C4000RW Series
Wide 2:1Input 40W
Single, Dual & Triple Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Conditions Min. Typ. Max. Units
12 VDC Input 9.0 12.0 18.0
Key Features: Input Voltage Range 24 VDC Input 18.0 24.0 36.0 VDC
· 40W Output Power 48 VDC Input 36.0 48.0 75.0
Input Filter (Pi) Filter
· 2:1 Input Voltage Range
Output
· 1,600 VDC Isolation Parameter Conditions Min. Typ. Max. Units
· 12, 24, & 48V Input Output Voltage Accuracy, See Note 1 ±2.0 %
Line Regulation, Single, Dual Output For Vin Min to Max ±0.5 %
· Single, Dual, Triple Output Vout 1 ±1.0
Line Regulation, Triple Output %
· Remote ON/OFF Vout 2 & Vout 3 ±5.0
Load Regulation, Single Output Iout = 10% to 100% ±1.0 %
· >550 kHour MTBF Load Regulation, Dual Output Iout = 10% to 100% ±2.0 %
· Industry Standard Pin-Out Load Regulation, Triple Output
Iout = 10% to 100%, Vout 1 ±3.0
%
Iout = 10% to 100%, Vout 2 & Vout 3 ±5.0
Single Output Models ±1.0 %
Ripple, See Note 2
Dual/Triple Output Models 0.2% Vout + 20 mV P - P Max.
5V Output Models 100 mV
Noise, See Note 2 12V, 15V &24V Output Models ±1.0 %
Dual/Triple Output Models 0.5% Vout + 50 mV P - P Max.
Output Power Protection, See Note 3 120 %
Over Voltage Protection, See Note 3 112 165 %
Temperature Coefficient ±0.02 %/°C
Output Short Circuit Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 1,600 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz, 1V 1,000 pF
5V Output Models 250
Switching Frequency 12V Output Models 200 kHz
All Other Models 400
Remote On/Off, See Note 5
Parameter Conditions Min. Typ.Max. Units
Supply On 5.0 15.0 VDC
Supply Off -1.0 +1.0 VDC
Input Current (On) -1 mA
Input Current (Off) 1 mA
Control Common Referenced to Negative Input (pin 2)
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -25 +70 °C
Operating Temperature Range Case +100 °C
Storage Temperature Range -55 +105 °C
MicroPower Direct Cooling See Derating Curve
292 Page Street Humidity RH, Non-condensing 95 %
Suite D Physical
Stoughton, MA 02072 Case Size 2.0 x 2.0 x 0.45 Inches (50.8 x 50.8 x 11.4 mm)
USA Case Material Nickel Coated Copper with Non-Conductive Base
Weight 2.47 Oz (70g)
T: (781) 344-8226 Reliability Specifications
F: (781) 344-8481 Parameter Conditions Min. Typ. Max. Units
E: sales@micropowerdirect.com MTBF MIL HDBK 217F, 25°C, Gnd Benign 550 kHours
W: www.micropowerdirect.com Absolute Maximum Ratings
Parameter Conditions Min. Typ. Max. Units
12 VDC Input -0.7 25.0
Input Voltage Surge (0.1 Sec) 24 VDC Input -0.7 50.0 VDC
48 VDC Input -0.7 100.0
Lead Temperature 1.5 mm From Case For 10 Sec 260 °C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
www.micropowerdirect.com
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output 1 Output 2 Max.
Output 3 Fuse
Model Output Efficiency Capacitive Rating
Number Voltage (VDC) Current (mA) Voltage Current Voltage Current Voltage Current Power Load
(Typ %)
(µF Max)
Slow-Blow
Nom. Range Full-Load No-Load (VDC) (A, Max) (VDC) (A, Max) (VDC) (A, Max) (W) (mA)
C4001RW 12 9 - 18 3,922 120 5.0 8.00 40.0 85 13,600 8,500
C4002RW 12 9 - 18 3,922 120 12.0 3.33 40.0 85 1,800 8,500
C4003RW 12 9 - 18 3,922 120 15.0 2.66 40.0 85 1,200 8,500
C4004RW 12 9 - 18 3,922 120 24.0 1.66 40.0 85 330 8,500
C4005RW 12 9 - 18 3,557 120 +5.0 +3.50 -5.0 -3.50 35.0 82 ±1,000 8,500
C4006RW 12 9 - 18 3,922 120 +12.0 +1.66 -12.00 -1.66 40.0 85 ±150 8,500
C4007RW 12 9 - 18 3,922 120 +15.0 +1.32 -15.00 -1.32 40.0 85 ±82 8,500
C4008RW 12 9 - 18 3,922 120 5.0 5.00 +12.0 +0.60 -12.0 -0.60 40.0 85 1,000/ ±120 8,500
C4009RW 12 9 - 18 3,922 120 5.0 5.00 +15.0 +0.50 -15.0 -0.50 40.0 85 1,800/ ±82 8,500
C4011RW 24 18 - 36 1,915 85 5.0 8.00 40.0 87 13,600 4,500
C4012RW 24 18 - 36 1,938 85 12.0 3.33 40.0 86 1,800 4,500
C4013RW 24 18 - 36 1,938 85 15.0 2.66 40.0 86 1,200 4,500
C4014RW 24 18 - 36 1,938 85 24.0 1.66 40.0 86 330 4,500
C4015RW 24 18 - 36 1,757 85 +5.0 +3.50 -5.0 -3.50 35.0 83 ±1,000 4,500
C4016RW 24 18 - 36 1,938 85 +12.0 +1.66 -12.00 -1.66 40.0 86 ±150 4,500
C4017RW 24 18 - 36 1,938 85 +15.0 +1.32 -15.00 -1.32 40.0 86 ±82 4,500
C4018RW 24 18 - 36 1,938 85 5.0 5.00 +12.0 +0.60 -12.0 -0.60 40.0 86 1,000/ ±120 4,500
C4019RW 24 18 - 36 1,938 85 5.0 5.00 +15.0 +0.50 -15.0 -0.50 40.0 86 1,800/ ±82 4,500
C4021RW 48 36 - 75 947 50 5.0 8.00 40.0 88 13,600 2,500
C4022RW 48 36 - 75 957 50 12.0 3.33 40.0 87 1,800 2,500
C4023RW 48 36 - 75 957 50 15.0 2.66 40.0 87 1,200 2,500
C4024RW 48 36 - 75 957 50 24.0 1.66 40.0 87 330 2,500
C4025RW 48 36 - 75 868 50 +5.0 +3.50 -5.0 -3.50 35.0 84 ±1,000 2,500
C4026RW 48 36 - 75 957 50 +12.0 +1.66 -12.00 -1.66 40.0 87 ±150 2,500
C4027RW 48 36 - 75 957 50 +15.0 +1.32 -15.00 -1.32 40.0 87 ±82 2,500
C4028RW 48 36 - 75 957 50 5.0 5.00 +12.0 +0.60 -12.0 -0.60 40.0 87 1,000/ ±120 2,500
C4029RW 48 36 - 75 957 50 5.0 5.00 +15.0 +0.50 -15.0 -0.50 40.0 87 1,800/ ±82 2,500
Notes:
1. For triple output models, the voltage accuracy of the auxiliary outputs is ±5%. Derating Curve
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic in parallel with a 10 µF capacitor be placed
from the +Vout pin to the -Vout pin.
3. The unit will recover automatically when the fault condition is removed.
4. Over voltage protection is provided by a zener diode clamp.
5. If the on/off pin (Pin 4) is left open, the unit operates.
6. No load operation will not damage these units, but they may not meet all spec's.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Mechanical Dimensions
External Trim
Pin Connections
Pin Single Dual Triple
1 +Vin +Vin +Vin
2 -Vin -Vin -Vin
4 On/Off On/Off On/Off
5 NC Vout 1 Vout 2
6 +Vout Common Vout 1
7 -Vout Vout 2 Common
8 Trim Trim Vout 3
NC = No Connection
A simple external circuit may be used to adjust
the converter output. To adjust the output DOWN,
Mechanical Notes: connect a 5%, 3W resistor between the plus output
· All dimensions are typical in inches (mm) pin and the Vout trim pin. To adjust the output UP,
· Tolerance x.xx = ±0.01 (±0.25) connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin.
For UP/Down trimming capability, connect a 10 kW
MicroPower Direct potentiometer between the plus and minus outputs
with the wiper arm connected to the Vout trim pin.
The range for the external trim is about ±10%.
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 · TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail: sales@micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de