Hier Klicken für das PDF Dokument!!!

! Portable Power, Low Cost.
    Portable solution for wide range of AC
                                                                             Portable AC Power
    power tests.
! 810 VA to 1250 VA Output Power
                                                                                       P Series
    Capable of handling most single phase                                           LOW COST
    applications.                                                                 PROGRAMMABLE
! Simple Front Panel Operation                                                      AC POWER
    Analog style controls and digital read-
    outs for key functions.
! 16 Hz to 500 Hz Frequency
  Range
    Utility and Avionics applications.
! High Peak Current Capability
    Drives a wide variety of non-linear
    loads.
! Remote Control Option
    Ideal for Automated test
    applications.


Compact AC Power                             onics applications. The current mea-             The output frequency can be varied
   With European and US outlet sock-         surement function eliminates the need         from 16 Hz up to 500 Hz to cover both
ets to connect the load, the 801P,           for an external current shunt or trans-       avionics and utility power applications.
1001P and 1251P portable program-            former. Load current of the UUT (Unit
mable AC power sources are ideal for
                                                                                           Product Evaluation and Test
                                             Under Test) can be read directly on the
a wide variety of applications               large LCD display to 0.1 A. For addi-         Applications
   Universal input allows use anywhere       tional protection, a current limit function       Traditional Variac tests can be auto-
in the world to provide a convenient         can be set from zero to the maximum           mated using the P Series AC sources.
source of variable utility power for the     current available.                            With digital voltage readout, and mea-
testing and evaluation of domestic and          High peak current capability of more       surement of load current, several items
commercial equipment. All common             than three times the RMS current al-          of equipment can be eliminated from
line voltage and frequency combina-          lows the P Series to drive non-linear         `first time power up' tests. All functions
tions are covered.                           loads.                                        are contained in a single convenient
   In addition, the frequency range cov-                                                   and easily portable package, which
ers 500 Hz, making these products            Easy To Use Controls                          can be most useful in production ap-
ideal for commercial and defense avi-          Front panel digital rotary encoders are     plications.
                                                             used to set voltage and
                                                             frequency. These con-         Avionics Applications
                                                             trols have an analog            As affordable and reliable sources
                                                             feel, with the precision      of 400 Hz AC power, the 801P, 1001P
                                                             and reliability of digital    and 1251P are well suited for commer-
                                                             circuits. Settings are        cial and defense avionics applications.
                                                             read directly on the
                                                             large high contrast LCD       Remote Control
                                                             displays.                        Equipped with the optional RS232C
                                                                Both models offer two      serial interface, these units are easily
                                                             output voltage ranges,        integrated into an ATE system. A Win-
                                                             135 VRMS L-N and 270          dowsTM Graphical User Interface (GUI)
                                                             VRMS L-N, maximizing          program is included for PC control ap-
                                                             the current at the re-        plications.
                                                             quired voltage.
WindowsTM Graphical User Interface software included
Low Cost Of Ownership                             Specifications*                                        801P 1001P 1251P             Unit
  Careful design, the use of modular              Controller
construction and quality components, all              Type                                                      Programmable
contribute to provide many years of un-               Controls                                                 Digital Encoders
                                                      Readout                          Voltage                   4 digit LCD
interrupted service. The modular con-                                                  Freqency                  4 digit LCD
struction allows components or subas-                                                  and Current
semblies to be replaced quickly to mini-               Non Volatile Setups (with Option -232)                            8
mize downtime.                                    Output
                                                       AC Power                                           810      1000       1250    VA
Ordering Information                                   Voltage
                                                       Range                           low                           0 - 135          V (L-N)
Models:                                                                                high                          0 - 270          V (L-N)
 801P       810 VA AC Source                           Accuracy                        @ 50/60 Hz                      ±1             % FS
 1001P      1000 VA AC Source                                                          @ 400 Hz                        ±2             % FS
 1251P      1250 VA AC Source                          Resolution                                                      0.1            V
                                                       Line & Load Regulation          lo range                        ±1             % FS
Options                                                                                hi range                        ± 0.5          % FS
 -232       Optional RS232C Interface.                 Total Harmonic Distortion       @ 50/60 Hz                    < 0.55           % typical
            Includes WindowsTM                         Output Noise                                                   < 0.1           V typical
            Graphical User Interface                   Frequency                (specifications valid from 45 Hz to 500 Hz)
            software and serial cable                  Range                                                        16 - 500          Hz
                                                       Accuracy                                                      ± 0.02           %
  -ISS      International Socket Strip
                                                       Resolution                      below 100 Hz                    0.1            Hz
  -ISR      Rackmounted ISS                                                            above 100 Hz                      1            Hz
                                                       Current
Line Cord Options:
                                                       Current - Steady State          lo range             6.0        7.4      9.2   ARMS
  Country          801P/1001P     1251P                                                hi range             3.0        3.7      4.6   ARMS
  Europe             PC11          PC11                Peak Current                    lo range            17.8      22.2      27.6   A
  Australia /                                                                          hi range             8.9      11.1      13.8   A
  New Zealand         PC12         PC12           Protection
  UK / Ireland        PC13         PC13                Current limit                   Mode                      Programmable
  Denmark             PC14         PC14                                                Resolution                      0.1            ARMS
                                                       Over Temperature                                                yes
  India               PC15         PC15
                                                       Over Voltage                                                    yes
  Israel              PC16         PC16           Input
  Italy               PC17         PC17                Line Voltage                    2 wire + GND             100 - 240 ±10 %       VRMS
  North America*      PC21         PC18                Input Current                                       <15      < 15       < 20   ARMS
  Switzerland         PC19         PC19                Line Frequency                                                47 - 63          Hz
  Japan               PC20         PC20                Holdup Time                                                      20            ms
                                                       Power Factor                                                  > 0.95           typical
* One North American Line cord is included.
                                                  Measurements
Supplied with:                                         Current                         Range                       0.0 - 10.0         ARMS
                                                                                       Accuracy                       ± 0.2           ARMS
  · North American Line Power Cord                                                     Resolution                      0.1            A
  · USA and European line output                       Voltage                         Range                         0 - 278          V
    mating connector                                   (requires Option -232)          Resolution               1 (below 250 V)       V
  · Instruction Manual                            Remote Control Option -232
Terms:                                                 Interface type                                               RS232C
     Net 30 days on approved credit                    Baud rate                                                      9600
                                                       Command Language                                               SCPI
Delivery:                                         Physical
     30 days ARO                                       Dimensions                      HxWxD                    8.25 x 8.5 x 17.5     inches
Shipment:                                                                              HxWxD                    210 x 216 x 445       mm
     F.O.B. San Diego, CA. Freight                     Weight                                                       30 / 13.6         lbs / kg
     collect.                                          Operating Temp.                                                0 - 40          °C
                                                 * Specifications are warranted over an ambient temperature range of 0 to 40 °C and apply
Customer Support                                   after a 30 minute warmup period.
  For technical support and service, or
to discuss your AC power application
                                                                                 Contact California Instruments:
needs, contact California Instruments
Corp. at (858) 677-9040 or your local                                                                 858 677-9040
          CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
representative.                                                                                 FAX: 858-677-0940
                                                                                        Email: sales@calinst.com
            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
                                                                                                Web page: http://www.calinst.com


9689 Towne Centre Drive, San Diego, CA 92121-1964                          (858) 677-9040                              FAX : (858) 677-0940
© Copyright 1999, California Instruments Corp.   Specifications subject to change without notice      Printed in the USA.             PSDS 11/01