Hier Klicken für das PDF Dokument!!!

                                                                                DC Power Supplies
                               By California Instruments                              XDS Series


·   Compact Modular DC Power
    Uses less rack space compared to
    other DC supplies of similar power
    level. Modular construction supports
    5, 10 and 15 KW versions.
·   Wide Range of Applications
    Telecommunications, automotive,
    industrial and commercial applica-
    tions.
·   Built-in Measurements
    Voltage, current and power
    readback capability standard.
·   Fast Transient Response
    Capable of driving demanding loads.
·   Parallel / Current Share Capability
    Paralleled chassis can deliver up to
    75 KW.
·   Standard RS232C Interface and
    Optional GPIB.
    Instrument drivers and software
    support for easy system integration.


Compact Power                            Easy To Use Controls                   Applications
The XDS Series packs up to 15 KW         Simple menu driven operation and       With excellent output regulation and
of DC power into a 5.25" rack mount      familiar rotary controls for setting   accuracy, the XDS Series DC
chassis. Despite the high power          voltage and current ensures that the   Power Supplies support a wide
density of this design, the XDS          XDS Series Power Supplies are          variety of DC power applications.
Series provides a low noise, stable      easy to operate. All front panel       Examples include communications,
output.                                  controls including the rotary knobs    semiconductors, automotive,
A full set of measurements is built-in   are digitally encoded for long         information technology and indus-
to provide instant feedback on EUT       lasting, trouble free operation. The   trial. The standard RS232C serial
load characteristics.                    voltage and current control knobs      interface supports remote control of
                                         can be used to quickly slew output     all power supply functions and
The XDS Series offers all the basic      parameters.                            measurements and allows for easy
DC power supply capabilities                                                    integration into ATE systems. Use
needed for a wide range of applica-      The intuitive front panel controls
                                         allow for easy operation of the        of standard SCPI command lan-
tions and provides cost effective                                               guage syntax and instrument
alternative to larger and more           supply by both novice and experi-
                                         enced users alike.                     drivers for popular programming
expensive products typically used                                               environments further ease system
for these applications.                                                         integration. An optional GPIB
                                                                                interface is available as well.

        CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
           Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
  XDS Series - GUI Software
All XDS Series Power Supplies come with Windows
GUI software. This GUI program offers additional
functionality. This includes the following capabilities:
Output Sequencing: Time driven output changes can
be programmed, stored and executed under program
control. Events include steps, sweeps, drops and
surges of voltage and/or current. This allows a variety of
power conditions and DC tests to be set up without
having to develop application specific code. Multiple
setups can be stored on disk.
Data Logging: All measurements taken from the DC
supply can be recorded to disk in a format that is easily
exported to other programs such as MS Excel for
analysis and display.
Pass/Fail Testing: Automatic output sequencing and
data readback with user defined pass/fail criteria. This
mode may be used for burn-in or product evaluation
applications. A simple to use spreadsheet-like user
interface allows entry of time delays, settings, readings         Graphical user interface DC supply control program.
and pass/fail limits. Any number of setups can be saved
to disk for future use.
The GUI program operates over the standard RS232C
interface or the optional IEEE-488/GPIB interface and
provides comprehensive on-line help.


  XDS Series - Models1
                                 Output                                                          Output

 Model            Voltage        C urrent        R MS N oise       Model            Voltage      C urrent   R MS N oise

 XD S 30-167       0-30           0-167             15mv           XD S 150-33       0-150        0-33         25mv

 XD S 30-333       0-30           0-333             15mv           XD S 150-66       0-150        0-66         25mv

 XD S 30-500       0-30           0-500             15mv           XD S 150-100      0-150       0-100         25mv

 XD S 40-125       0-40           0-125             15mv           XD S 300-17       0-300        0-17         100mv

 XD S 40-250       0-40           0-250             15mv           XD S 300-33       0-300        0-33         100mv

 XD S 40-375       0-40           0-375             15mv           XD S 300-50       0-300        0-50         100mv

