Hier Klicken für das PDF Dokument!!!

MPU-800U Series
Single Output 800W
Power Factor Corrected
AC/DC Power Supplies
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:                    Input
· Compact 800W Supply            Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
· PFC to EN61000-3-2 "D"         Input Voltage Range                                                                         Universal        90                   264           VAC
                                 Input Frequency                                                                                              47                    63            Hz
· EN 60950 Approved (UL)         Input Current, Full Load                                                         90 VAC              5                                           A
· CE Certified                   Inrush Current, Cold Start
                                                                                                                 110 VAC                    35
                                                                                                                                                       A
                                                                                                                 220 VAC                    70
· FCC Class B Emissions
                                 Leakage Current                                                                 240 VAC             3.5              mA
· 12 - 60 V Output Voltages      Power Factor Correction                                                     Meets EN61000-3-2 Class D
· Universal AC Input             Input Protection                                                                 T12A/250V Fuse
                                 Input Undervoltage Protection                              Under 80VAC ±5 VAC Unit Shuts Down; Unit Recovers Over 86 VAC
· Current Share Option           Output
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                 Output Voltage Adjustment                                                                By Trim Pot                   ±5.0                      %
                                 Output Regulation, See Note 1                                                                                          ±1.0                      %
                                 Hold Time                                                               120 VAC, 80% Load        20                                             mSec
                                 Ripple & Noise (20 MHz), See Note 2                                              See Model Selection Guide
                                 Overload Protection                                            Foldback Circuit, Autorecovery   110          140                                  %
                                 Over Voltage Protection                                             >130% of Rated Output Voltage. Recycle AC Input.
                                 Over Temperature Protection                                                      Autorecovery           +85                                      ºC
                                 Temperature Coefficient                                                                               ±0.04                                     %/ºC
                                 Transient Recovery Time, See Note 4                                                                     2.5                                     mS
                                                                                                           50% Load Change
                                 Transient Response Deviation                                                                             5                                       %
                                 Overshoot/Undershoot                                                           At Turn On/Off                ±5.0                                %
                                 Turn On Delay                                                                        120 VAC                  1.5                                 S
                                 Output Short Circuit                                                           Continuous With Autorecovery
                                 General
                                 Parameter                                                              Conditions                          Min.        Typ.       Max.          Units
                                                                                                                   Input - Output           3,000
                                 Isolation Voltage, See Note 5                                        Input - FG (Frame Ground)             1,500                                 VAC
                                                                                                                  Primary - Core            1,500
                                 Switching Frequency                                                                        Fixed                        24                       kHz
                                 Interface Signals
                                 LED Power Supply On                                        Bi-color LED Is Green For Power On; Orange When Protection Enabled
                                                                                               An open collector output rated for 28V/5 mA sink current maximum.
                                 Fan Fail
                                                                                                                              Goes high if a fan failure is detected
                                 Current Monitor                                                A 0.5 to 3.0V Output That Represents 0% to 100% Output Current
                                 Current Share                                              Optional For Sharing Up To Four Units. Contact The Factory For Details
                                 Remote Sense                                                                            Compensates For Up To A 0.5V Line Drop
                                                                                             Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
                                 Power Good Signal
MicroPower Direct                                                                                                  before the loss of regulation. Will sink 100 mA.
                                 Remote On/Off                                                                  A TTL low signal inhibits the output. Hiccup mode.
292 Page Street
                                 Environmental
Suite D
                                 Parameter                                                               Conditions               Min.    Typ.    Max.      Units
Stoughton, MA 02072              Operating Temperature Range                                                                        0
                                                                                                                              Ambient      +25    +70         ºC
USA                              Output Derating                                                                                     2.5%/ ºC from +50 ºC to + 70 ºC
                                 Storage Temperature Range                                                                         -20            +85         ºC
T: (781) 344-8226                Cooling                                                                            See Model Selection Guide
F: (781) 344-8481                Operating Humidity                                                          RH, Non-condensing                    90         %
E: sales@micropowerdirect.com    Reliability Specifications
W: www.micropowerdirect.com      Parameter                                                        Conditions                 Min.    Typ.    Max.   Units
                                 MTBF                                                    MIL HDBK 217F, 30ºC, Gnd Benign     150                   kHours
                                 Safety Standards                                                               UL 60950, EN 60950
                                 EEMI Compliance                                              Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
                                 EMS Immunity Compliance                                        EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
                                 Vibration                                                         5~50 Hz, Acceleration 7.35 ms3 on X, Y & Z Axis

                                                                   www.micropowerdirect.com
                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                            info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                   CompuMess Elektronik GmbH · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
                                                                                   Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                          www.micropowerdirect.com
                                                                                   info@compumess.de · www.compumess.de · www.netzteile.de

