MPO-65S Series
Si l O
Single Output, 65W
6
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
· 65W Output Power Parameter Conditions Min. Typ. Max. Units
· Universal 90-264 AC Input Universal90 264 VAC
Input Voltage Range
127 370 VDC
· EN 60950 Compliant
Input Frequency 47 63 Hz
· Low Leakage Current Input Current See Model Selection Guide
· Nine Single Output Models Cold Start, 115 VAC 20.0
Inrush Current A Pk
Cold Start, 230 VAC 40.0
· Meets EN55022
115 VAC 0.35
· >300 kHour MTBF Safety Ground Leakage Current mA
240 VAC 0.5
· Only 5" x 3" x 1.6" Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Adjustment See Model Selection Guide
Output Voltage Tolerance, See Note 1 See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide
115 VAC 15
Hold-Up Time mSec
230 VAC 60
Set-Up Time 230 VAC 800 mSec
Rise Time 230 VAC 20 mSec
RoHS Compliant Temperature Coefficient ±0.02 %/°C
Short Circuit Protection Continuous (Autorecovery)
Over Voltage Protection See Note 3 115 135 %
Overload Protection See Note 4 112 160 %
General
Parameter Conditions Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage Input to Ground 1,500 VAC
Output to Ground 500
Isolation resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022; EN 61000-3-2, -3
Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11
MicroPower Direct RF Field Susceptibility IEC/EN61000-4-3
292 Page Street EMC Compliance
Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4
Suite D Surge IEC/EN 61000-4-5
Stoughton, MA 02072
Switching Frequency Fixed 65 kHz
USA
Environmental
T: (781) 344-8226 Parameter Conditions Min. Typ. Max. Units
F: (781) 344-8481 Operating Temperature Range Ambient
-10 +25 +60 °C
E: sales@micropowerdirect.com Storage Temperature Range -20 +85 °C
W: www.micropowerdirect.com Cooling Free Air Convection (See Derating Curve)
Humidity RH, Non-condensing 95 %
Physical
Size 5.00 x 3.00 x 1.65 Inches (127.0 x 76.2 x 42.0 mm)
Weight 7.4 Oz (0.21 kg)
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 300 kHours
Safety Standards IEN 60950, IEC 60950
Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output
Output Ripple &
Model Current (A) Voltage (VDC) Current (A) Efficiency
Tolerance Noise
Number (%, Typ)
115 VAC 230 VAC Rated Adjust Rated Range (%) (mV p-p)
MPO-65S-3.3 1.20 0.72 3.3 3.14 - 3.63 12.0 0 to 15.2 ±3.0 80 69
MPO-65S-05 1.20 0.72 5.0 4.75 - 5.5 12.0 0 to 13.8 ±3.0 100 76
MPO-65S-7.5 1.20 0.72 7.5 7.13 - 8.25 8.0 0 to 9.6 ±3.0 100 79
MPO-65S-12 1.20 0.72 12.0 11.4 - 13.2 5.2 0 to 6.0 ±2.0 100 79
MPO-65S-13.5 1.20 0.72 13.5 12.8 - 14.9 4.7 0 to 5.4 ±2.0 100 79
MPO-65S-15 1.20 0.72 15.0 14.25 - 16.5 4.2 0 to 4.8 ±2.0 100 79
MPO-65S-24 1.20 0.72 24.0 22.8 - 26.4 2.7 0 to 3.0 ±2.0 100 80
MPO-65S-27 1.20 0.72 27.0 25.65 - 29.7 2.4 0 to 2.7 ±2.0 100 80
MPO-65S-48 1.20 0.72 48.0 45.6 - 52.8 1.3 0 to 1.5 ±2.0 100 80
Notes:
1. Output voltage tolerance includes the the effects of set point Mechanical Dimensions
accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth using
a 12 inch twisted pair wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in
parallel as close to the power supply terminals as possible.
3. Overvoltage protection is provided by a "hiccup mode" circuit.
The unit recovers automatically when the fault condition is
removed.
4. Overload protection is provided by a "hiccup mode" circuit.
The unit recovers automatically when the fault condition is
removed. For the 3.3V output model, overload protection is
set to operate between 36 to 55W.
5. Mounting holes M1 and M2 should be grounded for EMI
purposes.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the mechanical diagram for the
correct rating.
Pin Connections: CN1 (Molex 5277-02 or equiv.)
Mating
Pin Function Terminal
Housing
1 AC-Neutral Molex 5195 Molex 5194
2 AC-Line or Equiv. or Equiv.
Pin Connections: CN2 (Molex 5273-06 or equiv.)
Mating
Pin Function Terminal
Housing
1, 2, 3 +Vout Molex 5195 Molex 5194
4, 5, 6 -Vout or Equiv. or Equiv.
Notes:
Output Derating vs Input Voltage Derating Curve · All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 · Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 sales@micropowerdirect.com
TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail: