MPM-08MB Series
Single & Dual Output, 8W
Miniature "Power Brick"
AC/DC Power Supplies
Key Features: Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
· 8W Output Power Input
· Miniature Case Parameter Conditions Min. Typ. Max. Units
· Wide 90-305 VAC Input 90 305 VAC
Input Voltage Range
· EN 60950 Approved (UL) 120 430 VDC
Input Frequency 47 440 Hz
· Meets IEC Safety Class II Input Current See Model Selection Guide
· Meets EN 55022 B Inrush Current
115 VAC 25.0
A Pk
· Eight Standard Models 230 VAC 45.0
Leakage Current 0.25 mA
· >350 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
EMC Meets EN 55024
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy See Note 1 ±2.0 %
Line Regulation, See Note 2 VIN = Min to Max ±0.2 %
Load Regulation, See Note 3 See Model Selection Guide
3.3, 5, 9 12, 15 Vout Models 100
Ripple (20 MHz), See Note 4 24 Vout Models 150 mV P - P
Dual Output Models 100
3.3, 5, 9 12, 15 Vout Models 150
Noise 24 Vout Models 200 mV P - P
Dual Output Models 150
115 VAC 10
Hold-Up Time mSec
230 VAC 75
Temperature Coefficient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, See Note 5 Continuous (Autorecovery)
Overload Protection 115 150 % of IO
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) EN 61000-4-2 Level B
RF Field Susceptibility EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV
Surge EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 132 kHz
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street 5.0/3.3 Vout Model -25 +25 +70
Operating Temperature Range, Ambient °C
Suite D All Other Models -40 +25 +70
Storage Temperature Range -40 +125 °C
Stoughton, MA 02072
Cooling Free Air Convection (See Derating Curves)
USA
Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226 Case Size 1.44 x 1.06 x 1.04 Inches (36.5 x 27.0 x 26.4 mm)
F: (781) 344-8481 Case Material Non-Conductive Plastic & Fiberglass (UL94-V0)
E: sales@micropowerdirect.com Weight 1.58 Oz (45g)
W: www.micropowerdirect.com Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 350 kHours
Vibration 10~55 Hz, 20G 1 min/1 Cycle. Period of 3 min each along X, Y &Z Axis
Safety Approvals UL, cUL; File No. E245422
Safety Class IEC 61140 Class II
www.micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output Load Maximum Maximum
Model Capacitive Output Efficiency
Current (A) Voltage Current Regulation
Number Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. (A) Min. (%) (% Max) (µF) (W)
MPM-08S-03MB 0.190 0.120 3.3 2.000 0.0 ±3.0 26,000 6.60 72
MPM-08S-05MB 0.190 0.120 5.0 1.600 0.0 ±2.0 6,000 8.00 78
MPM-08S-09MB 0.190 0.120 9.0 0.888 0.0 ±0.5 2,300 8.00 79
MPM-08S-12MB 0.190 0.120 12.0 0.666 0.0 ±0.5 1,050 8.00 79
MPM-08S-15MB 0.190 0.120 15.0 0.533 0.0 ±0.5 440 8.00 80
MPM-08S-24MB 0.190 0.120 24.0 0.335 0.0 ±0.5 180 8.00 81
5.0 1.600 25.0 ±0.5 4,500
MPM-08D-0503MB 0.200 0.125 9.00 76
3.3 0.310 25.0 ±5.0 3,800
12.0 0.666 25.0 ±0.5 260
MPM-08D-1205MB 0.200 0.125 8.50 79
5.0 0.100 25.0 ±5.0 3,800
Notes:
1. The output voltage accuracy of the V2 output (pin 5) on dual outputs is ±15% for the MPM-08D- Mechanical Dimensions
0503MB, and ±10% for the MPM-08D-1205MB.
2. The line regulation of the dual output models is ±2.0% for the V1 output (pin 4), and ±3% for
the V2 output (pin 5).
3. Load regulation is measured from 10% load to 100% load.
4. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor con-
nected in parallel as close to the unit output terminals as possible.
5. Output short circuit protection is provided by a "hiccup mode" circuit. The unit recovers automatically when
the fault condition is removed.
6. Operation under no load conditions will not damage single output units. For dual output units, minimum load
requirements are given in the table above.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the
MPM-08MB series, a 2A/250 VAC slow blow should be used.
Derating Curve - Single Output Models
Derating Curve - Dual Output Models
Notes:
· All dimensions are typical in inches (mm)
Pin Connections
· Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual
1 AC-Line
2 AC-Neutral
3 NC Common
4 +Vout Vout1
5 -Vout Vout2
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 ·
CompuMess ElektronikFAX: (781) 344-8481 · E-Mail:·sales@micropowerdirect.com
TEL: (781) 344-8226 · GmbH · Lise-Meitner-Str. 4 D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de