Hier Klicken für das PDF Dokument!!!

                   225 WATTS
                                                       NO MINIMUIM ORDERS REQUIRED
                 CE-225 SERIES                             OUTPUT SPECIFICATIONS

Features                                             Total Output Power   100W Convection cooled
                                                                          150W 300 LFM Forced Air
       Universal 85-264 VAC Input                   Output Voltage        Output 1: +/-0.25%
       High Efficiency                              Centering             Output 2: +/-0.25% (X0XX)
       Compact 4.75" X 8.0" X 2.0" Size                                              +/-5.0%      (X1XX)
                                                                          Output 3: +/-2.0%
       2 Year Warranty
                                                                          Output 4: +/-2.0%
       One to Four Tightly Regulated Outputs                              (All outputs at 50% load)
       EN 60950 ITE Certification                   Source Regulation     Outputs 1-4: 0.5%
       EN 60601-1 Medical Certification             Load Regulation       Output 1:0.5% (10-100% Load
       Class B Emissions Per EN 55011/22                                  Change)
       Harmonic Current per EN 61000-3-22                                 Output 2:
       EMC to EN 61000-6-2 & EN 60601-1-12                                (X0XX) 0.5%       (0-100% Load
                                                                          Change)
       Optional Perforated Cover
                                                                          (X1XX) 5.0%       (10-100%
                                                                          Load Change)
                                                                          Output 3: 2.0% (0-100%
                                                                          Load Change)
                                                                          Output 4: 2.0% (0-100%
                                                                          Load Change)
                                                    Cross Regulation      Output 2: 0.2%         (X0XX)
                                                                                      5.0%      (X1XX)
                                                                          Output 3: 2.0%
                                                                          Output 4: 2.0%
                                                                          (Output 1 load varied
                                                                          50-100%))
                                                    Output Voltage AdjustOutput1-2:95%-105%(X0XX)
                                                    Range                 Output 1: 95%-105% (X1XX)
                                                                          Output 1: 85%-105%
         INPUT SPECIFICATIONS                                             (1001,4001)
Source Voltagee         85-264 Voltage AC                                 Output 2: 85%-105%
Frequency Range         47-63 Hz                                          (4002,4003)
Source Current                                      Output Noise          Outputs 1-4: 1%
True RMS                4.25A At 85V Inputut         Turn On Overshoot     None
Peak Inrush             30A                         Transient Response Outputs 1-4:
Peak Repetive           6.0A at 85V Input           Volt. Deviation       5.0%
Harmonic Distortion 0.05                            Recovery Time         500 MicroS
Efficiency              .68 -.80 (Varies by model)  Load Change           50% To 100%
Power Factor            0.92 (225 watts, 230V)      Output Overvoltage Output 1:           110% to
       ENVIRONMENTAL SPECIFICATIONS                 Protection (Optional)                  150%.Shuts
Ambient             o         o                                                            down all
                   0 C to +70 C Derating: See Power
Operating                                                                                  outputs.Cycle
                   Rating Chart 0 oC to +50oC
Temperature                                                                                input to restart
                   Derating: See Power Rating Chart Output Overpower      250 W Min., Outputs 1
Range
                                                    Protection            Outputs cycle on/off, auto
Ambient
Storage                                                                   recovery
                   -40oC to +85oC                   Output Overcurrent 110% Min., Outputs 2,3 & 4
Temperature
                                                    Protection
Range
                                                    Hold Up Time          20 mS Min, 225 W Output
Temperature        Outputs 1-4: 0.02%/oC Outputs                          120 V Inputt
Coefficient        1-4: 0.02%/oC                    Start Up Time         3 Seconds




                  CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                       Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
      SAFETY SPECIFICATIONS                                    GENERAL SPECIFICATIONS
General                Protection Class:             I Dielectric Strength
                                                       Reinforced Insulation    5656 VDC, Primary to
                       Overvoltage Category:         II                         Secondary, 1 Sec.
                                                        Basic Insulation        2121 VDC, Primary to
                       Pollution Degree:             2                          Ground, 1 Sec.
                                                        Operational Insulation  707 VDC, Secondary to
                                                                                Ground, 1 Sec.
          Underwriters UL 60950, Third Edition UL
          Laboratories 2601 - 1 Second Edition CB       Leakage Current         <300ÂIA Earth Leakage
          File E137708 Report Per IEC 950 (1991)                                Current
                       Second Edition A1, A2, A3,       Power Fail Signal       Logic low with input power
                       A4 All EN 60950 Deviations       (Optional)              failure 10 mS minimum
                       CB Report Per IEC                                        prior to output 1 dropping
                       601-1-1988 First Edition, A1,                            1%
                       A2                               Remote On/Off (Optional)Contact closure shuts off all
                                                                                outputs
          UL           CAN/CSA-C22.2 No.
                                                        Remote Sense (Single    250mV compensation of
          Recognition 60950:00
                                                        Models )                output cable losses
          Mark for     CAN/CSA-C22.2 No.
                                                        Mean-Time Between       100,000 Hours min.,
          Canada       601-1-M90
                                                        Failures                MIL-HDBK-217F, 25o C, GB
          File E137708
                                                        Weight                  3.0 Lbs.
          TUV          EN 60950:2000
                       EN 60601-1/A2:1995
                       Low Voltage Directive

