Hier Klicken für das PDF Dokument!!!

A100ERU Series
Single & Dual Output, 1.5W
Ultra-Wide Input Range
DC/DC Converters
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                 Input
Key Features:                    Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
· 1.5W Output Power                                                                                                    24 VDC Input           9.0       24.0       36.0
                                 Input Voltage Range (See Note 1)                                                                                                                 VDC
· 4:1 Input Voltage Range                                                                                              48 VDC Input          36.0       48.0       72.0
· 1,500 VDC Isolation            Input Filter                                                                                     Capacitors
· -40ºC to +85ºC Temp Range      Short Circuit Input Power                                                                                             1,000                      mW
· Compact DIP Case               Output
· Single & Dual Outputs          Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
· 1.0 MH MTBF                    Output Voltage Accuracy                                                                                                ±1.0       ±3.0            %
· Industry Standard Pin-Out      Output Voltage Balance                                         Dual Output , Balanced Loads                            ±3.0                       %
· Low, Low Cost!                 Line Regulation                                                                  Vin = Min to Max                      ±0.2      ±0.75            %
                                 Load Regulation                                                             Iout = 10% to 100%                         ±0.5       ±2.0            %
                                 Noise (20 Hz - 300 kHz)                                                                  See Note 2                     50        100         mV P - P
                                 Ripple (DC - 20 MHz)                                                                                                               50         mV P - P
                                 Output Power Protection                                                                                     120                                   %
                                 Temperature Coefficient                                                                                                          ±0.03          %/ºC
                                 Output Short Circuit                                                                   Continuous (Autorecovery)
                                 General
                                 Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
                                 Isolation Voltage                                                                       60 Seconds         1,500                                 VDC
                                 Isolation Resistance                                                                        500 VDC        1,000                                 M
                                 Isolation Capacitance                                                                                                  100                        pF
                                 Switching Frequency                                                                                                               550            kHz
                                 Environmental
                                 Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
                                 Operating Temperature Range                                                                 Ambient          -40                  +85             ºC
                                 Storage Temperature Range                                                                                    -50                  +125            ºC
                                 Cooling                                                                                    Free Air Convection
                                 Humidity                                                                   RH, Non-condensing                           95                        %
                                 Physical
                                 Case Size (See Note 3)                                                                    1.25 x 0.80 x 0.37 Inches (31.8 x 20.3 x 9.5 mm)
                                 Case Material (See Note 3)                                                                          Non-Conductive Black Plastic (UL94V-0)
MicroPower Direct
                                 Weight                                                                                                                                   0.52 Oz (15g)
292 Page Street
Suite D                          Reliability Specifications
Stoughton, MA 02072              Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
USA
                                 MTBF                                                    MIL HDBK 217F, 25ºC, Gnd Benign                      1.0                              MHours
T: (781) 344-8226                Absolute Maximum Ratings
F: (781) 344-8481                Parameter                                                              Conditions                           Min.       Typ.      Max.           Units
E: sales@micropowerdirect.com
                                                                                                                       24 VDC Input          -0.7                  50.0
W: www.micropowerdirect.com      Input Voltage Surge (1 Sec)                                                                                                                      VDC
                                                                                                                       48 VDC Input          -0.7                 100.0
                                 Lead Temperature                                              1.5 mm From Case For 10 Sec                                         300             ºC
                                 Internal Power Dissipation                                                                All Models                             1,500           mW
                                                   Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

                                                                   www.micropowerdirect.com1 · D-85716 Unterschleißheim
                                                                         CompuMess Elektronik GmbH · Lise-Meitner-Str.
                                                                         Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                           info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                                                   CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                                   Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                                                               www.micropowerdirect.com
                                                                                                                   info@compumess.de · www.compumess.de · www.netzteile.de

