Medically Approved Plug & Play Power Supply 400W-1200W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
vite
Medical
Medically Approved patents pending
Ultra-high efficiency 1U size
The Xvite family of medically approved power supplies provides up to an
incredible 1200W in an extremely compact 1U x 260 x 127mm package. Providing
PLUG & PLAY POWER up to 12 isolated DC outputs, the Xvite family employs innovative plug & play
architecture allowing users to instantly configure a custom power solution in
next generation power source less than 5 minutes!
FEATURES The Xvite family consists of 4 powerPacs ranging in power levels from 400W to 1200W
and 7 powerMod DC output modules. Simply select the appropriate powerPac and up to
· UL2601-1 and EN60601-1 approved 6 powerMods from the tables below to complete your custom power supply.
· Less than 300µA leakage current
· 4000VAC isolation The Xvite family boasts an industry leading power density of 15W/in3 and ultra-high
· 1340W available (See XVE datasheet) efficiencies (up to 90%). The significant system space savings and reduced heat
dissipation radically simplify system design.
· Extra low profile: 1U height (40mm)
· Ultra high efficiency up to 90% All configurations carry full safety agency approvals including UL2601-1and EN60601-1
· Plug & Play Power and are CE marked. For alternative power interfaces contact support@excelsys.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allows fast custom configuration
- allow easy logistics
powerMods powerPacs
· Reduced system heat dissipation
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Few electrolytic capacitors (all long life)
· Visual LED indicators Xg1 1.5 2.5 3.6 50A 125W XVA 400W
Xvite
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W XVB 700W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W XVC 1000W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W XVD 1200W
Xg5 28.0 48.0 58.0 6A 288W
APPLICATIONS INCLUDE XVE 1340W
Xg7 5.0 24.0 28.0 5A 120W
· Clinical diagnostic equipment See XVE datasheet
Xg8 V1 5.0 24.0 28.0 3A 72W
· Medical lasers
V2 5.0 24.0 28.0 3A 72W
· Dialysis equipment
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Decription Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Medical
Power Rating XVA 400 W
XVB 700 W
XVC Derate linearly from 1000W at 100VAC to 850W at 85VAC 1000 W
XVD Derate linearly from 1200W at 120VAC to 850W at 85VAC 1200 W
Input Current XVA 85VAC in 400W out 7.5 A
XVB 85VAC in 700W out 9.5 A
XVC, XVD 85VAC in 850W out 11.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XVA 250V F8A HRC
XVB 250V F10A HRC
XVC, XVD 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. XCA,XCB,XCC / XCD 20 / 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1200W @ 24V 90 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Earth Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.5 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
2 Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 1.6% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Doc. 40039 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Medically Approved Plug & Play Power Supply 1340W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
vite
Medical
Medically Approved patents pending
Ultra-high efficiency 1U size
The XVE addition to the Xgen family of medically approved power supplies
provides up to 1340W (peak power 1450W) in the most compact package of 1U x
PLUG & PLAY POWER 268mm x 127mm. Boasting an industry leading 17W/in3 and 90% efficiency, the
XVE can provide up to 12 isolated DC outputs. The XVE employs innovative plug
next generation power source & play architecture allowing users to instantly configure a custom power solution
in less than 5 minutes!
FEATURES
Ultra high efficiencies and high power density are made possible through the
· UL60601-1 and EN60601-1 approved combination of low loss technologies and best field-proven techniques in planar
· Less than 300µA leakage current magnetics and surface mount electronics. The significant system space savings and
· 4000VAC isolation reduced heat dissipation radically simplify system design.
· 1450W peak power for 10sec
The XVE can be populated with up to 6 powerMods selected from the table of
· Extra low profile: 1U height (40mm)
powerMods shown below.
· Ultra high efficiency up to 90%
· Plug & Play Power All configurations carry full safety agency approvals including UL60601-1and EN60601-1
- allows fast custom configuration and are CE marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allow easy logistics
powerMods powerPacs
· Reduced system heat dissipation
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Few electrolytic capacitors (all long life)
· Visual LED indicators Xg1 1.5 2.5 3.6 50A 125W XVE 1340W
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W
Xg5 28.0 48.0 58.0 6A 288W
APPLICATIONS INCLUDE
Xg7 5.0 24.0 28.0 5A 120W
· Clinical diagnostic equipment
· Medical lasers Xg8 V1 5.0 24.0 28.0 3A 72W
V2 5.0 24.0 28.0 3A 72W
· Dialysis equipment
· For Standard applications see XCE
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 54.00 97.75
Efficiency %
90 122.00 92.00
89
23.50 SLOT F
88
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86 TOP VIEW SLOT D
80.00 19.00 127.00
85 SLOT C
J2
19.00
84
SLOT B
70 85 100 115 130 145 160 175 190 205 220 235 260
SLOT A
Line Voltage VAC 23.50
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
1340W Medically Approved Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Decription Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Medical
Power Rating XVE See Xgen Designers' Manual for derating versus input line voltage 1340(1450) W
Input Current XVE 85VAC in 1000W out 14.0 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XVE 250V F15A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 700 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. 230VAC/115VAC 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1340W @ 24V 90 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Earth Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 30mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
2 Storage Temperature -40 +85 °C
Derating See Designers Manual for full deratings versus temperature
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. 1450W peak for 10s; Duty cycle 8%. powerMod output power must not exceed normal ratings
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
XVE Rev 02 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim