage Range
· EN 60950 Approved (UL) 120 430 VDC
· Meets IEC Safety Class II Input Frequency 47 440 Hz
Input Current See Model Selection Guide
· Single and Dual Outputs
115 VAC 15.0
· Meets EN 55022 B Inrush Current A Pk
230 VAC 25.0
· >350 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
EMC Meets EN 55024
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy See Note 2 ±2.0 %
3.3V Output, VIN = Min to Max ±0.5
Line Regulation, See Note 3 %
5V to 24V Output, VIN = Min to Max ±0.2
Load Regulation, Single Output 3.3V output, IO = 0% to 100% ±1.5 %
Load Regulation, Single Output 5V to 24V output, IO = 0% to 100% ±0.5 %
Load Regulation, Dual Output Vout 1, IO = 10% to 100% ±0.5 %
Load Regulation, Dual Output Vout 2, IO = 10% to 100% ±5.0 %
Single 3.3V & 5V Outputs 150.0
Ripple/Noise (20 MHz) mVP-P
All Other Models 100.0
Hold-Up Time 115 VAC 15 mSec
Temperature Coefficient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, See Note 4 Continuous (Autorecovery)
Overload Protection 105 120 % of IO
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) EN 61000-4-2 Level B
RF Field Susceptibility EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV
Surge EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 132 kHz
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street Operating Temperature Range Ambient-40 +25 +70 °C
Suite D Storage Temperature Range -40 +125 °C
Stoughton, MA 02072 Cooling Free Air Convection (See Derating Curve)
USA Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226 Case Size 1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
F: (781) 344-8481 Case Material Non-Conductive Plastic & Fiberglass (UL94-V0)
E: sales@micropowerdirect.com Weight 0.91 Oz (26g)
W: www.micropowerdirect.com Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 350 kHours
Safety Standards UL 60950, EN 60950
Safety Approvals UL, cUL; File No. E245422
Safety Class IEC 61140 Class II
www.micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output 1 (See Note 1) Output 2 (See Note 1) Maximum
Model Maximum Voltage Maximum Output Efficiency
Current (A) Voltage Current (mA) Current (mA)
Number Cap. Load Cap. Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (µF)
(VDC) Max. Min. (µF) (W)
MPM-04SV-03 0.075 0.055 3.3 1.200 0.0 14,000 3.96 70
MPM-04SV-05 0.075 0.055 5.0 800 0.0 8,000 4.0 72
MPM-04SV-08 0.075 0.055 8.0 500 0.0 2,700 4.0 74
MPM-04SV-09 0.075 0.055 9.0 444 0.0 2,400 4.0 75
MPM-04SV-12 0.075 0.055 12.0 333 0.0 1,000 4.0 76
MPM-04SV-14 0.075 0.055 14.0 286 0.0 750 4.0 76
MPM-04SV-15 0.075 0.055 15.0 267 0.0 700 4.0 76
MPM-04SV-24 0.075 0.055 24.0 167 0.0 220 4.0 77
MPM-04DV-0503 0.085 0.065 +5.0 +600 0.0 5,600 +3.3 +150 0.0 4,700 3.5 72
MPM-04DV-0805 0.085 0.065 +8.0 +375 0.0 1,000 +5.0 +120 0.0 4,700 3.6 74
MPM-04DV-1205 0.085 0.065 +12.0 +250 0.0 330 +5.0 +120 1.2 4,700 3.6 75
Notes:
1. For dual output models, Output 1 is +Vo and Output 2 is +Vr. A Mechanical Dimensions
47 µF/25V ceramic capacitor must be connected from +Vo (pin 12)
of dual output models to Common (pin 11). Without this capacitor, the
unit may not meet all specifications.
2. For dual output models, output voltage accuracy is specified as ±2%
for +Vo and ±5% for +Vr.
3. For dual output models, line regulation is specified as ±0.2% for +Vo
and ±3% for +Vr.
4. Output short circuit protection is provided by a "hiccup mode" circuit.
The unit recovers automatically when the fault condition is removed.
5. Operation at under no load conditions will not damage these units.
It is recommended that the minimum load values in the table above
be used.
6. It is recommended that a fuse be used on the input of a power
supply for protection. For the MPM-04V series, a 1A/250 VAC
slow blow should be used.
Pin Connections
Pin Single Dual Pin Single Dual
1 NC NC 10 NC +Vr
7 AC-Neutral 11 -Vo Common
9 AC-Line 12 +Vo +Vo
NC = No Connection Notes:
· All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
Derating Curve, Vin = 90-280 VAC Derating Curve, Vin = 280-305 VAC
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 · TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail: sales@micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de