Sorensen XG 1700 Series 1700 W
1700 Watt, 1U Programmable DC Power Supplies 6600 V
· Industry Leading Power Density
Up to 1700 Watts in 1U 2.8220 A
· Standard Digital Interfaces USB&RS232/485
· LXI Ethernet and Isolated analog interfaces 110 220
· Power Factor Correction-PFC and
universal AC input
· "Green" Sleep Mode Automatically "sleeps"
after period of non-use
· Built in sequencing - Unload your system controller
· Programmable fold-back protection delay
The XG 1700 is an industry leading programmable DC Variable Fan Speed Control
power supply designed for test, production, laboratory, The XG 1700's innovative approach to fan speed is
OEM and quality assurance applications. The XG 1700 determined by internal heat sink temperature. This allows
is a 1700 Watt, 1U programmable power supply with the fans to adjust to a constant optimal speed when the
constant voltage and constant current modes, automatic output of the supply is being pulsed. This also reduces
cross-over and numerous features enabling cost effective, noise and increases fan life.
easy integration.
Power Saving Standby Mode
When the XG 1700 has been in an idle state, the supply
Key Features
can go into "sleep mode", much like a computer monitor.
Easy Integration This will allow the user to save energy and minimize lab
XG 1700 has many control and indication signals such as noise. Since an XG 1700 left in sleep mode is still "on"
shutdown, constant voltage (CV) vs. constant current (CC) the user will have quicker access to an enabled output.
mode indication, OVP, OCP, OTP, and so on. In addition,
Key Modes
the logical-high or -low is free selectable. Thus enabling
the XG 1700 to replace existing power supplies with little Output Auto Start Mode (Auto Restart)
or no system engineering required. The Auto Start mode establishes the state of the output
of the power supply after recovery from a complete
Free selectable analog control range
power cycle (all front panel LEDs are not illuminated), or
Most DC power supplies provide a 0 to 5 or 0 to 10 V
after recovery from a PC failure or reboot. If Auto Start
analog control range to control the DC output from zero
mode is set to On, the power supply output will return
to full DC output range. With the XG 1700, the analog
to its previous value. Also, after the loss of any remote
control range is free selectable starting at 0V to an upper
digital control, the XG unit will remain active in its last
range between 2V and 10V. In other words, the analog
programmed setting and will not disrupt any test process.
programming interface range is freely adjustable.
Auxiliary Auto Start Mode
Auxiliary DC output channels with control
The Auxiliary Auto Start mode determines the state of the
In many ATE systems one or more low power, fixed voltage AMETEK
auxiliary output after a complete power cycle (all front
supplies are needed to provide electrical power for any Programmable Power
panel LEDS are not illuminated). With Auxiliary Auto Start
periphery within the ATE cabinet. For this purpose, the 9250 Brown Deer Road
mode turned to On, the auxiliary output will be activated
XG 1700 provides two standard auxiliary DC output San Diego, CA 92121-2267
after the power supply is powered up again.
channels. Both auxiliary power channels are controllable USA
directly from the front-panel or through SCPI commands. Foldback Mode
With these channels, it is possible to drive output- Foldback mode is used to disable the output when a
disconnect or polarity-reversal relays, without needing a transition is made between the operating modes. The
complicated computer controlled relay board. power supply will turn off/disable the output and lock in
foldback mode after a specified delay if the power supply
DC-waveforms through internal sequencing
transitions into CV mode or into CC mode, depending
To allow for extremely fast programming, sequences can
on the foldback mode settings. This feature is particularly
be programmed into and stored in memory using standard
useful for protecting current or voltage sensitive loads.
SCPI commands through USB, RS-232/485, LXI or GPIB.
Foldback can be set to trigger a switch when transitioning
from CV to CC mode or from CC to CV mode.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
858.458.0223 sales@ProgrammablePower.com
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
XG 1700 Series : Product Specifications 1700 W
Output
Models Output Voltage 1 Output Current 2 Output Power 3
XG 6-220 6V 220 A 1330 W
XG 8-200 8V 200 A 1610 W
XG 12-140 12 V 140 A 1690 W
XG 20-84 20 V 84 A 1690 W
XG 33-50 33 V 50 A 1660 W
XG 40-42 40 V 42 A 1690 W
XG 60-28 60 V 28 A 1690 W
XG 80-21 80 V 21 A 1690 W
XG 100-17 100 V 17 A 1710 W
XG 150-11.2 150 V 11.2 A 1690 W
XG 300-5.6 300 V 5.6 A 1690 W
XG 600-2.8 600 V 2.8 A 1690 W
Line Regulation Voltage Line Regulation Current Load Regulation Voltage Load Regulation Current
Models (0.005% of rated output (0.01% of rated output (0.005% of rated output (0.02% of rated output
voltage +2 mV) 4 current +2 mA) 5 voltage + 2 mV) 6 current +5 mA) 7
XG 6-220 2.3 mV 24 mA 2.3 mV 49 mA
XG 8-200 2.4 mV 22 mA 2.4 mV 45 mA
XG 12-140 2.6 mV 16 mA 2.6 mV 33 mA
XG 20-84 3.0 mV 10.4 mA 3.0 mV 22 mA
XG 33-50 3.7 mV 7 mA 3.7 mV 15 mA
XG 40-42 4 mV 6.2 mA 4 mV 13 mA
XG 60-28 5 mV 4.8 mA 5 mV 10.6 mA
XG 80-21 6 mV 4.1 mA 6 mV 9.21 mA
XG 100-17 7 mV 3.7 mA 7 mV 8.4 mA
XG 150-11.2 9.5 mV 3.12 mA 9.5 mV 7.2 mA
XG 300-5.6 17 mV 2.56 mA 17 mV 6.1 mA
XG 600-2.8 32 mV 2.28 mA 32 mV 5.6 mA
Output Noise (rms, 300 kHz) Output Ripple (p-p, 20 MHz)
Models Voltage Current 8 Voltage
XG 6-220 8 mV 200 mA 50 mV
XG 8-200 8 mV 170 mA 50 mV
XG 12-140 8 mV 120 mA 50 mV
XG 20-84 8 mV 75 mA 50 mV
XG 33-50 8 mV 60 mA 50 mV
XG 40-42 8 mV 45 mA 50 mV
XG 60-28 8 mV 35 mA 50 mV
XG 80-21 8 mV 25 mA 80 mV
XG 100-17 8 mV 20 mA 80 mV
XG 150-11.2 10 mV 16 mA 100 mV
XG 300-5.6 25 mV 10 mA 150 mV
XG 600-2.8 50 mV 6 mA 250 mV
1. Minimum output voltage is guaranteed to be 0.2% of the rated voltage at zero output setting.
2. Minimum output current is guaranteed to be 0.4% of the rated current at zero output setting when measured with rated load resistance.
3. Total output power is also based on AUX1 Output Voltage (5V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
4. From 85-132 Vac or 170-265 Vac, constant load.
5. From 85-132 Vac or 170-265 Vac, constant load.
6. From no load to full load, constant input voltage.
7. For load voltage change, equal to the unit voltage rating, constant input voltage.
8. For 6 V models the ripple is measured at 2-6 V output voltage and full output current. For other models, the ripple is measured at 10-100% output voltage and full output current.
Note: All specifications are subject to change.
www.ProgrammablePower.com
XG 1700 Series : Product Specifications
11
Maximum Recommended Remote Sense 10 Efficiency
Model Line Drop Compensation per Line 9
Up-prog. Response Time, 0~Vmax
(100/200 VAC input)
XG 6-220 1V 60 ms 76/78%
XG 8-200 1V 60 ms 77/79%
XG 12-140 1V 60 ms 81/84%
XG 20-84 1.5 V 60 ms 82/85%
XG 33-50 2V 60 ms 83/86%
XG 40-42 2V 60 ms 83/87%
XG 60-28 3V 60 ms 84/88%
XG 80-21 5V 100 ms 84/88%
XG 100-17 5V 100 ms 84/88%
XG 150-11.2 5V 100 ms 84/88%
XG 300-5.6 5V 150 ms 84/88%
XG 600-2.8 5V 250 ms 84/88%
Model Down-prog. Response Time: Full Load* Down-prog. Response Time: No Load* Over-Voltage Trip Point
XG 6-220 50 ms 300 ms 0.57.5 V
XG 8-200 50 ms 400 ms 0.510 V
XG 12-140 50 ms 500 ms 115 V
XG 20-84 50 ms 600 ms 124 V
XG 33-50 50 ms 700 ms 239 V
XG 40-42 50 ms 800 ms 244 V
XG 60-28 50 ms 900 ms 366 V
XG 80-21 80 ms 1000 ms 395 V
XG 100-17 100 ms 1200 ms 3125 V
XG 150-11.2 150 ms 1800 ms 3180 V
XG 300-5.6 150 ms 2200 ms 5330 V
XG 600-2.8 250 ms 3500 ms 5660 V
9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with 1 V of load line loss (0.5 V/Line), the
maximum available load voltage would be 6-1=5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee That the power supply will meet performance specifications. Ultimately, the upper limit
of the output voltage will be determined by internal circuitry of the power supply (non-adjustable)
10. With rated, resistive load.
11. At 100/200 Vac input voltage and maximum output power.
Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GP1B, Ethernet optional. Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power.
* Typical
Note: All specifications are subject to change.
858.458.0223 sales@ProgrammablePower.com
XG 1700 Series : Product Specifications 1700 W
AC Line Input Specifications
Rated AC Input Voltage/Frequency 100240 Vac, 4763 Hz
Operational AC Input Voltage/Frequency 85265 Vac continuous, 4763 Hz, single phase
Input Current (at 100/200 Vac) 23/12 A
Inrush Current (100/200 Vac) Less than: 50 A
Power Factor Correction 0.99@100/200 Vac, rated output power
Programming Mode APG ISOL Digital
Voltage & Current Output 0-100% 2~up to 10 V, programmable
Voltage Programming
Voltage & Current Output 0-100% 2~up to 10 k, programmable
Resistive Programming
Voltage Output Resistor Programming 0-100% 2~up to 10 k, programmable
Output Voltage and Current Monitor 0-100% 2~up to 10 V, programmable
± 0.5% of rated output voltage,
Voltage Programming Accuracy (mV)1 max (0-4V/4K range) ± 0.1% of rated output voltage
± 1% of rated output current,
Current Programming Accuracy (mV)1 max (0-4V/4K range) ± 0.2% of rated output current
Voltage Readback Accuracy (mV) ± 1% of rated output voltage ± 0.1% of rated output voltage
Current Readback Accuracy (mV) ± 1% of rated output current ± 0.2% of rated output current
With respect to:
chassis potential: 500 V
Isolation (Prog and Readback Lines) With respect to chassis potential: 500 V
negative or positive main output 1500 V
negative or positive auxiliary output 300 V
Voltage and Current
0.012% of full scale
Programming Resolution
Voltage and Current
Readback Resolution
Parallel Operation Up to 4 units in master / slave
Series Operation Up to 2 units (with external diodes)
Constant Voltage (CV) Constant CV: TTL High (4-5 V)
Current (CC) Indicator CC TTL Low (0-0.6 V)
Logic low 0.0 - 1.4 V
Shutdown Control 2 Logic high 2.0 - 15 V
Dry contact compatible
AUX On/Off Control TTL level or dry contact compatible
Power Supply Status Signal TTL high: OK (4-5 V)
TTL low: fail (0-0.6 V)
Dry contact. Open/Short: On or
Interlock Enable/Disable
Off programmable
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected
2. The shutdown input has user selectable negative logic operation via front panel or remote digital input/output
Note: All specifications are subject to change.
www.ProgrammablePower.com
XG 1700 Series : Product Specifications
Output Performance Specifications
Temperature Coefficient 100 PPM/° C from rated output voltage, after a 30-minute warm-up*
Drift (8 hours) 0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up
Hold-up Time Typical 20 ms at any rated input line.
1
Transient Response Time Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models*
Meter Accuracy 0.5% ± 1 count
Isolation
AC Input to Output 1350 Vac
1350 Vac
AC Input to Chassis
Environmental Specifications (Indoor use)
Operating Temperature Range 32°F to 122°F, 100% load (0°C to 50°C)
Storage Temperature Range -4°F to 158°F (20° C to 70°C)
Operating Humidity Range 3090% RH (no condensation)
Storage Humidity Range 1095% RH (no condensation)
Operating Altitude Up to 6,500 feet (2,000 m)
Installation Category II (IEC 1010-1)
Pollution Degree 2 (IEC 1010-1)
Regulatory Approvals
Safety CSA 22.2 No. 61010-1 and UL61010-1. Marked with c(UL) us, CE EN61010-1
EMC Complies with EN55022, Class A, FCC Part 15A for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity
Mechanical Specifications
XG 1700 Watt (W×H×D) 16.8 x 1.7 x 19.0 inch (429 x 43.6 x 483 mm without rack mount ears)
Weight 22 lb (10 kg)
Cooling Forced air cooling by internal fans
* Typical
1. Time for the output voltage to recover within 0.05% at its rated output for a load change 10-90% of rated ouput current. Output set point 10-100%
Note: All specifications are subject to change.
Model Number Description
XG 33 50 (XXX)
Series Options
Voltage Current
XG Options
MEA LXI Class C ETHERNET
MGA GPIB, IEEE 488.2
XG Options and Accessories
RM - XG1 Rackmount Angle Brackets
858.458.0223 sales@ProgrammablePower.com
XG 1700 Series : Product Diagram 1700 W
www.ProgrammablePower.com