                                               Input                                                      Output                              Fuse Rating
   Model                                                                                                                         Efficiency
                        Voltage (VDC)                       Current (mA)
                                                         Voltage Current  Current                                                             Slow-Blow
  Number                                                                                                                          (%, Typ)
                   Nominal   Range     Full-Load No-Load (VDC) (mA, Max) (mA, Min)                                                               (mA)
A101ERU              24     9.0 - 36.0     86      20       3.3     500     50.0                                                      73           200
A102ERU              24     9.0 - 36.0     83      20       5.0     300     30.0                                                      75           200
A103ERU              24     9.0 - 36.0     80      20       9.0     167     17.0                                                      78           200
A104ERU              24     9.0 - 36.0     78      20      12.0     125     12.0                                                      80           200
A105ERU              24     9.0 - 36.0     77      20      15.0     100     10.0                                                      81           200
A106ERU              24     9.0 - 36.0     85      20      ±5.0    ±150    ±15.0                                                      73           200
A107ERU              24     9.0 - 36.0     80      20     ±12.0     ±63     ±6.0                                                      78           200
A108ERU              24     9.0 - 36.0     79      20     ±15.0     ±50     ±5.0                                                      79           200
A111ERU              48    18.0 - 72.0     43      10       3.3     500     50.0                                                      72           150
A112ERU              48    18.0 - 72.0     42      10       5.0     300     30.0                                                      74           150
A113ERU              48    18.0 - 72.0     40      10       5.0     167     17.0                                                      77           150
A114ERU              48    18.0 - 72.0     39      10      12.0     125     12.0                                                      79           150
A115ERU              48    18.0 - 72.0     39      10      15.0     100     10.0                                                      80           150
A116ERU              48    18.0 - 72.0     43      10      ±5.0    ±150    ±15.0                                                      72           150
A117ERU              48    18.0 - 72.0     40      10     ±12.0     ±63     ±6.0                                                      77           150
A118ERU              48    18.0 - 72.0     40      10     ±15.0     ±50     ±5.0                                                      78           150

                                                                                                                  Derating Curve
        For models with a metal case, add an
      "M" to the model number (ie: A115ERUM)
Notes:
1. Exceeding the input range by a significant margin may damage the units. For 24V input the
   input voltage should not exceed 40V; for 48V models it should not exceed 80V.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor
   be placed from the +Vout pin to the -Vout pin for single output units and from each output to common
   for dual output units.
3. The optional metal package is nickel plated steel. Dimensions are 1.25 x 0.80 x 0.39 Inches (31.8 x
   20.3 x 10.0 mm).
4. These units should not be operated with a load under the specified minimum. Operation at
   no-load will increase ripple significantly and may cause damage to the unit.
5. These converters are specified for operation without external components. However, in some
   applications the addition of input/output capacitors will enhance stability and reduce output
   ripple. Recommended capacitor values are:

                                                      Output Capacitor
      Vin           Input              Vout
    (VDC)         Capacitor            (VDC)      0 to +70ºC        -40 to +85ºC            Mechanical Dimensions
                                                 (Electrolytic)       (Tantalum)
              Sing   10 µF              3.3          100 µF              47 µF
      24
              Dual 10 ~ 47 µF            5           100 µF              47 µF
              Sing   10 µF              12           100 µF              47 µF
      48
              Dual 10 ~ 47 µF           15           100 µF              47 µF
   For applications requiring very low output noise levels, a simple LC filter should
   be effective.
6. It is recommended that a fuse be used on the input of a power supply for
   protection. See the Model Selection table above for the correct rating.




                Pin Connections
                     Pin           Single           Dual
                     2, 3           -Vin             -Vin
                       9          No Pin         Common
                      10             NC              NC
                      11             NC             -Vout
                      14           +Vout           +Vout
                      15             NC              NC
                      16           -Vout         Common
                   22, 23           +Vin            +Vin
                           NC: No Connection
                                                                                                                                                  Mechanical Notes:

                                   MicroPower Direct                                                                                              · All dimensions are typical in inches (mm)
                                                                                                                                                  · Tolerance x.xx = ±0.01 (±0.25)


                                   We Power Your Success CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                          - For Less!
                                  292 Page Street Ste D Stoughton, MA 02072                         ·     TEL: (781) 344-8226 ·
                                                                                                                                   0 · (781) 344-8481
                                                                                                          Telefon (089) 32 15 01 -FAX: Telefax (089) 32·15E-Mail: sales@micropowerdirect.com
                                                                                                                                                          01 - 11
                                                                                                          info@compumess.de · www.compumess.de · www.netzteile.de