Sorensen XG 1700 Series                                                                                                                  1700 W
1700 Watt, 1U Programmable DC Power Supplies                                                                                            6­600 V
· Industry Leading Power Density
   ­ Up to 1700 Watts in 1U                                                                                                         2.8­220 A
· Standard Digital Interfaces ­ USB&RS232/485
· LXI Ethernet and Isolated analog interfaces                                                                                             110          220
· Power Factor Correction-PFC and
   universal AC input
· "Green" Sleep Mode ­ Automatically "sleeps"
   after period of non-use
· Built in sequencing - Unload your system controller
· Programmable fold-back protection delay



The XG 1700 is an industry leading programmable DC            Variable Fan Speed Control
power supply designed for test, production, laboratory,       The XG 1700's innovative approach to fan speed is
OEM and quality assurance applications. The XG 1700           determined by internal heat sink temperature. This allows
is a 1700 Watt, 1U programmable power supply with             the fans to adjust to a constant optimal speed when the
constant voltage and constant current modes, automatic        output of the supply is being pulsed. This also reduces
cross-over and numerous features enabling cost effective,     noise and increases fan life.
easy integration.
                                                              Power Saving Standby Mode
                                                              When the XG 1700 has been in an idle state, the supply
Key Features
                                                              can go into "sleep mode", much like a computer monitor.
Easy Integration                                              This will allow the user to save energy and minimize lab
XG 1700 has many control and indication signals such as       noise. Since an XG 1700 left in sleep mode is still "on"
shutdown, constant voltage (CV) vs. constant current (CC)     the user will have quicker access to an enabled output.
mode indication, OVP, OCP, OTP, and so on. In addition,
                                                              Key Modes
the logical-high or -low is free selectable. Thus enabling
the XG 1700 to replace existing power supplies with little    Output Auto Start Mode (Auto Restart)
or no system engineering required.                            The Auto Start mode establishes the state of the output
                                                              of the power supply after recovery from a complete
Free selectable analog control range
                                                              power cycle (all front panel LEDs are not illuminated), or
Most DC power supplies provide a 0 to 5 or 0 to 10 V
                                                              after recovery from a PC failure or reboot. If Auto Start
analog control range to control the DC output from zero
                                                              mode is set to On, the power supply output will return
to full DC output range. With the XG 1700, the analog
                                                              to its previous value. Also, after the loss of any remote
control range is free selectable starting at 0V to an upper
                                                              digital control, the XG unit will remain active in its last
range between 2V and 10V. In other words, the analog
                                                              programmed setting and will not disrupt any test process.
programming interface range is freely adjustable.
                                                              Auxiliary Auto Start Mode
Auxiliary DC output channels with control
                                                              The Auxiliary Auto Start mode determines the state of the
In many ATE systems one or more low power, fixed voltage                                                                    AMETEK
                                                              auxiliary output after a complete power cycle (all front
supplies are needed to provide electrical power for any                                                                     Programmable Power
                                                              panel LEDS are not illuminated). With Auxiliary Auto Start
periphery within the ATE cabinet. For this purpose, the                                                                     9250 Brown Deer Road
                                                              mode turned to On, the auxiliary output will be activated
XG 1700 provides two standard auxiliary DC output                                                                           San Diego, CA 92121-2267
                                                              after the power supply is powered up again.
channels. Both auxiliary power channels are controllable                                                                    USA
directly from the front-panel or through SCPI commands.       Foldback Mode
With these channels, it is possible to drive output-          Foldback mode is used to disable the output when a
disconnect or polarity-reversal relays, without needing a     transition is made between the operating modes. The
complicated computer controlled relay board.                  power supply will turn off/disable the output and lock in
                                                              foldback mode after a specified delay if the power supply
DC-waveforms through internal sequencing
                                                              transitions into CV mode or into CC mode, depending
To allow for extremely fast programming, sequences can
                                                              on the foldback mode settings. This feature is particularly
be programmed into and stored in memory using standard
                                                              useful for protecting current or voltage sensitive loads.
SCPI commands through USB, RS-232/485, LXI or GPIB.
                                                              Foldback can be set to trigger a switch when transitioning
                                                              from CV to CC mode or from CC to CV mode.
            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
               858.458.0223               sales@ProgrammablePower.com
                Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
XG 1700 Series : Product Specifications                                                                                                                                                                    1700 W
Output
Models                                                                     Output Voltage 1                                           Output Current 2                                           Output Power 3
XG 6-220                                                                            6V                                                       220 A                                                  1330 W
XG 8-200                                                                            8V                                                       200 A                                                  1610 W
XG 12-140                                                                          12 V                                                      140 A                                                  1690 W
XG 20-84                                                                           20 V                                                       84 A                                                  1690 W
XG 33-50                                                                           33 V                                                       50 A                                                  1660 W
