Hier Klicken für das PDF Dokument!!!

MPM-25S Series
Universal Input, 25W
Miniature, PC Mount
AC/DC Power Supplies
                                Electrical Specifications
                                Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:                    Input
· 25W Output Power               Parameter                                                              Conditions                  Min.   Typ.                   Max.          Units
· Universal 85-264 VAC Input                                                                                                         85                           264           VAC
                                 Input Voltage Range
                                                                                                                                    120                           370           VDC
· EN 60950 Approved              Input Frequency                                                                                     47                            63            Hz
· Adjustable Output              Input Current                                                                       See Model Selection Guide
· Meets EN55022 B                                                                                                        115 VAC           16.0
                                 Inrush Current                                                                                                                                  A Pk
                                                                                                                         230 VAC           30.0
· >200 kHour MTBF
                                 EMI                                                                              Meets CISPR Pub. 22/FCC Class B
· Compact PC Mount Case                                                                                                  115 VAC                                    0.1
                                 Safety Ground Leakage Current                                                                                                                    mA
                                                                                                                         230 VAC                                    0.3
                                 Output
                                Parameter                                                               Conditions              Min.    Typ.                      Max.          Units
                                Output Voltage                                                                    See Model Selection Guide
                                Output Current                                                                    See Model Selection Guide
                                Output Voltage Accuracy                                                                                 ±2.0                                       %
                                Line Regulation                                                                                         ±0.5
                                Load Regulation                                                                   See Model Selection Guide
                                Ripple & Noise (20 MHz)                                                                                  50                                  mV Pk - Pk
                                                                                                                      115 VAC            20
                                Hold-Up Time                                                                                                                                    mSec
                                                                                                                      230 VAC            80
                                Temperature Coefficient                                                                                ±0.02                                     %/°C
                                Short Circuit Protection                                                          Continuous (Autorecovery)
                                Overload Protection                                                              Typ. 110% of Output Power
                                 General
                                 Parameter                                                             Conditions                           Min.        Typ.      Max.          Units
                                                                                                                  Input to Output           3,000
                                 Isolation Voltage                                                               Input to Ground            1,500                                VAC
                                                                                                              Output to Ground               500
                                 EMI/RFI                                                                              Conducted                      EN 55022 Level B
                                                                                                Electrostatic Discharge (ESD)                    IEC/EN 61000-4-2 Level 3
                                                                                                         RF Field Susceptibility                     IEC/EN61000-4-3
                                 EMC Compliance
                                                                                       Electrical Fast Transients/Bursts On Mains             IEC/EN 61000-4-4 Level 3 2 kV
                                                                                                                            Surge           IEC/EN 61000-4-5 Level 3 1kV/2 kV
                                 Switching Frequency                                                                                                  150             kHz
                                 Environmental
                                 Parameter                                                              Conditions                          Min.   Max. Typ.                    Units
MicroPower Direct                Operating Temperature Range
                                                                                                                             Ambient        -25    +70  +25                      °C
292 Page Street                                                                                                                Case                +90                           °C
Suite D                          Storage Temperature Range                                                                          -25            +105                          °C
Stoughton, MA 02072              Cooling                                                                     Free Air Convection (See Derating Curve)
USA                              Humidity                                                                   RH, Non-condensing                      85                             %
                                 Physical
T: (781) 344-8226                Case Size                                                                                2.75 x 1.88 x 0.92 Inches (70.0 x 48.0 x 23.5 mm)
F: (781) 344-8481
                                 Case Material                                                                                     Non-Conductive Black Plastic (UL94-V0)
E: sales@micropowerdirect.com
                                 Weight                                                                                                                      5.65 Oz (160g)
W: www.micropowerdirect.com
                                 Reliability Specifications
                                 Parameter                                                        Conditions                Min.   Typ.                           Max.          Units
                                 MTBF                                                    MIL HDBK 217F, 25°C, Gnd Benign    200                                                kHours
                                 Safety Standards                                                              IEN 60950, IEC 60950
                                 Safety Approvals                                                              IEN 60950, IEC 60950

                                                                  www.micropowerdirect.com
                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                            info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                                                 CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                                 Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                                                               www.micropowerdirect.com
                                                                                                                 info@compumess.de · www.compumess.de · www.netzteile.de

                                       Input                                          Output 1 (Vout 1)
       Model                         Current (A)                                         Current (A)          Over Volt.           Efficiency
      Number                                                        Voltage                                                            (%, Typ)
                                                                      (VDC)
                                                                                                 Load         Protection
                             115 VAC            230 VAC                               Typ.                         (VDC)
                                                                                                 Reg.
MPM-25S-05                      0.42               0.23               5.0             4.10      ±1.0%             6.5                     74
MPM-25S-12                      0.42               0.23               12.0            2.10      ±1.0%             20.0                    82
MPM-25S-15                      0.42               0.23               15.0            1.60      ±1.0%             20.0                    83
MPM-25S-24                      0.42               0.23               24.0            1.10      ±1.0%             30.0                    85
MPM-25S-48                      0.42               0.23               48.0            0.50      ±1.0%             60.0                    87
Notes:
1. Load regulation is measured for an output change of 10% to 90% at                                 Derating Curve
   nominal input line. For multiple output models, the loads are balanced.
2. As shown in the connection diagram at right, a simple external circuit may
   be used to adjust the power supply output ±10%. To adjust the output DOWN,
   connect a 5%, 3W resistor between the plus output pin and the Vout trim pin.
   To adjust the output UP, connect a 5%, 3W resistor between the minus output
   pin and the Vout trim. Contact the factory for resistor values needed to achieve
   a specific output.
3. It is recommended that a fuse be used on the input of a power supply for
   protection. For the MPM-25 series, a 3.15A/250 VAC slow blow should
   be used.


Mechanical Dimensions




                                                                                                          Typical Connection




                                                                                                          Typical Component Values
                                                                                                            Vout                 C1                           C2                  Fuse                 TVS
                                                                                                             5.0             330 µF/16V                                                              P6KE6.8A
                                                                                                            12.0             330 µF/25V                                                              P6KE16A
                                                                                                                                                                                 3.15A/
                                                                                                            15.0             330 µF/25V                0.01 µF/25V                                   P6KE20A
                                            Notes:                                                                                                                              250 VAC
                                            · All dimensions are typical in inches (mm)                     24.0             120 µF/35V                                                              P6KE33A
                                            · Tolerance x.xx = ±0.01 (±0.25)                                48.0              68 µF/35V                                                              P6KE33A
        Pin
    Connections                                                                                           Notes:
      Pin        Function                                                                                 1. C1 is a high frequency, low resistance electrolytic capacitor. Refer to the suppliers specifications
                                                                                                             for capacitance/current ratings.
        1       AC-Ground                                                                                 2. Voltage derating on all capacitors should be 80% or higher.
        2       AC-Neutral                                                                                3. C2 eliminates high frequency noise.
        3        AC-Line                                                                                  4. The power supply includes an internal TVS. If the user requires a tighter OVP threshold, an external
                                                                                                             TVS may be connected as shown.
        4         -Vout
        8         +Vout
      Trim         Trim




                                     MicroPower Direct
                                     We Power Your Success - For Less!
                                    292 Page Street Ste D Stoughton, MA 02072                    ·   TEL: (781) 344-8226           ·    FAX: (781) 344-8481           ·   E-Mail: sales@micropowerdirect.com
                                                                                                     CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                     Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                                     info@compumess.de · www.compumess.de · www.netzteile.de