MPS-03 Series
Single Output, 3W
Ultra-Miniature SIP
AC/DC Power Supplies
                                Electrical Specifications
                                Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:                    Input
· 3W Output Power                Parameter                                                              Conditions                          Min.        Typ.      Max.          Units
· Universal 85-264 VAC Input                                                                                              See Note 1          85                   264           VAC
                                 Input Voltage Range
· 100 - 400 VDC Input                                                                                                                        100                   400           VDC
· Meets IEC Safety Class II      Input Frequency                                                                                              47                    63            Hz

· -40ºC to +85ºC Operation       Input Current                                                                         See Model Selection Guide
                                                                                                                             115 VAC                     10
· Single Regulated Output        Inrush Current, See Note 1                                                                                                                        A
                                                                                                                             230 VAC                     20
· >200 kHour MTBF
                                 Leakage Current                                                                                                                    50             µA
· Ultra-Miniature SIP Case
                                 Output
                                Parameter                                                               Conditions                          Min.        Typ.      Max.          Units
                                Output Voltage                                                                         See Model Selection Guide
                                Output Current                                                                         See Model Selection Guide
                                Output Voltage Accuracy                                                                                                 ±2.0                       %
                                Line Regulation                                                                VIN = 10% to 100%                        ±0.5                       %
                                Load Regulation                                                                           See Note 2                    ±1.0                       %
                                                                                                   3.3V And 5V Output Models                             50
                                Ripple & Noise (20 MHz)                                                                                                                      mV Pk - Pk
                                                                                                                   All Other Models                     100
                                                                                                                             115 VAC          16
                                 Hold Time, See Note 1                                                                                                                            mS
                                                                                                                             230 VAC          40
                                Temperature Coefficient                                                                                                ±0.02                     %/°C
                                Short Circuit Protection                                                                Continuous (Autorecovery)
                                Over Temperature Protection                                                               See Note 3                               150             °C
                                 General
                                 Parameter                                                              Conditions                          Min.        Typ.      Max.          Units
                                 Isolation Voltage                                                                  Input to Output         2,000                                VAC
                                 Switching Frequency                                                                                                    100                       kHz
                                 Environmental
                                 Parameter                                                              Conditions                          Min.        Typ.      Max.          Units
                                 Operating Temperature Range                                                                 Ambient         -40        +25        +85             °C
                                 Operating Temperature Range                                                                      Case                             +90             °C
MicroPower Direct                Storage Temperature Range                                                                                   -40                  +105             °C
292 Page Street
                                 Cooling                                                                      Free Air Convection (See Derating Curve)
Suite D
Stoughton, MA 02072              Humidity                                                                   RH, Non-condensing                                      85             %
USA                              Physical
                                 Case Size                                                                                1.34 x 0.42 x 0.87 Inches (34.0 x 10.6 x 22.5 mm)
T: (781) 344-8226
F: (781) 344-8481                Case Material                                                                                                Non-Conductive Epoxy (UL94-V0)
E: sales@micropowerdirect.com    Weight                                                                                                                                   1.24 Oz (35g)
W: www.micropowerdirect.com
                                 Reliability Specifications
                                 Parameter                                                              Conditions                          Min.        Typ.      Max.          Units
                                 MTBF                                                    MIL HDBK 217F, 25°C, Gnd Benign                     200                               kHours
                                 Safety Class                                                                                IEC 61140 Class II


                                                                  www.micropowerdirect.com
                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                            info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                                      CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                      Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                                                 www.micropowerdirect.com
                                                                                                      info@compumess.de · www.compumess.de · www.netzteile.de

                        Input                  Output                               Typical Connection
     Model                                                          Efficiency
    Number            Current         Voltage        Current          (%, Typ)
                         (mA)           (VDC)           (mA)

