Hier Klicken für das PDF Dokument!!!
225 WATTS
NO MINIMUIM ORDERS REQUIRED
CE-225 SERIES OUTPUT SPECIFICATIONS
Features Total Output Power 100W Convection cooled
150W 300 LFM Forced Air
Universal 85-264 VAC Input Output Voltage Output 1: +/-0.25%
High Efficiency Centering Output 2: +/-0.25% (X0XX)
Compact 4.75" X 8.0" X 2.0" Size +/-5.0% (X1XX)
Output 3: +/-2.0%
2 Year Warranty
Output 4: +/-2.0%
One to Four Tightly Regulated Outputs (All outputs at 50% load)
EN 60950 ITE Certification Source Regulation Outputs 1-4: 0.5%
EN 60601-1 Medical Certification Load Regulation Output 1:0.5% (10-100% Load
Class B Emissions Per EN 55011/22 Change)
Harmonic Current per EN 61000-3-22 Output 2:
EMC to EN 61000-6-2 & EN 60601-1-12 (X0XX) 0.5% (0-100% Load
Change)
Optional Perforated Cover
(X1XX) 5.0% (10-100%
Load Change)
Output 3: 2.0% (0-100%
Load Change)
Output 4: 2.0% (0-100%
Load Change)
Cross Regulation Output 2: 0.2% (X0XX)
5.0% (X1XX)
Output 3: 2.0%
Output 4: 2.0%
(Output 1 load varied
50-100%))
Output Voltage AdjustOutput1-2:95%-105%(X0XX)
Range Output 1: 95%-105% (X1XX)
Output 1: 85%-105%
INPUT SPECIFICATIONS (1001,4001)
Source Voltagee 85-264 Voltage AC Output 2: 85%-105%
Frequency Range 47-63 Hz (4002,4003)
Source Current Output Noise Outputs 1-4: 1%
True RMS 4.25A At 85V Inputut Turn On Overshoot None
Peak Inrush 30A Transient Response Outputs 1-4:
Peak Repetive 6.0A at 85V Input Volt. Deviation 5.0%
Harmonic Distortion 0.05 Recovery Time 500 MicroS
Efficiency .68 -.80 (Varies by model) Load Change 50% To 100%
Power Factor 0.92 (225 watts, 230V) Output Overvoltage Output 1: 110% to
ENVIRONMENTAL SPECIFICATIONS Protection (Optional) 150%.Shuts
Ambient o o down all
0 C to +70 C Derating: See Power
Operating outputs.Cycle
Rating Chart 0 oC to +50oC
Temperature input to restart
Derating: See Power Rating Chart Output Overpower 250 W Min., Outputs 1
Range
Protection Outputs cycle on/off, auto
Ambient
Storage recovery
-40oC to +85oC Output Overcurrent 110% Min., Outputs 2,3 & 4
Temperature
Protection
Range
Hold Up Time 20 mS Min, 225 W Output
Temperature Outputs 1-4: 0.02%/oC Outputs 120 V Inputt
Coefficient 1-4: 0.02%/oC Start Up Time 3 Seconds
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
SAFETY SPECIFICATIONS GENERAL SPECIFICATIONS
General Protection Class: I Dielectric Strength
Reinforced Insulation 5656 VDC, Primary to
Overvoltage Category: II Secondary, 1 Sec.
Basic Insulation 2121 VDC, Primary to
Pollution Degree: 2 Ground, 1 Sec.
Operational Insulation 707 VDC, Secondary to
Ground, 1 Sec.
Underwriters UL 60950, Third Edition UL
Laboratories 2601 - 1 Second Edition CB Leakage Current <300ÂIA Earth Leakage
File E137708 Report Per IEC 950 (1991) Current
Second Edition A1, A2, A3, Power Fail Signal Logic low with input power
A4 All EN 60950 Deviations (Optional) failure 10 mS minimum
CB Report Per IEC prior to output 1 dropping
601-1-1988 First Edition, A1, 1%
A2 Remote On/Off (Optional)Contact closure shuts off all
outputs
UL CAN/CSA-C22.2 No.
Remote Sense (Single 250mV compensation of
Recognition 60950:00
Models ) output cable losses
Mark for CAN/CSA-C22.2 No.
Mean-Time Between 100,000 Hours min.,
Canada 601-1-M90
Failures MIL-HDBK-217F, 25o C, GB
File E137708
Weight 3.0 Lbs.
TUV EN 60950:2000
EN 60601-1/A2:1995
Low Voltage Directive
MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4
CE-225-4001 +3.3V/25A (1) +5V/8A(1) +12V/2A (1) -12V/2A(1)
CE-225-4002 +5V/25A (1) +3.3V/8A(1) +12V/2A -12V/2A
CE-225-4003 +5V/25A (1) +3.3V/8A(1) +15V/2A -15V/2A
CE-225-4004 +5V/25A (1) -5.2V/8A (1) +12V/2A -12V/2A
CE-225-4005 +5V/25A (1) -5.2V/8A (1) +15V/2A -15V/2A
CE-225-4006 +5V/25A (1) +12V/8A (1) +12V/2A -12V/2A
CE-225-4007 +5V/25A (1) +12V/8A (1) +15V/2A -15V/2A
CE-225-4008 +5V/25A (1) +12V/8A (1) +9V/2A -9V/2A
CE-225-4101 +5V/25A (1) +24V/8A (1) +12V/2A -12V/2A
CE-225-4102 +5V/25A (1) +24V/8A (1) +15V/2A -15V/2A
CE-225-4104 +24V/6A (1) +24V/3A (1) +12V/2A 5V/2A
CE-225-3001 +5V/25A (1) +12V/8A (1) -12V/2A
CE-225-3002 +5V/25A (1) +15V/8A (1) -15V/2A
CE-225-2001 +12V/10A(1) -12V/8A(1)
CE-225-2002 +15V/10A -15V/8A(1)
CE-225-2003 +5V/25A (1) +12V/8A
CE-225-2004 +5.2V/30A -9V/6A
CE-225-2005 +3.3V/25A +12V/8A
CE-225-2101 +5V/25A (1) +24V/8A (1)
CE-225-1001 3.3V/45A(6)
CE-225-1002 5V/45A(6)
CE-225-1003 12V/18.8A(1)
CE-225-1004 15V/15A(1)
CE-225-1005 24V/9.4A(1)
CE-225-1006 28V/8A(1)
CE-225-1007 48V/4.7A(1)
CE-225-1008 48V/4.7A(1)
CE-225-1009 39V/5.8A(1)
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Notes
Consult factory for alternate output configuration.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25o C unless otherwise stated and are subjected to change without
notice.
Specify optional perforated cover, overvoltage protection or remote on/off when ordering.
CE-225 SERIES MECHANICAL SPECIFICATIONS
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
APPLICATIONS INFORMATION
1. Derated 20% when convection cooled. 15. This power supply has been safety approved
2. Each output can deliver its rated current but and final tested using a DC dielectric strength
total output power must not exceed 150 or 225 test. Please consult factory before performing
watts as determined by the cooling method. AC dielectric strength test.
3. Rated 30 amps maximum when convection 16. Maximum screw penetration into bottom
cooling only. chassis mounting holes is .187 inches.
4. Free air convection cooling, 150 watts
maximum output power. Maximum Output Power vs. Ambient
5. Forced air cooling rating of 225 watts requires Temperature
an air speed of 300 linear feet per minute
flowing past a point one inch above the main
isolation transformer.
6. Semiconductor case temperature must not
exceed 110oC.
7. Sufficient area must be provided around
convection cooled power supplies to allow
natural movement of air develop.
8. 300 linear feet per minute of airflow must be
maintained one inch above any point of the
heatsink in the direction shown when forced air
cooling is required.
9. This product is intended for use as a
CONNECTOR SPECIFICATIONS
professionally installed component within
information technology and medical equipment. .156 friction lock header
mates with Molex
10. A minimum load of 10% is required on output
09-50-3031 or equivalent
one to insure proper regulation of remaining P1 AC Input
crimp terminal housing
outputs.
with Molex 08-50-0189 or
11. Remote sense terminals may be used to equivalent crimp terminal.
compensate for cable losses up to 250mV. The 6-32 screw down terminal
use of a twisted pair is recommended as well as P2 DC Output(Single) mates with #6 ring tongue
a decoupling capacitor (0.1 0 10ÂIF) and a
terminal.(10 in-lb max)
capacitor of 100ÂIF/amp connected across the
.156 friction lock header
load. mates with Molex
12. Peak to peak output ripple and noise is 09-50-3181 or equivalent
measured directly at the output P2 DC Output(Multiple)
crimp terminal housing
terminals of the power supply, without the use with Molex 08-50-0189 or
of the probe ground lead or retractable tip, 20 equivalent crimp terminal.
MHz bandwidth. .187 quick disconnect
13. This product includes only one fuse in the input G Ground terminal.
circuit. In consideration of Clause 57.6 of UL .100 friction lock header
2601-1, a second fuse may be required in the mates with Molex
end product. 22-01-2087 or equivalent
P3 Option/Sense(Single)
14. This product was type tested and safety crimp terminal housing
certificated using the the dielectric strength test with Molex type 6459 or
voltages listed in Table V of UL 60601-1. In equivalent crimp terminal.
consideration of clause 20.4g, care must be .100 friction lock header
taken to insure the voltage applied to a mates with Molex
reinforced insulation does not over stress basic Option/Sense(Multiple) 22-01-2047 or equivalent
P3
insulation. Secondary to ground capacitors may crimp terminal housing
need to be removed prior to performing a with Molex type 6459 or
dielectric strength type test on the end product. equivalent crimp terminal.
It is highly recommended that the DC test RECOMMENDED AIR FLOW DIRECTION
voltages listed in DVB.1. Annex DVB are not 1.Optimum 2.Good 3.Fair
exceeded during a production-line dielectric
strength test of the assembled end product.
Please consult factory for further information.
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de