 XD S 50-100       0-50           0-100             15mv           XD S 400-12       0-400       0-12.5        100mv

 XD S 50-200       0-50           0-200             15mv           XD S 400-25       0-400        0-25         100mv

 XD S 50-300       0-50           0-300             15mv           XD S 400-37       0-400        0-37         100mv

 XD S 80-62        0-80            0-62             25mv           XD S 600-8        0-600         0-8         250mv

 XD S 80-125       0-80           0-125             25mv           XD S 600-17       0-600        0-17         250mv

 XD S 80-187       0-80           0-187             25mv           XD S 600-25       0-600        0-25         250mv

 XD S 100-50      0-100            0-50             25mv

 XD S 100-100     0-100           0-100             25mv

 XD S 100-150     0-100           0-150             25mv

Note 1: Contact factory for availability of models with output voltage ranges not listed here.
 XDS Series - Specifications
Electrical                                                 Measurements Cont.
Output                                                     Voltage
Power                                                        Model                 Resolution           Accuracy
                                                             XDS 400-XXX           0.1 V                0.5 V
  Maximum               5, 10 or 15 KW                       XDS 600-XXX           0.2 V                1.0 V
Voltage
                                                           Current
  Accuracy:             0.3 % FS                             Current Range         Resolution           Accuracy
  Resolution:           0.033 % FS                           0 - 8.3 A             0.003 A              0.013 A
  Line Regulation:      < 0.1% of V range                    0 - 16 A              0.005 A              0.025 A
  Load Regulation:      < 0.1% of V range                    0 - 33 A              0.01 A               0.05 A
  Transient Response:   Voltage will recover to within       0 - 66 A              0.02 A               0.1 A
                        2% of V range within 2 msec          0 - 187 A             0.1 A                0.3 A
                        for 30 % load step.                  0 - 400 A             0.1 A                0.5 A
  Stability:            ± 0.05% of max. rating per 8         0 - 600 A             0.2 A                1A
                        hours after 30 mins. warmup        Power
                        period.                              Range                 Resolution           Accuracy
Current                                                      0 - 5 KW              1W                   0.3 % FS
  Accuracy:             0.5% FS at 0-100% of range           0 - 10 KW             2W                   0.3 % FS
  Resolution:           0.1%-0.033 % (model specific)        0 - 15 KW             5W                   0.3 % FS
  Line Regulation:      < 0.1% of I range                  Peak Current
  Load Regulation:      < 0.1% of I range                    Resolution:           See current table
  Stability:            ± 0.05% of max. rating per 8         Accuracy:             Same as current + 3 x resolu-
                        hours after 30 mins. warmup                                tion.
                        period.
                                                           Protection
Input
                                                            Over temperature, short circuit, over current protec-
  Voltage:              208 - 10 % to 230 + 10% VAC
                                                            tion
                        400 ± 10 % VAC (option -400)
                        480 ± 10 % VAC (option -480)       Controls and Indicator
                        All inputs are L-L, 3 phase, 3-
                        wire plus safety ground.           Controls
  Current RMS:          Typical RMS current per              Voltage setting:      Digitally encoded rotary knob
                        phase at low line input voltage.     Current setting:      Digitally encoded rotary knob
                                                             Measurement select:   Push button
                                                             Output on/off:        Push button
                                Power Level                  Power on/off:         Toggle switch
                        Vlow    5 kW 10 kW 15 kW
                                                           Indicators
                        187 V: 27 A       54 A    81 A
                                                             Display:              Dual 7 segment large LED
                        360 V: 15 A       30 A    45 A       LED's for:            Output on/off, cc mode, cv
                        432 V: 12A        24 A    36 A                             mode, remote, measurements.
  Power Factor:         > 0.65
                                                           Remote Control
  Efficiency:           > 85 % at full load.
                                                           A standard RS232C and analog RPV (0-10 VDC) are
Measurements                                               included with all XDS Series DC Power Supplies. An
                                                           optional GPIB/IEEE-488 input is available as well.
Voltage
  Model                 Resolution             Accuracy    RS232C - Standard
  XDS 30-XXX            0.01 V                 0.05 V        9 pin D-shell connector, 19200 baud, SCPI syntax
  XDS 40-XXX            0.01 V                 0.05 V
  XDS 50-XXX            0.02 V                 0.1 V
                                                           RPV Input - Standard
  XDS 80-XXX            0.02 V                 0.1 V         Input:                0-10 VDC for 0-100% range
  XDS 100-XXX           0.1 V                  0.2 V         Connector:            15 pin D-sub.
  XDS 150-XXX           0.1 V                  0.3 V       Remote Inhibit - Standard
  XDS 300-XXX           0.1 V                  0.5 V         Programmable for default high or low
  XDS Series - Specifications