                                                                                            Notes:
                Output Voltage (VDC)    Output        Max.                                  1. Output regulation includes line & load.
                                                               Ripple
    Model                               Current      Output    & Noise Efficiency           2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit
   Number       PreSet     Range       With 30 CFM   Power                 (%)                 is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor
                                                                (% p-p)
                                         (Max A)      (W)                                      connected in parallel.
                                                                                            3. A 1% minimum load is required to maintain regulation & ripple specifica-
MPU-800S-12YZ   12 VDC 12.0 - 14.0        62.50       750          ±1%         80%             tions.
                                                                                            4. Transient recovery is measured to within a 1% error band for a load step
MPU-800S-15YZ   15 VDC 15.0 - 19.0        50.00       750          ±1%         80%             change of 50% to 100%.
                                                                                            5. Isolation specifications are production HI-Pot tested for 3 seconds.
MPU-800S-24YZ   24 VDC 20.0 - 26.0        40.00       800          ±1%         83%          6. The full output range (see table) is covered in the safety agency certification.
                                                                                               Standard models are factory set to the Preset voltage, but may be set to
MPU-800S-36YZ   36 VDC 27.0 - 36.0        29.63       800          ±1%         83%             other levels within the range without affecting the agency certification. For
                                                                                               more information, contact the factory.
MPU-800S-40YZ   40 VDC 37.0 - 47.0        21.62       800          ±1%         83%          7. Output power is given for the factory preset voltage. With the exception
                                                                                               of the "12" & "15" models, the maximum continuous output power level
MPU-800S-48YZ   48 VDC 48.0 - 60.0        16.67       800          ±1%         83%             is 800W with 25 CFM airflow. All models provide a peak power level of
                                                                                               900W for a maximum duration of 500 µS. For more information, contact
                                                                                               the factory.
                                                                                            8. Each unit includes an input fuse (250V/12A). Since this fuse is not field
 Model Number                                                                                  replaceable, it is recommended that an external fuse of the same size be
                                                                                               used on the input of the power supply for protection.




                                                                                                                             Connections
                                                                                                                             Input Connector (CN1):
                                                                                                                             · Terminal Block:
                                                                                                                               Howder HD-121-3P: M3.5 Screws
                                                                                                                               3 pins, 9.5 mm Centers
Mechanical Dimensions                                                                                                        · Molex Mating Part No:
                                                                                                                               Molex 09-91-7000 or equivalent
                                                                                                                               (two pins removed)

                                                                                                                               Pin         Function
                                                                                                                                 1          AC-Line
                                                                                                                                 2        AC-Neutral
                                                                                                                                 3       Field Ground
                                                                                                                             Output Connector (CN2):
                                                                                                                             · Terminal Block:
                                                                                                                               Howder HD-121-8P: M3.5 Screws
                                                                                                                               8 pins, 9.5 mm Centers
                                                                                                                             · Molex Mating Part No:
                                                                                                                               Molex 09-91-2000 or equivalent

                                                                                                                                      Howder                       Molex
                                                                                                                                  Pin      Function          Pin        Function
                                                                                                                                  1-4       +VOUT          1-10          +VOUT
                                                                                                                                  5-8       -VOUT          10-20         -VOUT
                                                                                                                             Logic Signal Connector (CN3):
                                                                                                                             · Mating Part No:
                                                                                                                               JST XHP-7 or equivalent
                                                                                                                               (CHYAO SHIUNN JS-2001-07)

                                                                                                                                   Pin           Function
                                                                                                                                     1       + Remote Sense
                                                                                                                                     2       - Remote Sense
U-Chassis Cover (C Suffix)                                                                                                           3       Remote On/Off
                                                                                                                                     4         Power Good
                                                                                                                                     5          Common
                                                                                                                                     6        Current Share
                                                                                                                                     7       Current Monitor

                                                                                                                             Fan Driver Connector (CN4):
                                                                                                                             · Mating Part No:
                                                                                                                               JST XHP-2 or equivalent
                                                                                                                               (CHYAO SHIUNN JS-2001-2)

                                                                                                                                   Pin           Function
                                                                                                                                     1              Minus
                                                                                                                                     2              Plus




                   MicroPower Direct                                                                       Notes:
                                                                                                           · All dimensions are typical in inches (mm)
                                                                                                           · Tolerance x.xx = ±0.02 (±0.50)
                   We Power Your Success - For Less!
                   292 Page Street Ste D Stoughton, MA 02072   ·
                                                                   CompuMess Elektronik GmbH(781) 344-8481 · E-Mail: sales@micropowerdirect.com
                                                                      TEL: (781) 344-8226 · FAX:
                                                                                                     · Lise-Meitner-Str. 4 · D-85716 Unterschleißheim
                                                                   Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                   info@compumess.de · www.compumess.de · www.netzteile.de