                                                             ABD100 Test Suite Software




Applications
  · Pre-compliance testing for Airbus A380
  · Aircraft component design and development
  · Avionics power testing
  · Subsystem qualification                                               SmartWaveTM Control Suite
The ABD100 Test Suite software, used in conjunction with a
SmartWaveTM ac/dc power source, provides a simple method to
test components and subsystems according to the complex power
requirements of the Airbus A380 aircraft. Utilizing the SmartWave'sTM
arbitrary waveform and powerful sequencing capability, the Test Suite
allows the user to select from a vast library of ABD100 compliant
tests to drive the device-under-test. In addition, the standard library
may be modified to develop custom tests for performing margin
analysis during design and development.

ABD 100 Test Specification
The ABD100 document details up to 10 different types of tests
required for equipment powered by any of five types of supply sources
available (Table A-E) on the A380. The SmartWaveTM/ABD100 Test
Suite combination provides the power waveforms for all supply source
types, addressing most of the specific tests (see compliance matrix).     SWCS Utility Software, the basis for the ABD100 Test Suite,
Developed separately, the library of tests provided by the Test Suite     allows easy Windows-based setup of the SmartWaveTM for
would take thousands of hours of programming time, effectively            settings unique to the device-under-test, viewing and editing
saving months of development time for the user.                           of waveforms plus many other features to simplify use of the ac
                                                                          source.




      CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
            Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
ABD100 Test Suite Software
SmartWaveTM Power Source                                                                 Minimum System Requirements
The SmartWaveTM provides the hardware platform for the Test                                    SmartWaveTM, ECDI rev. 5.05 or higher, DWSB rev. 2.4
Suite. This combination ac and dc supply source is available in                                PII 500MHz or higher
versions from 1 to 3 phases, with the ability to source from 13 to                             128MB RAM (256MB Recommended)
52A per phase, or 13 to 156A dc or single phase ac. The powerful                               500MB available on hard disk
                                                                                               CD-ROM
sequencing capability allows the source to generate complex
                                                                                               Windows XP/2000
waveform sequences, with precise timing, to meet the demanding                                 Internet Explorer 5.0 or higher
requirements of the ABD100 standard. For complete information                                  National Instruments GPIB or GPIB-PCMCIA card
and full specifications on the SmartWaveTM ac/dc source see                                    GPIB Interface cable
Elgar's full product catalog, or go to www.elgar.com
                                                                                         ABD100 Compliance Matrix
Test Suite Software                                                                          Test #      Table A Table B Table C Table D Table E
Running under Windows XP/2000, the Test Suite provides a simple                               Test 1                                       
method for the user to select and execute either single tests or a                            Test 2                                       
sequence of tests compliant with the ABD100 standard. From the                                Test 3                                       
SmartWaveTM Control Suite, a general-purpose software utility                                 Test 4                                       --
                                                                                              Test 5        --      --     --       --     
for programming the SmartWaveTM, the user selects the required                                Test 6                                       P
table, and the Test Suite automatically lists the sequences                                   Test 7                                       
available for that table. Once selected the tests may be looped,                              Test 8                                P
single stepped, or run in a series. During execution, the screen is                           Test 9                       
updated with status of the test and total time remaining.                                    Test 10                       
                                                                                               P   These are compliant with ABD100 with the limitation of
SPECIFICATIONS                                                                                     ripple frequency to max of 1kHz.


                                                                                         Power Source Compatibility
                                                                                               Output Voltage: AC (rms) or DC - 0-156V, 0-312V
                                                                                               Output Frequency: DC, 40Hz to 5kHz

                                                                                                                             Max ac           Max dc or
                                                                                           SmartWaveTM
                                                                                                             Phases         Current per      single phase
                                                                                             Model
                                                                                                                              phase*         ac Current**
                                                                                            SW1750A             1              13A                13A
                                                                                            SW3500A           1 or 2        13A/phase             26A
                                                                                            SW5250A            1, 3         13A/phase             39A
                                                                                            SW10500            1, 3         26A/phase             78A
                                                                                            SW15750            1, 3         39A/phase            127A
                                                                                            SW21000            1, 3         52A/phase            156A
                                                                                               * Maximum current is given for 0-156V output range,
                                                                                                  divide values in half for 0-312V range.
                                                                                               ** All phases in parallel.

                                                                                         Ordering Information
                                                                                         ABD100TSS-A       Table A tests only (115VAC/400Hz)
     The Test Suite ­ Test Selector allows the user to easily build
                                                                                         ABD100TSS-B       Table B tests only (26VAC/400Hz)
     a test sequence from the library of ABD100 compliant tests.
                                                                                         ABD100TSS-C       Table C tests only (115VAC/variable freq)
     Detailed descriptions of each test are provided for convenience
                                                                                         ABD100TSS-DE      Table D & E tests only (Conventional and NBPT dc)
     as well as the capability of saving a test sequence for future
     recall.
                                                                                   To order combinations of tests, or the entire test set, add the Table
                                                                                   designator (A, B, C, DE) on to the end of the part number.
                                                                                   (e.g. to get both Table A & B, order ABD100TSS-AB; or entire test set,
                                                                                   ABD100TSS-ABCDE)


                                                                       Once the test sequences are selected, the Test Executor allows
                                                                       the user to run the tests with the press of a button. Test status
                                                                       is displayed in three progress windows with total test time,
                                                                       individual or sequence time and progress within a test, or
                                                                       segment time.




     P O W E R              E V O L V E D
         CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim