Hier Klicken für das PDF Dokument!!!

California Instruments MX Series II                                                                             15­135 kVA

Overview                                                                                                          150­400 V
· High Power AC and DC Power Source
  Programmable AC and DC power for frequency                                                                 0­375 A / Phase
  conversion and product test applications
· Expandable Power Levels                                                                                       208   230   400
  Available output power of 15, 30, and 45 kVA
  per unit and multi-unit configurations for power
  requirements up to 135 kVA and above
                                                                                                                480
· Single and Three Phase Mode
  Phase mode programming on MX30-3Pi and
  MX45-3Pi allows switching between single and
  three phase output modes
· Arbitrary & Harmonic Waveform
  Generation
  User defined voltage waveform and
  distortion programming                               USB and LAN remote control interfaces and
                                                       instrument drivers for popular ATE programming
· Regenerative, bidirectional "Green"
                                                       environments are available. This allows the MX
  Power Solution
                                                       Series to be easily integrated into an automated
  Automatic crossover between Source and Sink
                                                       test system.
  power mode offers regenerative capabilities in AC,
  AC+DC and DC modes. Regenerate up to 100%            For advanced test applications, the programmable
  of the rated output power back to the utility grid   controller version offers full arbitrary waveform
  during sink mode operation. ( -SNK option )          generation, time and frequency domain
                                                       measurements, and voltage and current
· Remote Control
                                                       waveform capture.
  Standard RS232C & USB along with optional IEEE-
  488 & LAN Interfaces are available for automated     Configurations
  test applications                                    The MX15 delivers up to 15 kVA of single phase
                                                       output. The MX30 delivers up to 30 kVA, and the
Introduction                                           MX45 up to 45 kVA. Both operate using single
The MX Series consists of multiple high power AC       or three phase output in AC mode. In DC mode,
and DC power systems that provide controlled           50% of the AC power level is available. On MX-P
AC and DC output for ATE and product test              models, AC+DC mode is also supported.
applications.
                                                       For higher power requirements, the MX90 and
This high power AC and DC test system covers a         MX135 models are available. Multi cabinet
wide spectrum of AC and DC power applications          MX45 systems always operate in three phase
at an affordable cost. Using state-of-the-art PWM      output mode. Available reconfigurable MX90
switching techniques, the MX series combines           and MX135 models (-MB designation) provide
compactness, robustness and functionality in a         multiple controllers which allow separation of the
compact floor-standing chassis, no larger than         high power system into two or three individual
a typical office copying machine. This higher          MX45 units for use in separate applications. This
power density has been accomplished without            ability to reconfigure the system provides an even
the need to resort to elaborate cooling schemes        greater level of flexibility not commonly found in
or additional installation wiring. Simply roll the     power systems.
MX15, MX30, or MX45 unit to its designated
                                                       Product Evaluation and Test
location (using included casters), plug it in, and
                                                       Increasingly, manufacturers of high power
the MX series is ready to work for you.
                                                       equipment and appliances are required to fully
Simple Operation                                       evaluate and test their products over a wide
The MX Series can be operated completely from          range of input line conditions. The built-in output
its menu driven front panel controller. A backlit      transient generation and read-back measurement
LCD display shows menus, setup data, and               capability of the MX Series offers the convenience
read-back measurements. IEEE-488, RS232C,              of a powerful, and easy to use, integrated test
                                                       system.

          CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                  858.458.0223                             sales@ProgrammablePower.com
             Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de                   217
      MX Series II
                     Regenerative, bidirectional "Green"                     ranges are required, the programmable range
                     Power Solution                                          change option (-R) provides the ability to switch
                     The MX Series features the ability to both source       between both output ranges. Pi version models
                     and sink current, i.e. bi-directional current           offer standard dual voltage ranges.
                     flow. The MX amplifier is designed to reverse
                                                                             For applications requiring more than 300 V
                     the phase relationship between the AC input
                                                                             L-N (or 520 V L-L), the optional -HV output
                     voltage and current in order to feed power back
                                                                             transformer provides an additional 400 V L-N
                     onto the utility grid. This mode of operation is
                                                                             and 693 V L-L output range for use in AC mode
                     particularly useful when testing grid-tied products
                                                                             only.
                     that feed energy back onto the grid. Static
                     Power Converters such as grid-tied and off-grid         Multi-Box Configurations
                     photovoltaic inverters are tested for frequency         For high power applications, two or three
                     variations, voltage transients, DC injection and        MX45 chassis can be combined to provide 90
                     harmonic susceptibility.                                to 135 kVA of three phase power. MX90 and
                                                                             MX135 systems are always configured for three
                                                                             phase operation. Contact sales for custom
                                                                             configurations.
                                                                             High Crest Factor
                                                                             With a crest factor of up to 3.6, the MX Series
                     Programming sink (-SNK) mode operation
                                                                             AC source can drive difficult nonlinear loads with
                     Avionics                                                ease. Since many modern products use switching
                     With an output frequency range to 819 Hz                power supplies, they have a tendency to pull
                     (or 1000 Hz with -HF option), the MX Series is          high repetitive peak currents. The MX30-3Pi can
                     well suited for aerospace applications. Precise         deliverup to 240 Amps of repetitive peak current
                     frequency control and accurate load regulation          (150 V AC range) per phase to handle three
                     are key requirements in these applications. The         phase loads.
                     available IEEE-488 remote control interface
                                                                             Remote Control
                     and SCPI command language provide for easy
                                                                             Standard RS232C & USB IEEE-488 along with
                     integration into existing ATE systems. The MX
                                                                             optional LAN remote control interfaces allow
                     Series eliminates the need for several additional
                                                                             programming of all instrument functions from an
                     pieces of test equipment, saving cost and space.
                                                                             external computer. The popular SCPI command
                     Instrument drivers for popular programming
                                                                             protocol is used for programming.
                     environments such as National Instruments
                     LabViewTM are available to speed up system              Application Software
                     integration.                                            Windows® application software is included.
                                                                             This software provides easy access to the power
                     Regulatory Testing
                                                                             source's capabilities without the need to develop
                     As governments are moving to enforce product
                                                                             any custom code. The following functions are
                     quality standards, regulatory compliance testing
                                                                             available through this GUI program:
                     is becoming a requirement for a growing number
                     of manufacturers. The MX Series is designed               · Steady state output control (all parameters)
                     to meet AC source requirements for use in                 · Create, run, save, reload and print
                     compliance testing such as IEC 61000, 3-2, 3-3,             transient programs
                     3-11, 3-12, to name a few.                                · Generate and save harmonic waveforms.
                                                                               · Generate and save arbitrary waveforms.
                     Choice of voltage ranges
                                                                               · Measure and log standard measurements
                     The MX30 and MX45 can be ordered with either
                                                                               · Capture and display output voltage and
                     a 150 V RMS Line to Neutral output voltage
                                                                                 current waveforms.
                     range or a 300 V RMS Line to Neutral range. This
                                                                               · Measure, display, print and log harmonic
                     provides 3 phase output capability of 260 Vac or
                                                                                 voltage and current measurements.
                     520 Vac line to line respectively. If dual output
                                                                               · Display IEEE-488, RS232C, USB and LAN bus
                                                                                 traffic to and from the AC Source to help you
                                                                                 develop your own test programs.
                                                                             1. Requires PC running WindowsXPTM or Windows 2000TM.




218                                                           www.ProgrammablePower.com
MX Series II                                                                                                       15­135 kVA



                                                              Harmonically distorted waveform.

                                                              MX Series - AC and DC Transient Generation
                                                              The MX Series controller has a powerful AC
                                                              and DC transient generation system that allows
                                                              complex sequences of voltage, frequency and
                                                              waveshapes to be generated. This further
                                                              enhances the MX's capability to simulate AC line
                                                              conditions or DC disturbances. When combined
Harmonic Waveform Generation                                  with the multiphase arbitrary waveform
Using the latest DSP technology, the MX                       capabilities, the AC and DC output possibilities
Series programmable controller is capable of                  are truly exceptional. Transient generation is
generating harmonic waveforms to test for                     controlled independently yet time synchronized
harmonics susceptibility. The Windows Graphical               on all three phases. Accurate phase angle control
User Interface program can be used to define                  and synchronized transient list execution provide
harmonic waveforms by specifying amplitude and                unparalleled accuracy in positioning AC output
phase for up to 50 harmonics. The waveform                    events.
data points are generated and downloaded by
the GUI to the AC source through the IEEE-488 or              Transient programming is easily accomplished
RS232C bus. Up to 200 waveforms can be stored                 from the front panel where clearly laid out menu's
in nonvolatile memory and given a user defined                guide the user through the transient definition
name for easy recall.                                         process.

All MX-Pi Series configurations offer three phase             The front panel provides a convenient listing
waveform generation, allowing independent                     of the programmed transient sequence and
phase anomalies to be programmed. It also                     allows for transient execution Start, Stop,
allows simulation of unbalanced harmonic line                 Abort and Resume operations. User defined
conditions.                                                   transient sequences can be saved to non-volatile
                                                              memory for instant recall and execution at a
Arbitrary Waveform Generation                                 later time. The included Graphical User Interface
Using the provided GUI program or custom                      program supports transient definitions using
software, the user also has the ability to define             a spreadsheet-like data entry grid. A library
arbitrary AC waveforms. The arbitrary waveform                of frequently used transient programs can be
method of data entry provides an alternative                  created on disk using this GUI program.
method of specifying AC anomalies by providing
specific waveform data points. The GUI program
provides a catalog of custom waveforms and also
allows real-world waveforms captured on a digital
oscilloscope to be downloaded to one of the
many AC source's waveform memories. Arbitrary
                                                              Transient List Data Entry from the front panel.
waveform capability is a flexible way of simulating
the effect of real-world AC power line conditions
on a unit under test in both engineering and
production environments.




Harmonic waveform, Fund., 3rd, 5th, 7th, 9th,11th and 13th.




Two hundred user defined waveforms.                           Transient List Data Entry in GUI program.


                      858.458.0223                                          sales@ProgrammablePower.com                     219
      MX Series II
                     MX Series - Measurement and Analysis                           Waveform Acquisition
                     The MX Series is much more than a                              The measurement system is based on real-time
                     programmable AC, DC or AC+DC power source.                     digitization of the voltage and current waveforms
                     It also incorporates an advanced digital signal                using a 4K deep sample buffer. This time domain
                     processor based data acquisition system that                   information provides detailed information on
                     continuously monitors all AC source and load                   both voltage and current waveshapes. Waveform
                     parameters. This data acquisition system forms                 acquisitions can be triggered at a specific phase
                     the basis for all measurement and analysis                     angle or from a transient program to allow
                     functions. These functions are accessible from the             precise positioning of the captured waveform
                     front panel and the remote control interface for               with respect to the AC source output.
                     the MX Series (MX15 excluded; uses 2-line display
                                                                                    The front panel LCD displays captured waveforms
                     shown below).
                                                                                    with cursor readouts (excluding MX15). The
                     Conventional Measurements [All controllers]                    included GUI program also allows acquired
                     Common AC and DC measurement parameters                        waveform data to be displayed, printed, and
                     are automatically provided by the data acquisition             saved to disk.
                     system. These values are displayed in numeric
                     form on the front panel LCD display. The
                     following measurements are available: Frequency,
                     Vrms, Irms, Ipk, Crest Factor, Real Power (Watts),
                     Apparent Power (VA) and Power Factor.
                     Harmonic Analysis
                     The MX Series provides detailed amplitude and                  Acquired Current waveform (MX30/45 Display).
                     phase information on up to 50 harmonics of
                     the fundamental voltage and current (up to 16
                     kHz in three phase mode) for either one or three
                     phases. Harmonic content can be displayed
                     in both tabular and graphical formats on the
                     front panel LCD for immediate feedback to the                  Acquired Voltage waveform (MX30/45 Display).
                     operator (excluding MX15). Alternatively, the
                     included GUI program can be used to display,
                     print and save harmonic measurement data. Total
                     harmonic distortion of both voltage and current is
                     calculated from the harmonic data.
                                                                                    Measurement data for single phase (MX30/45 Display).