                     MODEL LISTING
Model                  Output 1                 Output 2             Output 3             Output 4
CE-225-4001            +3.3V/25A (1)            +5V/8A(1)            +12V/2A (1)          -12V/2A(1)
CE-225-4002            +5V/25A (1)              +3.3V/8A(1)          +12V/2A              -12V/2A
CE-225-4003              +5V/25A (1)            +3.3V/8A(1)          +15V/2A              -15V/2A
CE-225-4004              +5V/25A (1)            -5.2V/8A (1)         +12V/2A              -12V/2A
CE-225-4005              +5V/25A (1)            -5.2V/8A (1)         +15V/2A              -15V/2A
CE-225-4006              +5V/25A (1)            +12V/8A (1)          +12V/2A              -12V/2A
CE-225-4007              +5V/25A (1)            +12V/8A (1)          +15V/2A              -15V/2A
CE-225-4008              +5V/25A (1)            +12V/8A (1)          +9V/2A               -9V/2A
CE-225-4101              +5V/25A (1)            +24V/8A (1)          +12V/2A              -12V/2A
CE-225-4102              +5V/25A (1)            +24V/8A (1)          +15V/2A              -15V/2A
CE-225-4104              +24V/6A (1)            +24V/3A (1)          +12V/2A              5V/2A
CE-225-3001              +5V/25A (1)            +12V/8A (1)                               -12V/2A
CE-225-3002              +5V/25A (1)            +15V/8A (1)                               -15V/2A
CE-225-2001              +12V/10A(1)            -12V/8A(1)
CE-225-2002              +15V/10A               -15V/8A(1)
CE-225-2003              +5V/25A (1)            +12V/8A
CE-225-2004              +5.2V/30A              -9V/6A
CE-225-2005              +3.3V/25A              +12V/8A
CE-225-2101              +5V/25A (1)            +24V/8A (1)
CE-225-1001              3.3V/45A(6)
CE-225-1002              5V/45A(6)
CE-225-1003              12V/18.8A(1)
CE-225-1004              15V/15A(1)
CE-225-1005              24V/9.4A(1)
CE-225-1006              28V/8A(1)
CE-225-1007              48V/4.7A(1)
CE-225-1008              48V/4.7A(1)
CE-225-1009              39V/5.8A(1)




                    CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                         Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Notes

Consult factory for alternate output configuration.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25o C unless otherwise stated and are subjected to change without
notice.
Specify optional perforated cover, overvoltage protection or remote on/off when ordering.

    CE-225 SERIES MECHANICAL SPECIFICATIONS




              CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                   Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
   Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
     APPLICATIONS INFORMATION
 1. Derated 20% when convection cooled.                 15. This power supply has been safety approved
 2. Each output can deliver its rated current but             and final tested using a DC dielectric strength
    total output power must not exceed 150 or 225             test. Please consult factory before performing
    watts as determined by the cooling method.                AC dielectric strength test.
 3. Rated 30 amps maximum when convection                 16. Maximum screw penetration into bottom
    cooling only.                                             chassis mounting holes is .187 inches.
 4. Free air convection cooling, 150 watts
    maximum output power.                                       Maximum Output Power vs. Ambient
 5. Forced air cooling rating of 225 watts requires                            Temperature
    an air speed of 300 linear feet per minute
    flowing past a point one inch above the main
    isolation transformer.
 6. Semiconductor case temperature must not
    exceed 110oC.
 7. Sufficient area must be provided around
    convection cooled power supplies to allow
    natural movement of air develop.
 8. 300 linear feet per minute of airflow must be
    maintained one inch above any point of the
    heatsink in the direction shown when forced air
    cooling is required.
 9. This product is intended for use as a
                                                               CONNECTOR SPECIFICATIONS
    professionally installed component within
    information technology and medical equipment.                                   .156 friction lock header
                                                                                    mates with Molex
10. A minimum load of 10% is required on output
                                                                                    09-50-3031 or equivalent
    one to insure proper regulation of remaining        P1 AC Input
                                                                                    crimp terminal housing
    outputs.
                                                                                    with Molex 08-50-0189 or
11. Remote sense terminals may be used to                                           equivalent crimp terminal.
    compensate for cable losses up to 250mV. The                                    6-32 screw down terminal
    use of a twisted pair is recommended as well as P2 DC Output(Single)            mates with #6 ring tongue
    a decoupling capacitor (0.1 0 10ÂIF) and a
                                                                                    terminal.(10 in-lb max)
    capacitor of 100ÂIF/amp connected across the
                                                                                    .156 friction lock header
    load.                                                                           mates with Molex
12. Peak to peak output ripple and noise is                                         09-50-3181 or equivalent
    measured directly at the output                     P2 DC Output(Multiple)
                                                                                    crimp terminal housing
    terminals of the power supply, without the use                                  with Molex 08-50-0189 or
    of the probe ground lead or retractable tip, 20                                 equivalent crimp terminal.
    MHz bandwidth.                                                                  .187 quick disconnect
13. This product includes only one fuse in the input G Ground                       terminal.
    circuit. In consideration of Clause 57.6 of UL                                  .100 friction lock header
    2601-1, a second fuse may be required in the                                    mates with Molex
    end product.                                                                    22-01-2087 or equivalent
                                                        P3 Option/Sense(Single)
14. This product was type tested and safety                                         crimp terminal housing
    certificated using the the dielectric strength test                             with Molex type 6459 or
    voltages listed in Table V of UL 60601-1. In                                    equivalent crimp terminal.
    consideration of clause 20.4g, care must be                                     .100 friction lock header
    taken to insure the voltage applied to a                                        mates with Molex
    reinforced insulation does not over stress basic       Option/Sense(Multiple) 22-01-2047 or equivalent
                                                        P3
    insulation. Secondary to ground capacitors may                                  crimp terminal housing
    need to be removed prior to performing a                                        with Molex type 6459 or
    dielectric strength type test on the end product.                               equivalent crimp terminal.
    It is highly recommended that the DC test                RECOMMENDED AIR FLOW DIRECTION
    voltages listed in DVB.1. Annex DVB are not          1.Optimum 2.Good 3.Fair
    exceeded during a production-line dielectric
    strength test of the assembled end product.
    Please consult factory for further information.