XG 40-42                                                                           40 V                                                       42 A                                                  1690 W
XG 60-28                                                                           60 V                                                       28 A                                                  1690 W
XG 80-21                                                                           80 V                                                       21 A                                                  1690 W
XG 100-17                                                                         100 V                                                       17 A                                                  1710 W
XG 150-11.2                                                                       150 V                                                      11.2 A                                                 1690 W
XG 300-5.6                                                                        300 V                                                      5.6 A                                                  1690 W
XG 600-2.8                                                                        600 V                                                      2.8 A                                                  1690 W
                                                               Line Regulation Voltage                     Line Regulation Current                     Load Regulation Voltage                    Load Regulation Current
Models                                                         (0.005% of rated output                      (0.01% of rated output                     (0.005% of rated output                    (0.02% of rated output
                                                                   voltage +2 mV) 4                            current +2 mA) 5                            voltage + 2 mV) 6                         current +5 mA) 7
XG 6-220                                                                  2.3 mV                                      24 mA                                       2.3 mV                                  49 mA
XG 8-200                                                                  2.4 mV                                      22 mA                                       2.4 mV                                  45 mA
XG 12-140                                                                 2.6 mV                                      16 mA                                       2.6 mV                                  33 mA
XG 20-84                                                                  3.0 mV                                     10.4 mA                                      3.0 mV                                  22 mA
XG 33-50                                                                  3.7 mV                                       7 mA                                       3.7 mV                                  15 mA
XG 40-42                                                                   4 mV                                       6.2 mA                                       4 mV                                   13 mA
XG 60-28                                                                   5 mV                                       4.8 mA                                       5 mV                                  10.6 mA
XG 80-21                                                                   6 mV                                       4.1 mA                                       6 mV                                  9.21 mA
XG 100-17                                                                  7 mV                                       3.7 mA                                       7 mV                                   8.4 mA
XG 150-11.2                                                               9.5 mV                                     3.12 mA                                      9.5 mV                                  7.2 mA
XG 300-5.6                                                                17 mV                                      2.56 mA                                       17 mV                                  6.1 mA
XG 600-2.8                                                                32 mV                                      2.28 mA                                       32 mV                                  5.6 mA
                                                                                                 Output Noise (rms, 300 kHz)                                                               Output Ripple (p-p, 20 MHz)
Models                                                                           Voltage                                                   Current 8                                                Voltage
XG 6-220                                                                          8 mV                                                      200 mA                                                   50 mV
XG 8-200                                                                          8 mV                                                      170 mA                                                   50 mV
XG 12-140                                                                         8 mV                                                      120 mA                                                   50 mV
XG 20-84                                                                          8 mV                                                      75 mA                                                    50 mV
XG 33-50                                                                          8 mV                                                      60 mA                                                    50 mV
XG 40-42                                                                          8 mV                                                      45 mA                                                    50 mV
XG 60-28                                                                          8 mV                                                      35 mA                                                    50 mV
XG 80-21                                                                          8 mV                                                      25 mA                                                    80 mV
XG 100-17                                                                         8 mV                                                      20 mA                                                    80 mV
XG 150-11.2                                                                       10 mV                                                     16 mA                                                   100 mV
XG 300-5.6                                                                        25 mV                                                     10 mA                                                   150 mV
XG 600-2.8                                                                        50 mV                                                      6 mA                                                   250 mV

 1.   Minimum output voltage is guaranteed to be  0.2% of the rated voltage at zero output setting.
 2.   Minimum output current is guaranteed to be  0.4% of the rated current at zero output setting when measured with rated load resistance.
 3.   Total output power is also based on AUX1 Output Voltage (5V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
 4.   From 85-132 Vac or 170-265 Vac, constant load.
 5.   From 85-132 Vac or 170-265 Vac, constant load.
 6.   From no load to full load, constant input voltage.
 7.   For load voltage change, equal to the unit voltage rating, constant input voltage.
 8.   For 6 V models the ripple is measured at 2-6 V output voltage and full output current. For other models, the ripple is measured at 10-100% output voltage and full output current.