MPS-03S-03                40             3.3            500               63
MPS-03S-05                40             5.0            500               72
MPS-03S-09                40             9.0            330               74
MPS-03S-12                40            12.0            250               76
MPS-03S-15                40            15.0            200               76
MPS-03S-24                40            24.0            125               78
Notes:
1. Specified with a C4 (see typical connection diagram at right) value of
   22 uF/400V. A high frequency, low impedance electrolytic capacitor should
   be used.
2. Load regulation is measured for an output change of 10% to 90% at nominal
   input line. For multiple output models, the loads are balanced.
3. The unit will shut down when the over temperature protection is triggered. The
   unit will restart when the ambient operating temperature falls below 85ºC.
4. It is recommended that a fuse be used on the input of a power supply for
   protection. For the MPS-03 series, a 0.5A/250 VAC slow blow should be
   used.


                                                                                                           The diagram above illustrates a typical application connection of the MPS-03 series. The
Derating Curve                                                                                             top diagram illustrates a DC/DC converter connection while the bottom diagram show the
                                                                                                           unit connected as an AC/DC power supply. Notes on these circuits are:
                                                                                                           1. To maintain clearance and creepage distances (for Class I & Class II devices) the board
                                                                                                              layout should guarantee the following spacing between the L and N inputs (before the
                                                                                                              fuse):
                                                                                                                                        Clearance - 2 mm
                                                                                                                                        Creepage - 2.5 mm
                                                                                                           2. The recommended fuse is a 0.5A/250V slow blow.
                                                                                                           3. For EMI sensitive applications, the input filtering circuit (inside the dotted boxes of the
                                                                                                              AC circuit) may be added. The filter consists of:
                                                                                                                     Cx: Capacitor C1 is 0.1 µF/275V
                                                                                                                     CY: Capacitors C2 and C3 are 220 pF/2000V
                                                                                                                     T1: Common mode choke, UU9.8 or ring core. Inductance is
                                                                                                                         about 10 mH to 30 mH & wire diameter of 0.22 mm.
                                                                                                           4. The MOV is required for surge protection.                      C5        C6
                                                                                                              Recommended is a 471KD07.                           VOUT                          TVS
                                                                                                                                                                           (µF/V)    (µF/V)
                                                                                                           5. The input storage capacitor (C4) is a low ESR        3.3     150/25    0.1/50   P4KE6.8A
                                                                                                              electrolytic with a rating of 22 µF /400V. This      5.0     150/25    0.1/50   P4KE6.8A
                                                                                                              capacitor must be used for operation with an         9.0     150/25    0.1/50   P4KE12A
                                                                                                              AC input.
                                                                                                                                                                  12.0     150/25    0.1/50   P4KE20A
                                                                                                           6. The output filtering capacitor (C5) is a high
Mechanical Dimensions                                                                                         frequency, low resistance electrolytic capacitor.   15.0     100/35    0.1/50   P4KE20A
                                                                                                              A ceramic capacitor (C6) is used to filter high     24.0     100/35    0.1/50   P4KE33A
                                                                                                              frequency noise. Recommended values are
                                                                                                              given in the table at right.
                                                                                                           7. The TVS is recommended to protect application circuitry in the event of a fault. Recom-
                                                                                                              mended values are given in the table above.



                                                                                                                           Pin Connections
                                                                                                                            Pin            Function
                                                                                                                               1      +Vin (AC-Line)
                                                                                                                               3            CAP
                                                                                                                               6     -Vin (AC-Neutral)
                                                                                                                              10           -Vout
                                                                                                                              12           +Vout


                                                                                                                  Notes:
                                                                                                                  · All dimensions are typical in inches (mm)
                                                                                                                  · Tolerance x.xx = ±0.01 (±0.25)




                                  MicroPower Direct
                                  We Power Your Success - For Less!
                                 292 Page Street Ste D Stoughton, MA 02072              ·   TEL: (781) 344-8226
                                                                                            CompuMess Elektronik GmbH 344-8481 · E-Mail: sales@micropowerdirect.com
                                                                                                                · FAX: (781)
                                                                                                                              · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                            info@compumess.de · www.compumess.de · www.netzteile.de