Hier Klicken für das PDF Dokument!!!

MPO-200S Series
Single Output, 200W
Miniature, Open Frame
AC/DC Power Supplies
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:                    Input
· 200W Output Power              Parameter                                                              Conditions                Min.    Typ.   Max.                            Units
· PFC to EN 61000-3-2,3 "D"                                                                                                 Universal
                                                                                                                                    90            264                            VAC
                                 Input Voltage Range
                                                                                                                                   127            373                            VDC
· Universal 90-264 AC Input
                                 Input Frequency                                                                                    47             63                             Hz
· EN 60950 Approved (UL)         Input Filter                                                                  Meets EN 55022 Class B; FCC Class B
· Miniature 3 x 5 In Package     Input Current                                                                      See Model Selection Guide
· Meets EN 55022 B                                                                                            Cold Start, 115 VAC                 36.0
                                 Inrush Current                                                                                                                                  A Pk
· Efficiency To 92%                                                                                           Cold Start, 230 VAC                100.0
                                 Safety Ground Leakage Current                                                            264 VAC                 3.5                             mA
· >110 kHour MTBF
                                 Output
                                Parameter                                                               Conditions               Min.    Typ.                     Max.           Units
                                Output Voltage/Current                                                             See Model Selection Guide
                                Output Voltage Tolerance                                                             See Note 1          ±1.0                                     %
                                Line Regulation                                                               Vin = Min to Max           ±0.5                                     %
                                Load Regulation                                                            Iout = 10% to 100%            ±1.0                                     %
                                Ripple & Noise (20 MHz)                                                              See Note 2          ±1.0                                     %
                                Hold-Up Time                                                                         See Note 3           10                                     mSec
                                Temperature Coefficient                                                                                 ±0.05                                    %/°C
                                Short Circuit Protection                                                           Continuous (Autorecovery)
                                Over Voltage Protection                                                              See Note 3           130                                      %
                                 General
                                 Parameter                                                              Conditions                          Min.        Typ.      Max.  Units
                                 Isolation Voltage                                                              Input to Output             4,000                       VAC
                                 Isolation Resistance                                                                  500 VDC                        1,000              M
                                 Isolation Capacitance                                                                                                5,845               pF
                                 EMI/RFI                                                                              Conducted                      EN 55022; EN 61000-3-2, -3
                                                                                                Electrostatic Discharge (ESD)                       IEC/EN 61000-4-2, -6, -8, -11
                                                                                                         RF Field Susceptibility                              IEC/EN 61000-4-3
                                 EMC Compliance
                                                                                       Electrical Fast Transients/Bursts On Mains                             IEC/EN 61000-4-4
                                                                                                                           Surge                              IEC/EN 61000-4-5
                                 Switching Frequency                                                                        Fixed                       90               kHz
                                 Environmental
                                 Parameter                                                              Conditions               Min.    Typ.                     Max.           Units
MicroPower Direct                Operating Temperature Range                                                                      -20
                                                                                                                              Ambient    +25                      +80             °C
292 Page Street
                                 Storage Temperature Range                                                                        -20                             +85             °C
Suite D
Stoughton, MA 02072              Cooling                                                                              See Derating Curve
USA                              Humidity                                                                   RH, Non-condensing                                      93             %
                                 Physical
T: (781) 344-8226                Size                                                                              5.00 x 3.00 x 1.44 Inches (127.00 x 76.20 x 34.00 mm)
F: (781) 344-8481
                                 Weight                                                                                                               14.10 Oz (0.400 kg)
E: sales@micropowerdirect.com
W: www.micropowerdirect.com      Reliability Specifications
                                 Parameter                                                          Conditions                Min.    Typ.    Max.       Units
                                 MTBF                                                   MIL HDBK 217F, 25°C, Gnd Benign        110                      kHours
                                 Safety Standards                                                                 UL 60950, EN 60950
                                 Vibration                                              Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis

                                                                  www.micropowerdirect.com
                                                         CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
                                                         Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                         info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                                  CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
                                                                                                  Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                                             www.micropowerdirect.com
                                                                                                  info@compumess.de · www.compumess.de · www.netzteile.de

                                  Input                                 Output                                    Output Power                  Max
      Model                     Current (A)                                Current (A)                                (Max. W)                 Output               Efficiency
     Number                                              Voltage                                                                             Capacitance             (%, Typ)
                                                          (VDC)    Maximum Maximum
                          115 VAC        230 VAC                                                  % Min. With 19 CFM Convection                     (µF)
                                                                   (With 19 CFM)   (Convection)
MPO-200S-12                   3.0            1.5           12.0        16.67            12.50       0.00        200           150                   6,000                89
MPO-200S-24                   3.0            1.5           24.0         8.34             6.25       0.00        200           150                   6,000                90
MPO-200S-36                   3.0            1.5           36.0         5.56             4.17       0.00        200           150                   4,450                91
MPO-200S-48                   3.0            1.5           48.0         4.17             3.13       0.00        200           150                   3,700                92
Notes:
1. Output voltage tolerance is measured at nominal
                                                        Derating Curve
   input and 60% load.
2. Output ripple is measured at 20 MHz bandwidth
   using 0.1 µF and 10 µF capacitors connected in
   parallel as close to the power supply terminals as
   possible.
3. Hold-up time is typical for 115 VAC and 230 VAC                                                                           Connections
   inputs.                                                                                                                   Input Connector (CN1):
4. These units will operate at no load without                                                                               · TKP PVH1-3N2 or equivalent (one pin removed)
   damage. For most applications however, MPD                                                                                · Mating Housing: JST VHR-3N or equivalent
   recommends that a minimum load always be                                                                                  · Mating Terminal: SVH-21T-PH1 or equivalent
   used. Contact the factory for more information.
5. The remote sense outputs may be used to com-                                                                                                Pin       Function
   pensates for up to a 0.5V line drop.                                                                                                         1        AC-Line
6. The fan drive provides 12VDC @ 300 mA.                                                                                                       2        Removed
7. Each unit includes an input fuse (250V/5A). Since
                                                                                                                                                3       AC-Neutral
   this fuse is not field replaceable, it is recom-
   mended that an external fuse of the same size                                                                             Safety Ground:
   be used on the input of the power supply for                                                                              The unit should be mounted using metal standoffs. The
   protection.                                                                                                               input side mounting hole marked "FG" provides the safety
                                                                                                                             earth ground for the unit. This point should be connected to
                                                                                                                             the system earth ground via a metal spacer or a cable. This
                                                                                                                             connection should be locked to prevent possible loosening.
Mechanical Dimensions                                                                                                        Connecting the output side mounting holes to earth ground
                                                                                                                             improves EMI (this connection will also put the rear heatsink
                                                                                                                             at ground potential).
                                                                                                                             Output Connector (CN2):
                                                                                                                             · TKP PVH1-08 or equivalent
                                                                                                                             · Mating Housing: JST-VHR-8N or equivalent
                                                                                                                             · Mating Terminal: SVH-21T-PH1 or equivalent

                                                                                                                                 Pin      Function            Pin        Function
                                                                                                                                  1        +VOUT               5           -VOUT
                                                                                                                                  2        +VOUT               6           -VOUT
                                                                                                                                  3        +VOUT               7           -VOUT
                                                                                                                                  4        +VOUT               8           -VOUT
                                                                                                                             Remote Sense Connector (CN3):
                                                                                                                             · LCU P205DG-02 or equivalent
                                                                                                                             · Mating Housing: Molex 5051-02 or equivalent
                                                                                                                             · Mating Terminal: Molex 5159 or equivalent

                                                                                                                                               Pin         Function
                                                                                                                                                1            +Rs
                                                                                                                                                2            -Rs
                                                                                                                             Fan Drive Connector (CN4):
                                                                                                                             · LCU P205DG-02 or equivalent
                                                                                                                             · Mating Housing: Molex 5051-02 or equivalent
                                                                                                                             · Mating Terminal: Molex 5159 or equivalent

                                                                                                                                          Pin   Function
                                                                                                                                           1    +Fan Out
                                                                                                                                           2    -Fan Out
                                                                                                                               See note 5 above




                                MicroPower Direct                                                                          Notes:
                                                                                                                           · All dimensions are typical in inches (mm)
                                                                                                                           · Tolerance x.xx = ±0.02 (±0.50)
                                We Power Your Success - For Less!
                               292 Page Street Ste D Stoughton, MA 02072           ·   CompuMess ElektronikFAX: (781) 344-8481 · E-Mail:· D-85716 Unterschleißheim
                                                                                        TEL: (781) 344-8226 ·    GmbH · Lise-Meitner-Str. 4 sales@micropowerdirect.com
                                                                                       Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                       info@compumess.de · www.compumess.de · www.netzteile.de