Enclosed Switching Power Supplies
100 Watt Single and Triple Outputs
115/230 VAC Sw. Sel. Input A-100F
High Efficiency Series
Regulated Outputs
1500V Isolation
Built in EMI Filter
Single Unit measures 3.92"W x 7.96"L x 1.52"H
Triple Unit measures 4.4"W x 7.96"L x 2"H
MODEL SELECTIONS
Output Output Output Price
Model Number Voltage Amps (MAX) Min. Load 1 25
SINGLE OUTPUT
AS-100F-5 5 VDC 20 0 $69 $64
AS-100F-7.5 7.5 VDC 13.5 0 $69 $64
AS-100F-12 12 VDC 8.5 0 $69 $64
AS-100F-15 15 VDC 6.7 0 $69 $64
AS-100F-24 24 VDC 4.5 0 $69 $64
AS-100F-48 48 VDC 2.2 0 $69 $64
Contact
Factory
for
Output Output Output High Volume
Voltage Amps (MAX) Min. Load Price Pricing
Model Number CH1/2/3 CH1/2/3 CH1/2/3 1 25
TRIPLE OUTPUT
AT-100-C +5/+15/-15 10/2.5/1 2/0.2/0.1 $73 $68
AT-100-D +5/+12/+24 6/2/2 2/0.1/0.2 $73 $68
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Enclosed Switching Power Supplies
100 Watt Single and Triple Outputs
All specifications are typical at nominal input, full load, and 25DegC
unless otherwise noted
INPUT SPECIFICATIONS GENERAL SPECIFICATIONS
Input Voltage Range 88-132 / 176-264 VAC Input-Out Isolation I/P-O/P:3000VAC
Switch Selected I/P-Ground: 1500VAC
Frequency Range 47-440 Hz Efficiency 79%, typ
Inrush Current, typ: 30A @ 115VAC Input * Switching Frequency
60A @ 230VAC Input * Singles/Triples 83kHz/25kHz, typ
Safety AS-100F ONLY
OUTPUT SPECIFICATIONS UL1012 UL File # E127738/E183223
EN60950 TUV File # R9152411
Voltage and Current See Selection Chart
Load Regulation (Singles) 5V:+/-1%, Others:+/-0.5% ENVIRONMENTAL SPECIFICATIONS
(20% to FL) (Triples) CH1:+/-1%, CH2/CH3:+/-5%
Line Regulation (Singles) +/- 0.5%, typ Oper. Temperature -10 to +60 DegC(see derate)
(Triples) CH1:+/-0.5%, CH2/CH3:+/-1% Storage Temperature -20 to +85 DegC *
Voltage Tolerance (Singles) 5V:+/-2%, Others:+/-1%, typ Relative Humidity 20 to + 90%, non-cond *
(Triples) CH1:+/-2%, CH2/CH3:+/-6% EMC CISPR22 (EN55022)
DC Voltage Adjust (typ) +10,-5% of FS (CH1) IEC801-2,3,4
Temperature Coefficient +/-0.03%/DegC MTBF Single/Triple 110Khrs/41Khrs
Ripple/Noise 120mV Pk-Pk, typ Mil Std 217, 25C
Over Voltage Protection 115-135%, single/dual-CH1 *
Overload Protection (Singles) 105-150% Shutdown, Auto Rec PHYSICAL SPECIFICATIONS
(Triples) 105-150% Shutdown, AC on/off
Setup, Rise, Hold Up Time, typ 1S, 30mS, 15mS, singles Size
200mS, 50mS, 16mS, triples AS-100F 3.92" x 7.96" x 1.52"
AT-100 4.4" x 7.96" x 2"
Construction Enclosed
Weight AS-100F 23.21 oz, (650g)
AT-100 29.64 oz, (830g)
OUTPUT DERATING CURVES
Astrodyne products are not authorized or warranteed for
use as critical components in life support systems,
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim in hazardous environments, nuclear
equipment used
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
controls systems, or other mission-critical applications.
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions other
than the standard operating conditions is neither warranteed nor implied.
Enclosed Switching Power Supplies
100 Watt Single and Triple Outputs
All specifications are typical at nominal input, full load, and 25DegC
unless otherwise noted
MECHANICAL DIMENSIONS
Pin # Single AT-100-C AT-100-D
1 AC Line AC Line AC Line
2 AC Neut. AC Neut. AC Neut.
3 FG FG FG
4 - Vout + V2out + V3out
5 - Vout + V3out Common
6 + Vout Common + V2out
7 + Vout Common Common
8 No Term. +V1out +V1out
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions other
than the standard operating conditions is neither warranteed nor implied.