-IF Option                                               Mechanical
IEEE-488 Interface                                       Dimensions
  IEEE-488 (GPIB) talker listener.                         Height:                5.25" / 133.35 mm
  Subset:              AH1, L3, RL2, SH1, T8               Width:                 19" / 482.6 mm
                       IEEE-488.2 SCPI syntax              Depth:                 22.19" / 563.3 mm excl. bus
                                                                                  bars and cover
Environmental                                                                     24.74" / 628.4 mm incl. bus
Temperature Coefficient                                                           bars and cover
  Voltage set point:    0.02%/°C of V Range              Weight                   15 KW           10 KW             5KW
  Current set point:    0.03%/°C of I Range                Net:                   90 lbs.         70 lbs.           50 lbs.
Ambient Temperature                                                               41 Kg           32 Kg             23 Kg
  Operating:            0° to 40° C / 32° to 104° F        Shipping (approx.):    125 lbs.        105 lbs.          85 lbs.
  Storage:              -40° to 75° C / -40° to 167° F                            57 Kg           48 Kg             39 Kg

Humidity                                                 Rack Mounting
  Operating:            0 to 80% RH, non condensing        Unit must be supported by shelf or brackets when
                                                           mounted in 19" cabinet. No provisions for rack slides
Cooling                                                    are made on instrument.
  Forced air, side and top intake, rear exhaust.


  XDS Series - Ordering Information
                                                         Optional Configurations
Ordering Information
                                                         -AUX        Auxilliary control.
Model
                                                         -RPV5       Remote voltage programming, 0-5 volt
All XDS Series model numbers specify voltage and
current range.                                           -RPV10      Remote voltage programming, 0-10 volt
XDS VVV-CCC-LLL-XX-XXXXX                                 -RPC5       Remote current programming, 0-5 volt
        VVV = Voltage                                    -RPC10      Remote current programming, 0-10 volt
        CCC = Current                                    Ordering Examples:
        LLL = Input Line Voltage                         Model                    Description
        XX = Options                                     XDS 50-100-208           Output voltage range is 50 Vdc,
        XXXXX = Configuration                                                     maximum current is 100 Adc,
                                                                                  line input is 208 V line to line,
Refer to table shown for model numbers and configura-
                                                                                  three phase. Includes standard
tions.
                                                                                  RS232C and analog interfaces.
Includes                                                 XDS 80-187-400-IF        Output voltage range is 80 Vdc,
User manual and programming manual on CD ROM.                                     maximum current is 187 Adc,
Windows GUI software on CD ROM.                                                   line input is 400 V line to line,
                                                                                  three phase. Includes optional
RS-232C serial cable                                                              IEEE/RS232 and analog
Options                                                                           interfaces.
-IF         GPIB / IEEE-488 interface programming
            option.
-400        400 ±10% volt line to line AC input
-480        480 ±10% volt line to line AC input




                                 For more information call:
                                 TEL: 858 404-6936 Email: sales@argantix.com                 © Copyright 2003, Argantix. San Diego, California, USA
                                                                                             Specifications subject to change without notice
                                 FAX: 858 677-0940 Web: www.argantix.com                     Printed in the USA                       DS XDS 02/05