Hier Klicken für das PDF Dokument!!!

·   Programmable Power, Low Cost                                             Program AC Power
    Cost effective solution for wide range of AC
    power tests                                                                  Worldwide
·   800 VA or 1250 VA Output Power                                          Model 801RP / 1251RP
    Capable of handling most single phase appli-
    cations
·   Front and Rear Outputs
    Connect load to front panel outlets or rear
    panel terminal block for maximum conve-
    nience
·   16 Hz to 500 Hz Frequency Range
    Utility and Avionics applications
·   High Peak Current Capability
    Drives a wide variety of non-linear loads
·   Remote Control Option
    IEEE-488 and RS232C Interface for auto-
    mated test applications



Compact AC Power                           Easy To Use Controls                        Quality Control
With European and US outlet sock-          Front panel digital rotary encoders         For product quality test applications,
ets to connect the load, the 801RP         are used to set voltage and fre-            the 801RP and 1251RP can be used
and 1251RP programmable AC                 quency. These controls have an ana-         to simulate line conditions found any-
power sources are ideal for a wide         log feel, with the precision and reli-      where in the world. This ensures
variety of applications.                   ability of digital circuits. Settings are   products destined for export will op-
Universal, Power Factor Corrected          read directly on the large high con-        erate as designed.
(PFC) input allows these products to       trast LCD displays.
be used anywhere in the world to pro-      Dual output voltage ranges of 135           Avionics Applications
vide a convenient source of variable       Vrms L-N and 270 Vrms L-N, provide          As an affordable and reliable source
utility power for the testing and evalu-   maximum current at the required volt-       of 400 Hz AC power, both units are
ation of domestic and commercial           age.                                        well suited for commercial and de-
equipment. All common line voltage         The output frequency can be varied          fense avionics applications. Both unit
and frequency combinations are cov-        from 16 Hz up to 500 Hz to cover            can easily be integrated into avion-
ered.                                      both avionics and utility power appli-      ics ATE systems.
In addition, the frequency range cov-      cations.
ers 500 Hz, making these products                                                      Functional Design
ideal for commercial and defense avi-      IEC 1000-3-2 Test                           The small form factor and low weight
onics applications.                        Applications                                of these units make them convenient
A built in current measurement func-                                                   to use in a variety of locations. Re-
                                           The low total harmonic distortion of
tion eliminates the need for an exter-                                                 movable rubber feet protect the work
                                           the output makes the 801RP and
nal current shunt or transformer. Load                                                 surface if the unit is used in a bench
                                           1251RP suitable AC sources for IEC
current of the UUT (Unit Under Test)                                                   top mode. The 3.5 inch height saves
                                           1000-3-2 Current Harmonics pre
can be read directly on the large LCD                                                  valuable rack space when compared
                                           compliance testing. Loads requiring
display to 0.1 A. For additional pro-                                                  to conventional AC power sources at
                                           up to 4.6 Arms at 230 Vrms with peak
tection, a current limit function can                                                  this power level.
                                           currents up to 12 A can be tested
be set from zero to the maximum
                                           with the 1251RP while the 801RP can
current rating.
                                           supply up to 3.0 Arms. This covers
                                           many loads that fall under the IEC
                                           standard.
801RP / 1251RP - Easy Transient Programming
                                            Extensive Transient Control1
                                            With the addition of the remote control interface option, 801RP and
                                            1251RP units are capable of producing transients with a high degree
                                            of user programmability. Setting up transient programs is facilitated
                                            by a Windows Graphical User Interface program that allows ampli-
                                            tude, frequency and event duration to be programmed from a PC.
                                            Time resolution is 1 ms (0.001 sec) with a minimum time interval
                                            ranging from 10 to 40 ms, depending on the transient type. Transient
                                            programming allows the effects of common line disturbances such
                                            as voltage surges, sags, drop-outs and frequency fluctuations on the
                                            unit under test to be evaluated.
Drop transient causes output voltage to     Remote or Local Operation
drop to zero for a user specified period.
                                            For automated test equipment (ATE) applications, the RP Series
                                            units can be outfitted with both IEEE-488 and RS232C using the -IF
                                            option. A front panel lock out mode is supported on both models if
                                            operator interaction with the AC source is not required or desired.

                                            SCPI Protocol Programming Commands
                                            All functions of the 801RP and 1251RP are completely program-
                                            mable over the IEEE-488 or RS232C bus. For example, the
                                            following tasks can be performed over the bus:
                                            · Set voltage to any level
                                            · Change frequency
                                            · Generate 10 ms or longer voltage dropouts
Voltage Surge transient causes output       · Measure rms current, voltage and apparent power
voltage to surge                            · Recall eight complete instrument setups from non-volatile
                                                 memory with a single SCPI command
                                            · Reset the instrument
                                            · Adjust current limit value
                                            · Lock the front panel to prevent operator interference
                                            · Switch between high and low voltage range
                                            · Turn output on and off

                                            Application Software
                                            Windows 98TM or Windows 2000TM application software is included
                                            with the remote control interface option. This easy to use graphical
                                            interface program provides complete control over all instrument func-
                                            tions using either the RS232C or IEEE-488 interface. With enhanced
Frequency Sweep transient at a user         capabilities such
specified rate.                             as data logging to
                                            file and Dynamic
                                            Data Exchange to
                                            other W indows
                                            programs, many
                                            applications can
                                            be addressed
                                            without the need
                                            for writing custom
                                            code.



                                                                 Free WindowsTM Graphical User Interface
                                                                 software included with interface option.
Voltage Sweep transient causes output
voltage to change at a programmed rate.      1
                                                 Note: Transient control does not apply to output phase angle
                                                                                     Specifications
    Parameter                                           801RP                          1251RP            Unit
    Controller
       Type                                                     Programmable
       Controls                                                 Digital Encoders
       Readout                           Voltage                   4 digit LCD
                                 Freq. / Current                   4 digit LCD
       Non Volatile Setups      (with -IF option)                       8
    Output
       AC Power                                           800                           1250              VA
       Voltage
       High range / Low Range                                     0 - 270 / 0 - 135                     V (L-N)
       Accuracy                     @ 50/60 Hz                           ±1                              % FS
                                     @ 400 Hz                            ±2                              % FS
       Resolution                                                        0.1                               V
       Line & Load Regulation     High V range                          ± 0.5                            % FS
                                   Low V range                           ±1                              % FS
       Line Regulation        10 % Line change                          ± 0.1                            % FS
       T.H.D.                       @ 50/60 Hz                       0.5 typical                           %
       Output Noise                                                 < 0.1 typical                          V
       Frequency                                    (specifications valid from 45 Hz to 500 Hz)
       Range                                                           16 - 500                           Hz
       Accuracy                                                         ± 0.02                            %
       Resolution                 below 100 Hz                           0.1                              Hz
                                  above 100 Hz                             1                              Hz
       Current
       Steady State Current       High V range           3.0                             4.6            A rms
                                  Low V range            6.0                             9.2            A rms
       Peak Current               High V range           13.8                            13.8           A peak
       (shorted output)           Low V range            27.6                            27.6           A peak
    Protection
       Current limit                      Mode               Programmable trip level                Output trips off
       (Output shut off)            Resolution                        0.1                               A rms
       Over Temperature                                          Output shut off
       Over Voltage                                              Output shut off
    Input
       Line Voltage1              2 wire + GND                      100 -240                             V rms
                      Maximum operating range                       85 - 265                             V rms
       Line Current (fused)                                           < 15                               A rms
       Line Frequency                                                47 - 63                              Hz
       Holdup Time                                                     20                                 ms
       Power Factor                                               > 0.95 typical
       Isolation              Input to Chassis                        1350                                 V
                                Input to Output                       2200                                 V
    Measurements
       Current (RMS steady state)        Range                      0.0 - 10.0                           A rms
                                       Accuracy                       ± 0.2                              A rms
                                    Resolution                          0.1                                A
       Voltage                           Range                       0 - 278                               V
                                    Resolution                   1 (below 250 V)                           V
    Remote Control Option
       Interface types                option -IF                   RS232C
                                                                  IEEE-488
       IEEE-488 Address                                              0 - 31
       IEEE Functions                                  SH1, AH1, T8, L3, RL2, SRQ0, PP0
       RS232C settings                                            9600,8,n,1
       Command Language                                              SCPI
    Physical
       Regulatory                                                       CE
       Dimensions                        HxWxD                   3.5 x 16.8 x 22                        inches
                                         HxWxD                   89 x 427 x 560                           mm
       Weight (net)                                                 34 / 15.4                           lbs / kg
       Vibration and Shock                                 Designed to meet NSTA-1A
       Temperature                    Operating               0 to 40 / - 40 to + 85                      °C

1
 120 Vrms minimum line input required for full 1250 VA output on model 1251RP.
Note: Specifications are warranted for an ambient temperature of 23° + 5° C and apply after a 30 minute warmup period.
    Remote Control                                Line Cord Options:                           Higher Power Models
    The RP Series can be ordered with a             Country               Part No.
    combined RS232C and IEEE-488 re-                Continental Europe        PC1
    mote control interface option. A Win-           Australia / New Zealand PC2
    dows Graphical User Interface (GUI)             UK / Ireland etc.         PC3
    program is included with either op-
                                                    Denmark                   PC4
    tion for PC control applications.
                                                    India                     PC5
    Ordering Information                            Israel                    PC6
                                                    Italy                     PC7
    Models:                                         Switzerland               PC9           A 2000 VA version of the RP Series
    801RP          800 VA rack-mount AC             North America*           PC10           is available in both single and three
                   source                         * One North American Line cord is
                                                                                            phase output configurations. Refer to
    1251RP         1250 VA rack-mount             included. Optional line cords are         the 2001RP and 2003RP catalog
                   AC Source                      straight, adding about 1 inch of depth to pages for details.
    Options:                                      unit.
                                                                                               Portable AC Sources
    -FN            Floating Neutral               Supplied with:
                   output.                   · North American Line Power Cord
    -IF            IEEE-488 and RS232C · USA and European line output
                   Interface                       mating connector
    -ISS           International Socket      · Instruction Manual
                   Strip                     · WindowsTM Graphical User
    -ISR           Rack mounted ISS                Interface and RS232C cable (with
    -L22           Locking knobs                   -IF option)
    -RI            Remote Inhibit Input (Req. -IF)
    -RMS           Rack Slides (P/N
                   210367)
                                                                                               For mobile or bench top applications,
                                                                                               1000 VA portable AC power sources
       801RP / 1251RP Dimension drawing
                                                                                               are available as well. The 1001P of-
                                                                                               fers similar capabilities as the 801RP
                                                                                               at an increased power level. For ap-
                                                                                               plications that only require fixed volt-
                                                                                               age and frequency settings, the
                                                                                               1001WP frequency converter pro-
                                                                                               vides push button selection of nomi-
                                                                                               nal 50 or 60 Hz and 100V, 115V,
                                                                                               220V, 230V and 240 V settings. Re-
                                                                                               fer to P and WP Series catalog pages
                                                                                               for details.




                                                                                                 Contact California Instruments:
                                                                                                       CompuMess Elektronik GmbH
                                                                                                                     TEL: 858 677-9040
                                                                                              Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                                     FAX: 858-677-0940
                                                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                                   info@compumess.desales@calinst.com
                                                                                                             Email: · www.compumess.de
                                                                                                     Web page: http://www.calinst.com
                                                                                                              www.netzteile.de




9689 Towne Centre Drive, San Diego, CA 92121-1964                         (858) 677-9040                              FAX : (858) 677-0940
© Copyright 1999, California Instruments Corp.   Specifications subject to change without notice      Printed in the USA.           RPDS 03/04