A200ERW Series
Very Low Cost, 2W
Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
Parameter Conditions Min. Typ. Max. Units
· 2W Output Power
5 VDC Input 4.5 5.0 9.0
· 2:1 Input Voltage Range 12 VDC Input 9.0 12.0 18.0
Input Voltage Range (See Note 1) VDC
· 1,500 VDC Isolation 24 VDC Input 18.0 24.0 36.0
· Compact DIP Case 48 VDC Input 36.0 48.0 72.0
· Single & Dual Outputs Input Filter Capacitors
Reverse Polarity Input Current 1.0 A
· Efficiency to 85%
Short Circuit Input Power 1,000 mW
· 1.0 MH MTBF Output
· Industry Standard Pin-Out Parameter Conditions Min. Typ. Max. Units
· Very LOW COST! Output Voltage Accuracy ±1.0 ±3.0 %
Output Voltage Balance Dual Output , Balanced Loads ±0.5 ±2.0 %
Line Regulation Vin = Min to Max ±0.2 ±0.5 %
Load Regulation Iout = 10% to 100% ±0.5 ±0.75 %
Ripple (20 Hz - 300 kHz) See Note 2 30 60 mV P - P
Noise (DC - 20 MHz) 80 150 mV P - P
Output Power Protection 120 %
Temperature Coefficient ±0.01 ±0.02 %/șC
Output Short Circuit Continuous (Autorecovery)
General
RoHS Compliant Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 1,500 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz, 1V 30 pF
Switching Frequency 80 200 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient
-40 +25 +85 șC
Storage Temperature Range -55 +125 șC
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
MicroPower Direct Physical
292 Page Street
Suite D Case Size 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Stoughton, MA 02072 Case Material Non-Conductive Black Plastic (UL94-V0)
USA Weight 0.42 Oz (12g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481 Parameter Conditions Min. Typ. Max. Units
E: sales@micropowerdirect.com MTBF MIL HDBK 217F, 25șC, Gnd Benign 1.0 MHours
W: www.micropowerdirect.com Absolute Maximum Ratings
Parameter Conditions Min. Typ. Max. Units
5 VDC Input -0.7 11.0
12 VDC Input -0.7 22.0
Input Voltage Surge (1 Sec) VDC
24 VDC Input -0.7 40.0
48 VDC Input -0.7 80.0
Lead Temperature 1.5 mm From Case For 10 Sec 300 șC
Internal Power Dissipation All Models 2,000 mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output Fuse Rating
Model Efficiency
Voltage (VDC) Current (mA) Voltage Current Current Slow-Blow
Number (%, Typ)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (mA)
A201ERW 5 4.5 - 9.0 597 35 5.0 400 40 67 1,000
A202ERW 5 4.5 - 9.0 580 35 9.0 220 22 69 1,000
A203ERW 5 4.5 - 9.0 555 35 12.0 165 16 72 1,000
A204ERW 5 4.5 - 9.0 533 35 15.0 133 14 75 1,000
A205ERW 5 4.5 - 9.0 597 35 ±5.0 ±200 ±20 67 1,000
A206ERW 5 4.5 - 9.0 563 35 ±9.0 ±111 ±11 71 1,000
A207ERW 5 4.5 - 9.0 555 35 ±12.0 ±83 ±8 72 1,000
A208ERW 5 4.5 - 9.0 548 35 ±15.0 ±67 ±7 73 1,000
A211ERW 12 9.0 - 18.0 277 15 5.0 400 40 60 500
A212ERW 12 9.0 - 18.0 222 15 9.0 220 22 75 500
A213ERW 12 9.0 - 18.0 216 15 12.0 165 16 77 500
A214ERW 12 9.0 - 18.0 208 15 15.0 133 14 80 500
A215ERW 12 9.0 - 18.0 222 15 ±5.0 ±200 ±20 75 500
A216ERW 12 9.0 - 18.0 219 15 ±9.0 ±111 ±11 76 500
A217ERW 12 9.0 - 18.0 214 15 ±12.0 ±83 ±8 78 500
A218ERW 12 9.0 - 18.0 214 15 ±15.0 ±67 ±7 78 500
A221ERW 24 18.0 - 36.0 107 8 5.0 400 40 78 250
A222ERW 24 18.0 - 36.0 104 8 9.0 220 22 80 250
A223ERW 24 18.0 - 36.0 100 8 12.0 165 16 83 250
A224ERW 24 18.0 - 36.0 98 8 15.0 133 14 85 250
A225ERW 24 18.0 - 36.0 109 8 ±5.0 ±200 ±20 76 250
A226ERW 24 18.0 - 36.0 107 8 ±9.0 ±111 ±11 78 250
A227ERW 24 18.0 - 36.0 105 8 ±12.0 ±83 ±8 79 250
A228ERW 24 18.0 - 36.0 107 8 ±15.0 ±67 ±7 78 250
A231ERW 48 36.0 - 72.0 55 4 5.0 400 40 76 135
A232ERW 48 36.0 - 72.0 51 4 9.0 220 22 81 135
A233ERW 48 36.0 - 72.0 51 4 12.0 165 16 82 135
A234ERW 48 36.0 - 72.0 50 4 15.0 133 14 83 135
A235ERW 48 36.0 - 72.0 56 4 ±5.0 ±200 ±20 75 135
A236ERW 48 36.0 - 72.0 53 4 ±9.0 ±111 ±11 78 135
A237ERW 48 36.0 - 72.0 52 4 ±12.0 ±83 ±8 80 135
A238ERW 48 36.0 - 72.0 52 4 ±15.0 ±67 ±7 80 135
Notes:
1. Exceeding the input range by a significant margin may damage the units. For 5V input models the input voltage
should not exceed 11V, for 12V input models 22V, for 24V input units 40V, and for 48V models 80V.
Pin Connections
2. When measuring output ripple, it is recommended that an external 0.33 ”F ceramic capacitor be placed from the Pin Single Dual Pin Single Dual
+Vout pin to the -Vout pin for single output units and from each output to common for dual output units.
3. These units should not be operated with a load under the specified minimum. Operation at no-load will increase
2 -Vin -Vin 14 +Vout +Vout
ripple significantly and may cause damage to the unit. 3 NC -Vout 15 NC NC
4. These converters are specified for operation without external components. However, in some applications the 9 NC Common 16 -Vout Common
addition of input/output capacitors will enhance stability and reduce output ripple. Recommended values are:
10 NC NC 22 +Vin +Vin
Output Capacitor
Input 11 NC -Vout 23 +Vin +Vin
Vin Vout 0șC to +70șC -40șC to +85șC
Capacitor NC: No Connection
(Electrolytic) (Tantalum)
5 VDC 100 ”F 5 VDC 100 ”F 47 ”F
12 VDC 100 ”F 9 VDC 100 ”F 47 ”F Mechanical Dimensions
24 VDC 10 ”F 12 VDC 100 ”F 47 ”F
48 VDC 10 ”F 12 VDC 100 ”F 47 ”F
In applications requiring very low output noise levels, a simple LC filter should be effective.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Derating Curve
MicroPower Direct
Mechanical N
Notes:
· All dimensions are typical in inches (mm)
dimension
x.x