MPM-04 Series
Compact, Board Mount 4W
Single And Dual Output
AC/DC Power Supplies
Key Features: Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
· 4W Output Power
Input
· Miniature Size
Parameter Conditions Min. Typ. Max. Units
· Universal 90-264 VAC Input 90 264 VAC
Input Voltage Range
· EN 60950 Approved 120 370 VDC
· Meets IEC Safety Class II Input Frequency 47 440 Hz
· Single and Dual Outputs Input Current See Model Selection Guide
115 VAC 15.0
· Meets EN55022 B Inrush Current A Pk
230 VAC 25.0
· >350 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
EMC Meets EN55024
Safety Ground Leakage Current 264 VAC 0.30 mA
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy, Note 2 ±2.0 %
Line Regulation, Note 3 VIN = Min to Max ±0.2 %
Load Regulation, Single Output 3.3V to 9V output, IO = 0% to 100% ±1.0 %
Load Regulation, Single Output 12V to 24V output, IO = 0% to 100% ±0.5 %
Load Regulation, Dual Output Vout 1, IO = 10% to 100% ±0.5 %
Load Regulation, Dual Output Vout 2, IO = 10% to 100% ±5.0 %
Ripple (20 MHz) Note 4 100.0 mVP-P
Noise Note 4 150.0 mVP-P
Hold-Up Time 115 VAC 15 mSec
Temperature Coefficient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, Note 4 Continuous (Autorecovery)
Overload Protection 105 120 % of IO
General
Parameter Conditions Min. Typ. Max.
Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) IEC/EN 61000-4-2 Level B
RF Field Susceptibility IEC/EN61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Level 3 2 kV
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 132 kHz
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street
Operating Temperature Range Ambient-40 +25 +70 °C
Suite D
Storage Temperature Range -40 +125 °C
Stoughton, MA 02072
Cooling Free Air Convection (See Derating Curve)
USA
Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226
F: (781) 344-8481 Case Size 1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
E: sales@micropowerdirect.com Case Material Non-Conductive Plastic& Fiberglass (UL94-V0)
W: www.micropowerdirect.com Weight 0.91 Oz (280g)
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 350 kHours
Safety Approvals IEN 60950, IEC 60950
Safety Class IEC 61140 Class II
www.micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output 1 (See Note 1) Output 2 (See Note 1) Maximum
Model Maximum Voltage Maximum Output Efficiency
Current (A) Voltage Current (A) Current (A)
Number Cap. Load Cap. Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. (A) Min. (%) (µF)
(VDC) Max. (A) Min. (%)
(µF) (W)
MPM-04S-03 0.075 0.055 3.3 1.200 0.0 14,000 3.96 70
MPM-04S-05 0.075 0.055 5.0 800 0.0 8,000 4.0 72
MPM-04S-08 0.075 0.055 8.0 500 0.0 2,700 4.0 76
MPM-04S-09 0.075 0.055 9.0 444 0.0 2,400 4.0 76
MPM-04S-12 0.075 0.055 12.0 333 0.0 1,000 4.0 76
MPM-04S-14 0.075 0.055 14.0 286 0.0 750 4.0 76
MPM-04S-15 0.075 0.055 15.0 267 0.0 700 4.0 76
MPM-04S-24 0.075 0.055 24.0 167 0.0 220 4.0 77
MPM-04D-0503 0.085 0.065 +5.0 +600 0.0 5,600 +3.3 +150 0.0 4,700 3.5 73
MPM-04D-0805 0.085 0.065 +8.0 +375 0.0 1,000 +5.0 +120 1.0 4,700 3.6 76
MPM-04D-1205 0.085 0.065 +12.0 +250 0.0 330 +5.0 +120 1.0 4,700 3.6 77
Notes:
1. For dual output models, Output 1 is +Vo and Output 2 is +Vr. A 47 Mechanical Dimensions
µF/25V ceramic capacitor must be connected from +Vo (pin 12)
of dual output models to Common (pin 11). Without this capacitor,
the unit may not meet all specifications.
2. For dual output models, output voltage accuracy is specified as
±2% for +Vo and ±5% for +Vr.
3. For dual output models, line regulation is specified as ±0.2% for
+Vo and ±3% for +Vr.
4. For model MPM-04S-24, ripple is specified as 150 mV p-p and
noise is specified as 200 mV p-p.
5. Output short circuit protection is provided by a "hiccup mode"
circuit. The unit recovers automatically when the fault condition
is removed.
6. Operation at under no load conditions will not damage these units.
It is recommended that the minimum load values in the table above
be used.
7. It is recommended that a fuse be used on the input of a
power supply for protection. For the MPM-04 series, a
1A/250 VAC slow blow should be used.
Notes:
Derating Curve · All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
Pin Connections
Pin Single Dual
1 NC NC
7 AC-Neutral
9 AC-Line
10 NC +Vr
11 -Vo Common
12 +Vo +Vo
18 NC NC
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 · TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail: sales@micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de