                     Absolute amplitude bar graph display of current harmonics      Measurement data for all three phases (MX30/45 Display).
                     with cursor positioned at the fundamental (MX30/45 Display).




                     Voltage harmonic measurement table display in absolute
                     values (MX30/45 Display)




                                                                                    Acquired three phase voltage waveforms display on PC.




220                                                               www.ProgrammablePower.com
MX Series II : Specifications                                                                                                                                         15­135 kVA
Operating Modes
Pi Version                                       AC, DC and AC+DC
AC Mode Output
Frequency                                        Range: 16.00-819.0 Hz, -LF Option: 16.00-500.0 Hz, -HF Option: 16.00-1000 Hz (supplemental specifications apply above
                                                 819 Hz). Resolution: 0.01 Hz: 16.00 - 81.91 Hz, 0.1 Hz: 82.0 Hz - 819.1 Hz, 1 Hz: 820-1000 Hz
Phase Outputs                                    MX15-1/15-1Pi: 1, MX30/45-3Pi: 1 or 3 switchable, Neutral: Floating, Coupling: DC (except for -HV option)
Total Power                                      MX15-1/1Pi: 15 kVA, MX30-1/3: 30 kVA, MX45-1/3: 45 kVA, MX90: 90 kVA, MX135: 135 kVA
Load Power Factor                                0 to unity at full output current
AC Mode Voltage
Voltage Ranges                                    Range       V Low         V High               Load Regulation     < 0.25 % FS DC to 100 Hz, < 0.5 % FS 100 Hz to 819 Hz
                                                  AC          0-150 V       0-300 V              Line Regulation     < 0.1% FS for 10 % line change
                                                  AC+DC       0-150 V       0-300 V

External Sense                                   Voltage drop compensation (5% Full Scale)
Harmonic Distortion (Linear)                     Less than 0.5% from 16 - 66 Hz, Less than 1% from 66 - 500 Hz, Less than 1.25% above 500 Hz
DC Offset                                        < 20 mV
Load Regulation                                  0.25% FS @ DC - 100 Hz, 0.5% FS > 100 Hz
External Amplitude Modulation                    Depth: 0 - 10 %, Frequency: DC - 2 KHz
Voltage slew rate                                200 µs for 10% to 90% of full scale change into resistive load, 0.5V / µSec
AC Mode Current
Steady State AC Current @ FS V                   Model MX15-1Pi MX30-3Pi / 1Pi MX45-3Pi / 1Pi MX90-3/Pi MX135-3/Pi
                                                 V Low 100             66.6/ø / 200     100/ø / 300         200/ø       300/ø
                                                 V High 50             33.3/ø / 100     50/ø / 150          100/ø       150/ø
                                                 Note: Constant power mode provides increased current at reduced voltage. See chart below

Peak Repetitive AC Current                       Up to 3.6 x rms current at full scale voltage
Programming Accuracy                             Voltage (rms): ± 0.3 Vrms, Frequency: ± 0.01 % of programmed value, Current Limit: - 0 % to + 5 % of programmed value + 1A, Phase:
                                                 < 0.5° + 0.2°/ 100 Hz with balanced load
Programming Resolution                           Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819 Hz, Current Limit: 0.1 A, 3 phase mode,
                                                 1.0 A, 1 phase mode, Phase: 0.1°
Constant Power AC Mode - Available Max. AC Current
                               125%

                    Current
                    (RMS) 100%


                                                                                                                                          Full
                                50%                                                                                                      Power


                                20%



                                           10%                                               50%                                80%                  100%

                                                                                                                              Voltage (RMS)




 Note: Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase
   for a sinewave with a resistive load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under
   balanced load conditions only.

 © 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen,
   California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.



                        858.458.0223                                                      sales@ProgrammablePower.com                                                                            221
      MX Series II : Specifications
      Measurement
      Measurements - Standard                Parameter         Frequency      RMS       RMS         Peak        Crest     Real         Apparent    Power     Phase     DC                DC         Power
      (AC Measurements)                                                       Voltage   Current     Current     Factor    Power        Power       Factor              Voltage           Current
                                             Range             16-100 Hz      0-400 V   0-160 A     0-400 A     0.00-6.00 0-15 kW      0-15 kVA    0.00-1.00 0.0-360.0 0-400 V           0-160 A    Power
                                                               100-820 Hz
                                             Accuracy*         0.01% +    0.05 V + 0.15 A +         0.15 A + 0.05            30 W +    30 VA +     0.01         2.0°             0.5 V   0.5 A      0.15 kW
                                                (±)               0.01 Hz    0.02%    .02%             0.02%                    0.1%      0.1%

                                                                              0.1 V +  0.3 A +  0.3 A +  0.05                60 W +    60 VA +     0.02         3.0°
                                                                                 0.02%    0.02%    0.02%                        0.1%      0.1%
                                             Resolution* 0.01 Hz /            10 mV    10 mA    10 mA    0.01                10 W      10 VA       0.01         0.1°             10 mV   10 mA      10 W
                                                            0.1 Hz
                                             * Measurement system bandwidth = DC to 6.7 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy and Range specifications are
                                                times three for MX90, MX135 or MX30/45-3Pi in single phase mode. PF accuracy applies for PF > 0.5 and VA > 50 % of range

      Measurements - Harmonics               Parameter              Frequency Fundamental Harmonics           Phase          Voltage                                   Current
      (Pi controller only)                   Range                  16.00-1000.0 Hz / 32.00 Hz - 16 kHz       0.0 - 360.0°   Fundamental Harmonics 2-50                Fundamental Harmonics 2-50
                                             Accuracy* (±)          0.03% + 0.03 Hz / 0.01 Hz                 2° typ.        750 mV 0.3% + 750 mV+0.3% /1 kHz          0.5 A / 0.3% + 150 mA +0.3% /1 kHz
                                             Resolution             0.01 Hz                                   0.5°           10 mV / 10 mV                             100 mA / 100 mA

                                             * Accuracy specifications are valid above 100 counts. Accuracy specifications are for three phase mode. Harmonics frequency range for MX30/45-3Pi in single phase
                                                mode is 32 Hz - 48 kHz

      DC Mode Output
      Power                                  Maximum DC power at full scale of DC voltage range. MX15-1Pi: (10 kW), MX30-3Pi: (6.5 kW per output, 3 outputs. 20 kW in
                                             1 channel mode), MX45-3Pi: (10 kW per output, 3 outputs. 30 kW in 1 channel mode)
      Voltage Ranges                         Range: Low (0 - 200 V), High (0 - 400 V)
      Output Accuracy                        ± 1 Vdc
      Load Regulation                        < 0.25 % FS
      Line Regulation                        < 0.1% FS or 10 % line change
      Ripple                                 < 2 Vrms Lo Range, < 3 Vrms Hi Range
      Max DC Current @ FSV per output        Model        MX15-1Pi MX30-3Pi / 1Phs MX45-3Pi / 1Phs MX90-3/Pi MX135-3/Pi
                                             V Low        50               33.3 / 100             50 / 150              100            150
                                             V High 25                     16.6 / 50              25 / 75               50             75
                                             Note: Constant power mode provides increased current at reduced voltage. See chart on previous page

      Current Limit                          Programmable from 0 A to max. current for selected range
      AC+DC Mode Output
      Output (Pi) Power                      Maximum current and power in AC+DC mode is same as DC mode
      Protection
      Over Load                              Constant Current or Constant Voltage mode
      Over Temperature                       Automatic shutdown
      Storage
      Non Volatile Mem. storage              16 instrument setups, 200 user defined waveforms [Pi only]
      Waveforms
      Waveform Types                         Std: Sine, Pi: Sine, Square, Clipped sine, User defined
      User defined waveform storage          Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200. One group can be active at a time
      System Interface
      Inputs                                 Remote shutdown, External Sync, Clock/Lock
      Outputs                                Function Strobe / Trigger out, Clock/Lock
      Remote Control (Pi standard with -P option)
      IEEE-488 Interface                     IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax
      RS232C Interface                       9 pin D-shell connector (Supplied with RS232C cable)
      LAN ( option )                         Ethernet Interface: 10BaseT, 100BaseT, RJ45
      USB                                    Version: USB 1.1; Speed: 460 Kb/s maximum
      Output Relay                           Push button controlled or bus controlled output relay
      Output impedance                       Programmable Z available on MX30-3Pi and MX45-3Pi in 3 phase mode only. Specifications apply at 50 Hz fundamental.
        ( not available with -SNK Option )   Resistive: 1 - 200 mOhm, Inductive: 15 - 200 uH



222                                                                                                            www.ProgrammablePower.com
MX Series II : Specifications                                                                                                                                15­135 kVA
AC Input
Voltage                                     Must be specified at time of order. All inputs are L-L, 3ø, 3 wire + Gnd. 208 ± 10% VAC, 230 ± 10% VAC, 400 ± 10% VAC,
                                            480 ± 10% VAC
Input Line Current (per phase)              Current (MX15):                                                      Current (MX30/45):
                                            V L-L        208          230           400          480             V L-L   208             230                400            480
                                            St State     58.3 ARMS 52.3 ARMS 30 ARMS 25 ARMS                     St State 116/175 ARMS 105/157 ARMS 60/90 ARMS 50/75 ARMS
                                            Distortion: < 8 % at full power < 20 % below 35 % of power

Line Frequency                              47 - 63 Hz
Efficiency                                  85 % typical
Power Factor                                0.95 typical
AC Service
Inputs/Outputs                              MX30/MX45: Front access, cables routed through rear panel, exit in back. MX15: Rear Access
Regulatory                                  IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
EMI                                         CISPR 11, Group1 , Class A
Connectors                                  AC Input & Output terminal block behind front cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, (rear
                                              panel), Remote voltage sense terminal block (rear panel), System Interface Connector, DB-37 (rear panel). *RS232 DB9 to DB9 cable
                                              supplied
Physical Dimensions
MX30/MX45 Dimensions                        Height: 50.0" (1270 mm), Width: 28.75" (731 mm), Depth: 34.5" (876 mm)
MX30/MX45 Weight                            Chassis: Net: 1150 lbs / 522 Kg, Shipping: 1231 lbs / 560 Kg, Amp Module: Net: 63 lbs / 29 Kg
MX15 Dimensions                             Height: 31.75" (806 mm), Width: 24.0" (610 mm), Depth: 28.0" (711 mm)
MX15 Weight                                 Chassis: Net: 600 lbs / 272 Kg, Shipping: 681 lbs / 309 Kg, Amp Module: Net: 63 lbs / 29 Kg
Chassis                                     MX30/MX45: Casters and forklift openings. MX15: Casters
Vibration and Shock                         Designed to meet NSTA project 1A transportation levels. Units are shipped in wooden crate with forklift slots
Air Intake/Exhaust                          Forced air cooling, front air intake, rear exhaust
Operating Humidity                          0 to 95 % RAH, non condensing
Temperature                                 Operating: 0 to 40° C (30° C max in CP mode), Storage:                -20 to +85° C
Programmable controller versions with dual voltage ranges
Model                                               AC Output Power                        Phase Outputs                    AC/DC Voltage Range                      Controller
MX15-1Pi                                                   15kVA                                  1                         150/200 & 300/400                      Programmable
MX30-3Pi                                                   30 kVA                                1&3                        150/200 & 300/400                      Programmable
MX45-3Pi                                                   45 kVA                                1&3                        150/200 & 300/400                      Programmable
MX90-3Pi                                                   90 kVA                                 3                         150/200 & 300/400                      Programmable
MX135-3Pi                                                  135 kVA                                3                         150/200 & 300/400                      Programmable
Pi models include IEEE-488, RS232C & USB interfaces, Advanced measurements, arbitrary waveform generation. Phase mode switching on MX-30/45-3Pi.
-MB Option
Model                                               AC Output Power                        Phase Outputs                    AC/DC Voltage Range                      Controller
MX90-3Pi-MB                                                90 kVA                                 3                         150/200 & 300/400                     Dual MX45-3Pi
MX135-3Pi-MB                                               135 kVA                                3                         150/200 & 300/400                     Triple MX-45-3Pi
Reconfigurable systems can be separated into stand-alone MX45-3Pi models or combined for higher power levels.

Steady State AC RMS Current in Regeneration Mode ( -SNK Option )
Model                                            MX15-1Pi                   MX30-3Pi                  MX45-3Pi             MX60-3Pi               MX90-3Pi                MX135-3Pi
V Low                                               100A                 66.6/Ø / 200             100A/Ø/300                133.3/Ø                200/Ø                    300/Ø
V High                                              50A                  33.3/Ø / 100             50A/Ø/150                  66.6/Ø                100/Ø                    150/Ø




                       858.458.0223                                                    sales@ProgrammablePower.com                                                                    223
      MX Series
                                           Model                                                  -413          *IEC 1000-4-13 Harmonics &
                                           Refer to table shown for model numbers and                           Interharmonics test firmware.
                                           configurations.
                                                                                                  -704          Mil Std 704 A - F test - firmware/ software.
                                           Supplied with
                                                                                                  -ABD          ABD0100.1.8 Test Option.
                                           Standard: User Manual on CD ROM.
                                           Pi version: User/Programming Manual and Software       -AMD          Airbus AMD24 Test
                                           on CD ROM. RS232C serial cable.                        -A350         Airbus Test Software
                                           Input Voltage Settings                                 -B787         Boeing 787 Test Software
                                           Specify input voltage (L-L) setting for each MX
                                           system at time of order:                               -HV           Adds 400 V L-N AC-only output range.
                                           208 Configured for 208 V ±10 % L-L,                    -LF           Limits max. frequency to 500 Hz.
                                                4 wire input.
                                           230 Configured for 230 V ±10 % L-L,                    -HF           Increases max. frequency to 1000 Hz.
                                                4 wire input.                                     -XV           Adds other AC-only output range.
                                           400 Configured for 400 V ±10 % L-L,                                  Consult factory.
                                                4 wire input.
                                           480 Configured for 480 V ±10 % L-L,                    -LKM          Clock/Lock Master
                                                4 wire input                                      -LKS          Clock/Lock Auxiliary
                                           Standard Model Options                                 -WHM          Watt-Hour Measurement option.
                                           Specify output range on standard models. All
                                           range values shown are Line to Neutral.                -SNK          Bidirectional auto source and sink mode.
                                                                                                                Offers up to 100% power sink capability.
                                           - 150     Configured for 150 V AC and
                                                     200 V DC output ranges.                      Packaging and Shipment

                                           - 300     Configured for 300 V AC and                  All MX systems are packaged in re-usable protective
                                                     400 V DC output ranges.                      wooden crates for shipment.

                                           Pi Model Options                                           Feature Comparison
                                           -160    RTCA/DO-160D, DO-160E, and                         Model                                Pi
                                                   EUROCAE test firmware.                             AC mode                              X
                                                                                                      DC mode                              X
                                           -411      *IEC 1000-4-11 test firmware.
                                                                                                      AC+DC mode                           X
                                           - LF      Limits maximum frequency to 500 Hz.              Dual V Range                         X
                                           -P        IEEE-488 & RS232C Interface Adds                 Transient programming                X
                                                     programming, Windows & RS232 Cable.              Arbitrary waveforms                  X
                                                                                                      Measurements                         X
                                           -LAN      Ethernet Interface.                              Harmonic measurements                X
                                           - HF      Increases max frequency to 1000 Hz.              Waveform acquisition                 X
                                                                                                      1 or 3 Phase mode                MX30/45-3Pi
                                           -R        Range change. Provides 150/200 & 300/            IEEE / RS232                         X
                                                     400 AC/DC output ranges. (Std. MX15)

       MX15 Dimensions - single chassis                                           MX30/MX45 Dimensions - single chassis
                                        31.75                                                 28.75
                                       [806.45]                                              [730.25]




                                                                                                                                                 48.125
                                                                                                                                                [1222.4]




                                   00
                                28. .20]
                               [ 711                                  0
                                                                 24.0 0]
                                                                     .8
                                                                [609
                                                                                                                                                  1.95
                   Rear View                            Front View                                                                               [49.53]
                                                                                          Rear View                           Front View




224                                                                              www.ProgrammablePower.com