 Note: All specifications are subject to change.


                                                                                                                           www.ProgrammablePower.com
XG 1700 Series : Product Specifications
                                                                                                                                                                                                              11
                                                          Maximum Recommended Remote Sense                                                                         10                           Efficiency
Model                                                        Line Drop Compensation per Line 9
                                                                                                                       Up-prog. Response Time, 0~Vmax
                                                                                                                                                                                            (100/200 VAC input)
XG 6-220                                                                          1V                                                      60 ms                                                     76/78%
XG 8-200                                                                          1V                                                      60 ms                                                     77/79%
XG 12-140                                                                         1V                                                      60 ms                                                     81/84%
XG 20-84                                                                        1.5 V                                                     60 ms                                                     82/85%
XG 33-50                                                                          2V                                                      60 ms                                                     83/86%
XG 40-42                                                                          2V                                                      60 ms                                                     83/87%
XG 60-28                                                                          3V                                                      60 ms                                                     84/88%
XG 80-21                                                                          5V                                                      100 ms                                                    84/88%
XG 100-17                                                                         5V                                                      100 ms                                                    84/88%
XG 150-11.2                                                                       5V                                                      100 ms                                                    84/88%
XG 300-5.6                                                                        5V                                                      150 ms                                                    84/88%
XG 600-2.8                                                                        5V                                                      250 ms                                                    84/88%
Model                                                      Down-prog. Response Time: Full Load*                       Down-prog. Response Time: No Load*                                  Over-Voltage Trip Point
XG 6-220                                                                        50 ms                                                     300 ms                                                   0.5­7.5 V
XG 8-200                                                                        50 ms                                                     400 ms                                                   0.5­10 V
XG 12-140                                                                       50 ms                                                     500 ms                                                    1­15 V
XG 20-84                                                                        50 ms                                                     600 ms                                                    1­24 V
XG 33-50                                                                        50 ms                                                     700 ms                                                    2­39 V
XG 40-42                                                                        50 ms                                                     800 ms                                                    2­44 V
XG 60-28                                                                        50 ms                                                     900 ms                                                    3­66 V
XG 80-21                                                                        80 ms                                                    1000 ms                                                    3­95 V
XG 100-17                                                                      100 ms                                                    1200 ms                                                   3­125 V
XG 150-11.2                                                                    150 ms                                                    1800 ms                                                   3­180 V
XG 300-5.6                                                                     150 ms                                                    2200 ms                                                   5­330 V
XG 600-2.8                                                                     250 ms                                                    3500 ms                                                   5­660 V




9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with 1 V of load line loss (0.5 V/Line), the
maximum available load voltage would be 6-1=5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee That the power supply will meet performance specifications. Ultimately, the upper limit
of the output voltage will be determined by internal circuitry of the power supply (non-adjustable)
10. With rated, resistive load.
11. At 100/200 Vac input voltage and maximum output power.
Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GP1B, Ethernet optional. Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power.
* Typical

Note: All specifications are subject to change.




                             858.458.0223                                                                sales@ProgrammablePower.com
XG 1700 Series : Product Specifications                                                                                                                                                   1700 W
AC Line Input Specifications
Rated AC Input Voltage/Frequency                         100­240 Vac, 47­63 Hz
Operational AC Input Voltage/Frequency                   85­265 Vac continuous, 47­63 Hz, single phase
Input Current (at 100/200 Vac)                           23/12 A
Inrush Current (100/200 Vac)                             Less than: 50 A
Power Factor Correction                                  0.99@100/200 Vac, rated output power
Programming Mode                                         APG                                                         ISOL                                          Digital
Voltage & Current Output                                 0-100% 2~up to 10 V, programmable
Voltage Programming
Voltage & Current Output                                 0-100% 2~up to 10 k, programmable
Resistive Programming
Voltage Output Resistor Programming                      0-100% 2~up to 10 k, programmable
Output Voltage and Current Monitor                       0-100% 2~up to 10 V, programmable
                                                         ± 0.5% of rated output voltage,
Voltage Programming Accuracy (mV)1                         max (0-4V/4K range)                                                                                     ± 0.1% of rated output voltage

                                                         ± 1% of rated output current,
Current Programming Accuracy (mV)1                         max (0-4V/4K range)                                                                                     ± 0.2% of rated output current

Voltage Readback Accuracy (mV)                           ± 1% of rated output voltage                                                                              ± 0.1% of rated output voltage
Current Readback Accuracy (mV)                           ± 1% of rated output current                                                                              ± 0.2% of rated output current
                                                                                                                     With respect to:
                                                                                                                     chassis potential: 500 V
Isolation (Prog and Readback Lines)                      With respect to chassis potential: 500 V
                                                                                                                     negative or positive main output 1500 V
                                                                                                                     negative or positive auxiliary output 300 V
Voltage and Current
                                                                                                                                                                   0.012% of full scale
Programming Resolution
Voltage and Current
Readback Resolution
Parallel Operation                                       Up to 4 units in master / slave
Series Operation                                         Up to 2 units (with external diodes)
Constant Voltage (CV) Constant                           CV: TTL High (4-5 V)
Current (CC) Indicator                                   CC TTL Low (0-0.6 V)
                                                                                                                     Logic low 0.0 - 1.4 V
Shutdown Control 2                                                                                                   Logic high 2.0 - 15 V
                                                                                                                     Dry contact compatible
AUX On/Off Control                                                                                                   TTL level or dry contact compatible

Power Supply Status Signal                                                                                           TTL high: OK (4-5 V)
                                                                                                                     TTL low: fail (0-0.6 V)
                                                                                                                     Dry contact. Open/Short: On or
Interlock Enable/Disable
                                                                                                                     Off programmable
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected
2. The shutdown input has user selectable negative logic operation via front panel or remote digital input/output

Note: All specifications are subject to change.




                                                                                                                             www.ProgrammablePower.com
XG 1700 Series : Product Specifications
Output Performance Specifications
Temperature Coefficient                                100 PPM/° C from rated output voltage, after a 30-minute warm-up*
Drift (8 hours)                                        0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up
Hold-up Time                                           Typical 20 ms at any rated input line.
                                 1
Transient Response Time                                Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models*
Meter Accuracy                                         0.5% ± 1 count
Isolation
AC Input to Output                                     1350 Vac
                                                       1350 Vac
AC Input to Chassis
Environmental Specifications (Indoor use)
Operating Temperature Range                            32°F to 122°F, 100% load (0°C to 50°C)
Storage Temperature Range                              -4°F to 158°F (­20° C to 70°C)
Operating Humidity Range                               30­90% RH (no condensation)
Storage Humidity Range                                 10­95% RH (no condensation)
Operating Altitude                                     Up to 6,500 feet (2,000 m)
Installation Category                                  II (IEC 1010-1)
Pollution Degree                                       2 (IEC 1010-1)
Regulatory Approvals
Safety                                                 CSA 22.2 No. 61010-1 and UL61010-1. Marked with c(UL) us, CE EN61010-1
EMC                                                    Complies with EN55022, Class A, FCC Part 15A for conducted emissions
                                                       Complies with EN55022, Class A, FCC Part 15A for radiated emissions
                                                       Complies with EN61000-4 series of standards for immunity
Mechanical Specifications
XG 1700 Watt (W×H×D)                                   16.8 x 1.7 x 19.0 inch (429 x 43.6 x 483 mm without rack mount ears)
Weight                                                 22 lb (10 kg)
Cooling                                                Forced air cooling by internal fans
* Typical
1. Time for the output voltage to recover within 0.05% at its rated output for a load change 10-90% of rated ouput current. Output set point 10-100%

Note: All specifications are subject to change.


Model Number Description




                                                               XG 33                                 50 (XXX)

                                      Series                                                                                                    Options
                                                  Voltage                                                                  Current

XG Options
MEA                                                    LXI Class C ETHERNET
MGA                                                    GPIB, IEEE 488.2
XG Options and Accessories
RM - XG1                                               Rackmount Angle Brackets




                             858.458.0223                                                              sales@ProgrammablePower.com