MPU-360F Series
Compact U-Channel, 360W
Power Factor Corrected,
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
· 360W Output Power Parameter Conditions Min. Typ. Max. Units
Universal
90 264 VAC
· Universal 90-264 AC Input Input Voltage Range
120 370 VDC
· Built-In DC Fan (End) Input Frequency 47 63 Hz
· Active PFC = >0.99 Input Filter Meets EN 55022 Class B; FCC Class B
Input Current See Model Selection Guide
· EN 60950 Approved Cold Start, 115 VAC 30.0
Inrush Current, <2 mS A Pk
· Low Leakage Current Cold Start, 230 VAC 60.0
· Four Single Output Models Safety Ground Leakage Current 264 VAC, 63 Hz 0.3 mA
115 VAC 0.99
· Meets EN 55022 B Power Factor Correction, See Note 1 W/VA
230 VAC 0.93
· >120 kHour MTBF Output
Parameter Conditions Min. Typ. Max. Units
· Only 7.8" x 3.2" x 1.57" Output Voltage/Current See Model Selection Guide
Minimum Load 0.0 %
Output Voltage Tolerance ±2.0 %
Line Regulation Vin = Min to Max ±1.0 %
Load Regulation Iout = 5% to 100% ±1.0 %
12 VDC Output 150
Ripple & Noise (20 MHz), See Note 2 mV P - P
24, 36, 48 VDC Output 200
Hold-Up Time 115 VAC 12 mSec
Temperature Coefficient ±0.03 %/°C
Short Circuit Protection Continuous (Autorecovery)
Over Voltage Protection See Model Selection Guide
Overload Protection See Note 3 130 150 %
General
Parameter Conditions Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage Input to Ground 1,500 VAC
Output to Ground 500
Isolation resistance 500 VDC 100 M
Isolation Capacitance 4,700 pF
EMI/RFI Conducted EN 55022; EN 61000-3-2, -3
Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11
RF Field Susceptibility IEC/EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4
Surge IEC/EN 61000-4-5
Switching Frequency Fixed 75 kHz
MicroPower Direct Environmental
292 Page Street
Parameter Conditions Min. Typ. Max. Units
Suite D
Operating Temperature Range Ambient
-10 +25 +70 °C
Stoughton, MA 02072
USA Storage Temperature Range -25 +85 °C
Cooling Free Air Convection (See Derating Curve)
T: (781) 344-8226 Humidity RH, Non-condensing 95 %
F: (781) 344-8481 Physical
E: sales@micropowerdirect.com Size 7.78 x 3.2 x 1.57 Inches (197.7 x 81.3 x 40.0 mm)
W: www.micropowerdirect.com Weight 26.3 Oz (0.746 kg)
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 50 kHours
Safety Standards UL 1950, EN 60950, IEC 60950
Vibration 10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output Maximum Over Max.
Model Minimum Output Voltage Capacitive Efficiency
Current (A) Voltage Current
Number Load Power Protection Load (%, Typ)
115 VAC 230 VAC (VDC) (A) (W) (VDC) (µF)
(%)
MPU-360S-12T(A)F 4.0 2.0 12.0 30.0 0.0 360 15.0 85,000 90
MPU-360S-24T(A)F 4.0 2.0 24.0 15.0 0.0 360 28.0 48,000 92
MPU-360S-36T(A)F 4.0 2.0 36.0 10.0 0.0 360 40.0 21,000 93
MPU-360S-48T(A)F 4.0 2.0 48.0 7.50 0.0 360 57.0 13,000 93
For a 360W unit with a cover and top fan, see the MPU-360E datasheet; For a unit without a cover or fan, see the MPU-360 datasheet
Notes:
1. PFC meets EN61000-3-2. Model Number Derating Curve
2. Ripple and noise is measured at 20 MHz
bandwidth using a 0.1 µF and a 47 µF
capacitor connected in parallel as close to
the power supply terminals as possible.
3. Overload protection is provided by a "hiccup
mode" circuit. The unit recovers automati-
cally when the fault condition is removed.
4. These units will operate at no load without
damage.
5. Each unit includes an input fuse. Since this
fuse is not field replaceable, it is recom-
mended that an external fuse be used on
the input of the power supply for protection.
For these units, a 15A/250V slow blow fuse
is recommended.
Mechanical Dimensions
Pin Connections
Pin Function Pin Function
1 AC-Ground 4 +VOUT
2 AC-Neutral 5 +VOUT
3 AC-Line 6 +VOUT
7 -VOUT
8 -VOUT
9 -VOUT
Molex Connectors (Opt)
MicroPower Direct Notes:
· All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 ·
CompuMess ElektronikFAX: (781) 344-8481 · E-Mail:· D-85716 Unterschleißheim
TEL: (781) 344-8226 · GmbH · Lise-Meitner-Str. 4 sales@micropowerdirect.com
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de