Hier Klicken für das PDF Dokument!!!

  CENT1120
  Universal 120 Watt Series



· 100-240 VAC Universal Input
· Desktop Style
· Complies with EMI/RFI Regulations
· CE Compliant (LVD, EMC, WEEE, RoHS)
· Impact Resistant, Non-vented Polycarbonate Enclosure
· IPX1 Compliant
· Modified and Custom Designs also Available
· Meets ENERGY STAR Criteria Level IV and
  EISA Requirements -- see page three for details




  International Safety Standard Approvals




  Specifications

  Output Specifications                                                              Input Specifications
  Line Voltage Regulation      Including Cord      2%                                Voltage                                           100-240VAC -10%, +10%
  Load Voltage Regulation      Including Cord      5%                                Line Frequency                                    47-63Hz
  Ripple                                           1% Vp-p of Vnorm, max.            Input Current                                     2.0A max. @ 90VAC
  Transient Response                               5 msec from 25% to 75%            Protection                                        Internal primary
                                                   load change typ., <+/-5%                                                            current fuse
                                                   Over/Undershoot
                                                                                     Power Factor Correction                           Complies with
  Turn on Delay                                    Less than 3s over entire                                                            EN61000-3-2 class D
                                                   input range
  Turn on Overshoot                                Less than +/-5% of Vnorm.
                                                   over entire input range
                                                                                     Environmental Specifications
  Over Temperature Protection                      Active                            Thermal Performance     Operating Temperature 0° C to 40° C
                                                                                                                                   with no Derating
  Over Current Protection                          Higher than 120% of Inorm.
                                                   Cyclic Mode                       Cooling                 Convectional              Non-ventilated Enclosure

  Short Circuit Protection                         Cyclic Mode                       Relative Humidity       Non-condensing            5% to 95%

  Temp. Coefficient                                ±0.05% / °C                       Altitude                                          0-10,000 feet

  Protection Mode                                  Auto Recovery OCP, SCP            Storage Temp                                      -20° C to +85° C
                                                   Latch protection OTP ,OVP




                                                      CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
SL Power Electronics Corp · 6050 King Drive · Ventura, CA 93003 · Phone:805.486.4565 · Fax:858.712.2040 · Email:info@slpower.com · www.slpower.com
                                                      Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                      info@compumess.de · www.compumess.de · www.netzteile.de
  CENT1120
  Universal 120 Watt Series

                                                                                  For the most current data and application support visit www.slpower.com



                                       Output                                 Output Currents                                  Max                     Max
  Ault Part Number                     Voltage                       Min                           Max                         Watts                   OVP
  CENT1120A1251F01                       12 V                        0.00 A                        9.17 A                      110.0 W*                20 V
  CENT1120A1551F01                       15 V                        0.00 A                        7.33 A                      110.0 W                 25 V
  CENT1120A1851F01                       18 V                        0.00 A                        6.67 A                      120.0 W                 27 V
  CENT1120A2451F01                       24 V                        0.00 A                        5.00 A                      120.0 W                 36 V
  CENT1120A4803F01                       48 V                        0.00 A                        2.50 A                      120.0 W                 72 V

*12V model rated 100W with input voltages rated 100-110VAC, 110W with input voltages rated 110VAC-240VAC



  General Specifications                                                                Ault Part Number Key
  Topology                 Two stage conversion and Quasi-resonate Flyback              C              E          N        T              1           120

  Dielectric Withstand     Primary-Secondary         3000VAC, 4242VDC                   Commercial     External   Input    Factory        No. of      Output
                           Primary-Ground            1500VAC, 2121VDC                                             Range    Location       Outputs     Wattage
                           Secondary-Ground          500VDC
  Spacing                  Primary-Secondary         8mm min.
                                                                                        Input Connectors
  Leakage Current 1                                  Primary side to Earth< 3.5
                                                     mA in Normal State
  Leakage Current 2                                  Output- to Earth<0.25mA            IEC320
                                                     in Normal State                    w/ground
                                                                                        C14
  Efficiency               (excluding cord)          88% Typical                        (F)

  MTBF                                               100,000 Calculated Hours
  Hold-up Time                                       16.7 msec typ. @ 110VAC
                                                     30 msec typ. @ 220VAC
                                                                                        Optional Features
                                                                                        Private label marking
  Certifications                                     UL, EN (TUV), EN60601-1
  Weight                   (excluding cord)          24 oz (684 g)
  Case and Dimension                                 6.6L X 3.2W X 1.6H (in)            Output Connectors
                                                     167L X 82W X 40H (mm)
  Case Material                                      Black 94V0 Polycarbonate
  Cord and Connector                                 1.0m long for 12V 1.8m
                                                     long for 15V/18V/24V/48V,
                                                     18AWG cable with AULT
                                                     #51 connector. For
                                                     12V/15V/18V/24V, 18AWG
                                                     cable with AULT #3 plug
                                                     for 48V
  EMI/EMC Information
  Conducted Emissions      EN55022 Class B
  Radiated Emissions       EN55022, FCC Part15 Class B
  Line freq. Harmonics     EN61000-3-2 Class D
  Voltage Fluctuations     EN61000-3-3 Complies
  ESD                      EN61000-4-2 Cont. 6kV, air 8KV
  Radiated Immunity        EN61000-4-3 3V/m
  Fast Transients (EFT)    EN61000-4-4 2KV 5KHz
  Line Surge Immunity      EN61000-4-5 2KV CM, 1KV Diff.
  Conducted Immunity       EN61000-4-6 3Vrms
  Power Freq. Mag. Field   EN61000-4-8, 3A/m Perf Criteria A
  Voltage Dip Immunity     EN61000-4-11, 70% UT for 10mS, 40% UT for
                           100mS, <5% UT for 5000mS, Perf Criteria A, B, B




                                                                                                                                                                2 of 3

SL Power Electronics Corp. · 6050 King Drive · Ventura, CA 93003 · Phone:805.486.4565 · Fax:805.487.8911 · Email:info@slpower.com · www.slpower.com
   CENT1120
   Universal 120 Watt Series

                                                                                           For the most current data and application support visit www.slpower.com


   2007 Energy Independence and Security Act ­ EISA
   The Energy Independence and Security Act of 2007 was passed in December of
   2007 and addresses minimum efficiency standards and standby levels for Class
   A external power supplies that are 250 watts and under. This law stipulates
   that external power supplies manufactured on July 1, 2008 and beyond meet
   certain minimum efficiency and standby criteria as defined below.
   Minimum Efficiency Criteria
   Active mode is defined as when a power supply's input is connected to line
   voltage AC and its output is connected to a DC or AC load drawing a portion
   of the product's power output. Depending on the power rating for the power
   supply, it must meet the minimum efficiency criteria outlined below.
   Energy-Efficiency Criteria for Active Mode:
   output power on                minimum average
   adapter label                  efficiency percentage
   0 to less than 1 watt            0.50 * output power on adapter label
   > 1 to 51 watts                  [0.09 * Ln (output power on adapter
                                  label )] + 0.50
   > 51 watts                       0.85
   The power supply must also meet a requirement for when its input is
   connected to a line voltage AC but its output is not connected to a load.
   Depending on the power output of the supply, it must keep its energy
   consumption below the following values.
   Energy Consumption Criteria for No Load Mode:
   output power on             maximum power consumption
   adapter label               in no-load mode
   0 to < 250 watts              0.5 watts




                                                                                                                                                                      3 of 3

SL Power Electronics Corp · 6050 King Drive · Ventura, CA 93003 · Phone:805.486.4565 · Fax:858.712.2040 · Email:info@slpower.com · www.slpower.com
                                                                           CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
                                                                         Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.7/9/08                                                               info@compumess.de · www.compumess.de · www.netzteile.de