                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                  Input
Key Features:                     Parameter                                                              Conditions                          Min.        Typ.      Max.           Units
· 1W Output Power                                                                                                        5 VDC Input          4.75       5.0        5.25
                                  Input Voltage Range                                                                  12 VDC Input           11.4       12.0       12.6          VDC
· Tightly Regulated
                                                                                                                       24 VDC Input           22.8       24.0       25.2
· Single & Dual Outputs
                                  Input Filter                                                                                Internal Capacitor
· Miniature SIP Case
                                  Reverse Polarity Input Current                                                                                                     0.3            A
· 1,000 VDC Isolation             Output
· >3.5 MHour MTBF                Parameter                                                               Conditions                          Min.        Typ.      Max.           Units
· 24 Standard Models             Output Voltage Accuracy                                                                                                            ±3.0            %
· Industry Standard Pin-Out      Output Voltage Balance                                         Dual Output , Balanced Loads                             ±0.1       ±1.0            %
· LOWEST COST!!                  Line Regulation                                                               For Vin Min to Max                                  ±0.25            %
                                 Load Regulation (Note 1)                                               For Iout = 10% to 100%                                      ±1.0            %
                                 Ripple & Noise (20 MHz) (Note 3)                                                                                         10         20         mV P - P
                                 Output Power Protection                                                                                      120                                   %
                                 Temperature Coefficient                                                                                                           ±0.03          %/ºC
                                  Output Short Circuit                                                                      Momentary (1.0 Sec.)
                                  General
                                  Parameter                                                              Conditions                          Min.        Typ.      Max.           Units
                                  Isolation Voltage                                                                       60 Seconds         1,000                                VDC
  RoHS Compliant                  Isolation Resistance                                                                        500 VDC        1,000                                 M
                                  Isolation Capacitance                                                                  100 kHz, 1V                      60                        pF
                                  Switching Frequency                                                                                                    100                       kHz
                                  Environmental
                                  Parameter                                                              Conditions                          Min.        Typ.      Max.           Units
                                  Operating Temperature Range                                                                Ambient          -40        +25        +85             ºC
                                  Operating Temperature Range                                                                      Case       -40                   +90             ºC
                                  Storage Temperature Range                                                                                   -55                  +125             ºC
                                  Cooling                                                                                    Free Air Convection
                                  Humidity                                                                   RH, Non-condensing                                      95             %
MicroPower Direct                 Physical
292 Page Street
Suite D                           Case Size (Single Output)                                                                 0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm)
Stoughton, MA 02072               Case Size (Dual Output)                                                                   1.08 x 0.37 x 0.47 Inches (27.5 x 9.5 x 12.0 mm)
USA                               Case Material                                                                                      Non-Conductive Black Plastic (UL94-V0)
                                  Weight                                                                                                                                   0.07 Oz (2.1g)
T: (781) 344-8226
F: (781) 344-8481                 Reliability Specifications
E: sales@micropowerdirect.com     Parameter                                                              Conditions                          Min.        Typ.      Max.           Units
W: www.micropowerdirect.com       MTBF                                                    MIL HDBK 217F, 25ºC, Gnd Benign                     3.5                               MHours
                                  Absolute Maximum Ratings
                                  Parameter                                                              Conditions                          Min.        Typ.      Max.           Units
                                                                                                                         5 VDC Input          -0.7                   9.0
                                  Input Voltage Surge (1 Sec)                                                          12 VDC Input           -0.7                  18.0          VDC
                                                                                                                       24 VDC Input           -0.7                  30.0
                                  Lead Temperature                                               1.5 mm From Case For 10 Sec                                        300             ºC
                                  Internal Power Dissipation                                                               All Models                               450           mW
                                       Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.


                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                            info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
                               Input                                       Output                          Fuse Rating
  Model                                                                                       Efficiency
               Voltage (VDC)           Current (mA)              Voltage Current   Current                 Slow-Blow
 Number                                                                                        (%, Typ)
            Nominal     Range      Full-Load No-Load              (VDC) (mA, Max) (mA, Min)                   (mA)
D101ER         5     4.75 - 5.25      294        30                 5.0   200.0      20.0        68            500
D102ER         5     4.75 - 5.25      286        30                 9.0   111.0      12.0        70            500
D103ER         5     4.75 - 5.25      282        30                12.0    83.0       9.0        71            500
D104ER         5     4.75 - 5.25      278        30                15.0    67.0       7.0        72            500
D105ER         5     4.75 - 5.25      290        30                ±5.0  ±100.0     ±10.0        69            500
D106ER         5     4.75 - 5.25      286        30                ±9.0   ±56.0      ±6.0        70            500
D107ER         5     4.75 - 5.25      278        30               ±12.0   ±42.0      ±5.0        72            500
D108ER         5     4.75 - 5.25      278        30               ±15.0   ±33.0      ±4.0        72            500
D111ER        12     11.4 - 12.6      121        15                 5.0   150.0      15.0        69            200
D112ER        12     11.4 - 12.6      117        15                 9.0   111.0      12.0        71            200
D113ER        12     11.4 - 12.6      116        15                12.0    83.0       9.0        72            200
D114ER        12     11.4 - 12.6      116        15                15.0    67.0       7.0        72            200
D115ER        12     11.4 - 12.6      119        15                ±5.0  ±100.0     ±10.0        70            200
D116ER        12     11.4 - 12.6      116        15                ±9.0   ±56.0      ±6.0        72            200
D117ER        12     11.4 - 12.6      114        15               ±12.0   ±42.0      ±5.0        73            200
D118ER        12     11.4 - 12.6      114        15               ±15.0   ±33.0      ±4.0        73            200
D121ER        24     22.8 - 25.2       59         8                 5.0   150.0      15.0        70            100
D122ER        24     22.8 - 25.2       58         8                 9.0   111.0      12.0        72            100
D123ER        24     22.8 - 25.2       57         8                12.0    83.0       9.0        73            100
D124ER        24     22.8 - 25.2       57         8                15.0    67.0       7.0        73            100
D125ER        24     22.8 - 25.2       58         8                ±5.0  ±100.0     ±10.0        72            100
D126ER        24     22.8 - 25.2       58         8                ±9.0   ±56.0      ±6.0        72            100
D127ER        24     22.8 - 25.2       57         8               ±12.0   ±42.0      ±5.0        73            100
D128ER        24     22.8 - 25.2       57         8               ±15.0   ±33.0      ±4.0        73            100
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.       Derating Curve
2. These units should not be operated with a load under 10% of full load.
   Operation at no-load may cause damage to the unit.
3. These converters will operate without external components. However,
   when measuring output ripple, it is recommended that an external ceramic
   capacitor be placed from the +Vout pin to the -Vout pin for single output
   units and from each output to common for dual output units. An input
   capacitor will enhace
   stability over tem-                    Input           Output Capacitor
   perature and input            Vin                 Vout
                                       Capacitor           Single    Dual
   line variations. Rec-
   ommended capacitor           5 VDC    4.7 µF     5 VDC 10.0 µF 4.7 µF
   values are given in         12 VDC    2.2 µF     9 VDC  4.7 µF   2.2 µF
   the table at right. For     24 VDC    1.0 µF    12 VDC 2.2 µF    1.0 µF
   applications requiring
                                                   15 VDC 1.0 µF 0.47 µF
   very low output noise
   levels, a simple LC filter should be effective.
4. It is recommended that a fuse be used on the input of a power supply for
   protection. See the Model Selection table above for the correct rating.


                               Mechanical Dimensions (Single Output)                      Mechanical Dimensions (Dual Output)



       Pin
    Connections
 Pin    Single    Dual
  1     +Vin    +Vin
  2     -Vin    -Vin
  4    -Vout No Pin
  6    +Vout No Pin
  7    No Pin +Vout
  9    No Pin -Vout
 10    No Pin Common




                                                                                                            Notes:


                      MicroPower Direct
                                                                                                            · All dimensions are typical in inches (mm)
                                                                                                            · Tolerance x.xx = ±0.01 (±0.25)
                                                                                                            · Pin 1 is marked by a "dot" or indentation
                                                                                                              on the side of the unit
                                        www.micropowerdirect.com
                                                         CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                         Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                         info@compumess.de · www.compumess.de · www.netzteile.de