Hier Klicken für das PDF Dokument!!!

C4000RW Series
Wide 2:1Input 40W
Single, Dual & Triple Output
DC/DC Converters
          Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                 Input
                                 Parameter                                                               Conditions                Min.                 Typ.       Max.          Units
                                                                                                                  12 VDC Input       9.0                12.0       18.0
Key Features:                    Input Voltage Range                                                              24 VDC Input 18.0                     24.0       36.0           VDC
· 40W Output Power                                                                                                48 VDC Input 36.0                     48.0       75.0
                                 Input Filter                                                                               (Pi) Filter
· 2:1 Input Voltage Range
                                 Output
· 1,600 VDC Isolation            Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
· 12, 24, & 48V Input            Output Voltage Accuracy, See Note 1                                                                                    ±2.0                      %
                                 Line Regulation, Single, Dual Output                                      For Vin Min to Max                           ±0.5                      %
· Single, Dual, Triple Output                                                                                           Vout 1                          ±1.0
                                 Line Regulation, Triple Output                                                                                                                    %
· Remote ON/OFF                                                                                               Vout 2 & Vout 3                           ±5.0
                                 Load Regulation, Single Output                                          Iout = 10% to 100%                             ±1.0                       %
· >550 kHour MTBF                Load Regulation, Dual Output                                            Iout = 10% to 100%                             ±2.0                       %
· Industry Standard Pin-Out      Load Regulation, Triple Output
                                                                                                 Iout = 10% to 100%, Vout 1                             ±3.0
                                                                                                                                                                                   %
                                                                                        Iout = 10% to 100%, Vout 2 & Vout 3                             ±5.0
                                                                                                        Single Output Models                          ±1.0       %
                                 Ripple, See Note 2
                                                                                                   Dual/Triple Output Models               0.2% Vout + 20 mV P - P Max.
                                                                                                            5V Output Models                          100        mV
                                 Noise, See Note 2                                             12V, 15V &24V Output Models                            ±1.0       %
                                                                                                   Dual/Triple Output Models               0.5% Vout + 50 mV P - P Max.
                                 Output Power Protection, See Note 3                                                                   120                       %
                                 Over Voltage Protection, See Note 3                                                                   112            165        %
                                 Temperature Coefficient                                                                                      ±0.02            %/°C
                                 Output Short Circuit                                                                   Continuous (Autorecovery)
                                 General
                                 Parameter                                                               Conditions                         Min.        Typ.       Max.          Units
                                 Isolation Voltage                                                                    60 Seconds            1,600                                VDC
                                 Isolation Resistance                                                                    500 VDC            1,000                                 M
                                 Isolation Capacitance                                                                100 kHz, 1V                      1,000                      pF
                                                                                                                5V Output Models                        250
                                 Switching Frequency                                                           12V Output Models                        200                       kHz
                                                                                                                 All Other Models                       400
                                 Remote On/Off, See Note 5
                                 Parameter                                                               Conditions                          Min.       Typ.Max.      Units
                                 Supply On                                                                                                   5.0            15.0       VDC
                                 Supply Off                                                                                                  -1.0           +1.0       VDC
                                 Input Current (On)                                                                                                          -1         mA
                                 Input Current (Off)                                                                                                          1         mA
                                 Control Common                                                                                             Referenced to Negative Input (pin 2)
                                 Environmental
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                 Operating Temperature Range                                                                  Ambient        -25                   +70            °C
                                 Operating Temperature Range                                                                    Case                               +100           °C
                                 Storage Temperature Range                                                                         -55                             +105           °C
MicroPower Direct                Cooling                                                                               See Derating Curve
292 Page Street                  Humidity                                                                    RH, Non-condensing                                      95            %
Suite D                          Physical
Stoughton, MA 02072              Case Size                                                                                 2.0 x 2.0 x 0.45 Inches (50.8 x 50.8 x 11.4 mm)
USA                              Case Material                                                                          Nickel Coated Copper with Non-Conductive Base
                                 Weight                                                                                                                       2.47 Oz (70g)
T: (781) 344-8226                Reliability Specifications
F: (781) 344-8481                Parameter                                                        Conditions                                 Min.       Typ.       Max.          Units
E: sales@micropowerdirect.com    MTBF                                                    MIL HDBK 217F, 25°C, Gnd Benign                     550                                kHours
W: www.micropowerdirect.com      Absolute Maximum Ratings
                                 Parameter                                                            Conditions                             Min.       Typ.      Max.           Units
                                                                                                               12 VDC Input                  -0.7                  25.0
                                 Input Voltage Surge (0.1 Sec)                                                 24 VDC Input                  -0.7                  50.0           VDC
                                                                                                               48 VDC Input                  -0.7                 100.0
                                 Lead Temperature                                               1.5 mm From Case For 10 Sec                                        260             °C
                                                    Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                   www.micropowerdirect.com
                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                            info@compumess.de · www.compumess.de · www.netzteile.de
                                                                                                                                      CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                                                      Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide                                                                                                                 www.micropowerdirect.com
                                                                                                                                      info@compumess.de · www.compumess.de · www.netzteile.de

                                           Input                  Output 1                                         Output 2                  Max.
                                                                                                                                             Output 3                       Fuse
    Model                                                                                                                                   Output Efficiency Capacitive   Rating
   Number           Voltage (VDC)               Current (mA)  Voltage Current                               Voltage Current Voltage Current Power                Load
                                                                                                                                                     (Typ %)
                                                                                                                                                               (µF Max)
                                                                                                                                                                         Slow-Blow
                    Nom. Range              Full-Load No-Load (VDC) (A, Max)                                  (VDC)        (A, Max)       (VDC)    (A, Max)    (W)                                               (mA)
 C4001RW             12   9 - 18              3,922      120      5.0    8.00                                                                                 40.0           85             13,600              8,500
 C4002RW             12   9 - 18              3,922      120    12.0     3.33                                                                                 40.0           85              1,800              8,500
 C4003RW             12   9 - 18              3,922      120    15.0     2.66                                                                                 40.0           85              1,200              8,500
 C4004RW             12   9 - 18              3,922      120    24.0     1.66                                                                                 40.0           85               330               8,500
 C4005RW             12   9 - 18              3,557      120    +5.0   +3.50                                   -5.0          -3.50                            35.0           82             ±1,000              8,500
 C4006RW             12   9 - 18              3,922      120   +12.0   +1.66                                 -12.00          -1.66                            40.0           85              ±150               8,500
 C4007RW             12   9 - 18              3,922      120   +15.0   +1.32                                 -15.00          -1.32                            40.0           85               ±82               8,500
 C4008RW             12   9 - 18              3,922      120      5.0    5.00                                 +12.0          +0.60        -12.0      -0.60    40.0           85          1,000/ ±120            8,500
 C4009RW             12   9 - 18              3,922      120      5.0    5.00                                 +15.0          +0.50        -15.0      -0.50    40.0           85           1,800/ ±82            8,500
 C4011RW             24 18 - 36               1,915       85      5.0    8.00                                                                                 40.0           87             13,600              4,500
 C4012RW             24 18 - 36               1,938       85    12.0     3.33                                                                                 40.0           86              1,800              4,500
 C4013RW             24 18 - 36               1,938       85    15.0     2.66                                                                                 40.0           86              1,200              4,500
 C4014RW             24 18 - 36               1,938       85    24.0     1.66                                                                                 40.0           86               330               4,500
 C4015RW             24 18 - 36               1,757       85    +5.0   +3.50                                   -5.0          -3.50                            35.0           83             ±1,000              4,500
 C4016RW             24 18 - 36               1,938       85   +12.0   +1.66                                 -12.00          -1.66                            40.0           86              ±150               4,500
 C4017RW             24 18 - 36               1,938       85   +15.0   +1.32                                 -15.00          -1.32                            40.0           86               ±82               4,500
 C4018RW             24 18 - 36               1,938       85      5.0    5.00                                 +12.0          +0.60        -12.0      -0.60    40.0           86          1,000/ ±120            4,500
 C4019RW             24 18 - 36               1,938       85      5.0    5.00                                 +15.0          +0.50        -15.0      -0.50    40.0           86           1,800/ ±82            4,500
 C4021RW             48 36 - 75                947        50      5.0    8.00                                                                                 40.0           88             13,600              2,500
 C4022RW             48 36 - 75                957        50    12.0     3.33                                                                                 40.0           87              1,800              2,500
 C4023RW             48 36 - 75                957        50    15.0     2.66                                                                                 40.0           87              1,200              2,500
 C4024RW             48 36 - 75                957        50    24.0     1.66                                                                                 40.0           87               330               2,500
 C4025RW             48 36 - 75                868        50    +5.0   +3.50                                   -5.0          -3.50                            35.0           84             ±1,000              2,500
 C4026RW             48 36 - 75                957        50   +12.0   +1.66                                 -12.00          -1.66                            40.0           87              ±150               2,500
 C4027RW             48 36 - 75                957        50   +15.0   +1.32                                 -15.00          -1.32                            40.0           87               ±82               2,500
 C4028RW             48 36 - 75                957        50      5.0    5.00                                 +12.0          +0.60        -12.0      -0.60    40.0           87          1,000/ ±120            2,500
 C4029RW             48 36 - 75                957        50      5.0    5.00                                 +15.0          +0.50        -15.0      -0.50    40.0           87           1,800/ ±82            2,500
Notes:
1. For triple output models, the voltage accuracy of the auxiliary outputs is ±5%.                                                     Derating Curve
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic in parallel with a 10 µF capacitor be placed
   from the +Vout pin to the -Vout pin.
3. The unit will recover automatically when the fault condition is removed.
4. Over voltage protection is provided by a zener diode clamp.
5. If the on/off pin (Pin 4) is left open, the unit operates.
6. No load operation will not damage these units, but they may not meet all spec's.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.

Mechanical Dimensions




                                                                                                                                                                     External Trim
                                                                                                              Pin Connections
                                                                                                               Pin       Single          Dual       Triple
                                                                                                                 1    +Vin    +Vin    +Vin
                                                                                                                 2    -Vin    -Vin    -Vin
                                                                                                                 4   On/Off  On/Off  On/Off
                                                                                                                 5    NC     Vout 1  Vout 2
                                                                                                                 6   +Vout Common Vout 1
                                                                                                                 7   -Vout   Vout 2 Common
                                                                                                                 8    Trim    Trim   Vout 3
                                                                                                                NC = No Connection
                                                                                                                                                                     A simple external circuit may be used to adjust
                                                                                                                                                                     the converter output. To adjust the output DOWN,
                                                                                                           Mechanical Notes:                                         connect a 5%, 3W resistor between the plus output
                                                                                                           · All dimensions are typical in inches (mm)               pin and the Vout trim pin. To adjust the output UP,
                                                                                                           · Tolerance x.xx = ±0.01 (±0.25)                          connect a 5%, 3W resistor between the minus
                                                                                                                                                                     output pin and the Vout trim pin.
                                                                                                                                                                     For UP/Down trimming capability, connect a 10 kW
                                       MicroPower Direct                                                                                                             potentiometer between the plus and minus outputs
                                                                                                                                                                     with the wiper arm connected to the Vout trim pin.
                                                                                                                                                                     The range for the external trim is about ±10%.