D200E Series
Low Cost, 2W SIP
Single & Dual Output
DC/DC Converters New Budget Saver!!
Electrical Speci cations
Speci cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speci cations subject to change without notice.
Input
Key Features: Parameter Conditions Min. Typ. Max. Units
2W Output Power 5 VDC Input 4.5 5.0 5.5
Miniature SIP Case Input Voltage Range 12 VDC Input 10.8 12.0 13.2 VDC
Single & Dual Outputs 24 VDC Input 21.6 24.0 26.4
Input Filter Internal Capacitor
1,000 VDC Isolation
Reverse Polarity Input Current 0.3 A
>2 MHour MTBF
Output
24 Standard Models
Parameter Conditions Min. Typ. Max. Units
LOWEST COST!!
Output Voltage Accuracy ±1.0 ±3.0 %
Output Voltage Balance Dual Output , Balanced Loads ±0.1 ±1.0 %
Line Regulation For Vin Change of 1% ±1.2 %
Load Regulation See Model Selection Guide
Ripple & Noise (20 MHz) 100 150 mV P - P
Output Power Protection 120 %
Temperature Coef cient ±0.02 ±0.03 %/ºC
Output Short Circuit Momentary (1.0 Sec.)
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 1,000 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz, 1V 60 pF
Switching Frequency 60 75 100 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -40 +25 +85 ºC
Operating Temperature Range Case -40 +90 ºC
Storage Temperature Range -55 +125 ºC
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
MicroPower Direct Physical
232 Tosca Drive Case Size (5V 12V & 24V Input Models) 0.77 x 0.28 x 0.40 Inches (19.6 x 7.0 x 10.2 mm)
Stoughton, MA 02072
USA Case Material Non-Conductive Black Plastic (UL94-V0)
Weight 0.07 Oz (2.1g)
T: (781) 344-8226
F: (781) 344-8481 Reliability Speci cations
E: sales@micropowerdirect.com Parameter Conditions Min. Typ. Max. Units
W: www.micropowerdirect.com MTBF MIL HDBK 217F, 25ºC, Gnd Benign 1.0 MHours
Absolute Maximum Ratings
Parameter Conditions Min. Typ. Max. Units
5 VDC Input -0.7 9.0
Input Voltage Surge (1 Sec) 12 VDC Input -0.7 18.0 VDC
24 VDC Input -0.7 30.0
Lead Temperature 1.5 mm From Case For 10 Sec 300 ºC
Internal Power Dissipation All Models 450 mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output Load Fuse Rating
Model Ef ciency
Voltage (VDC) Current (mA) Voltage Current Current Regulation Slow-Blow
Number (%, Typ)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) (mA)
D201E 5 4.5 - 5.5 513 30 5.0 400.0 40.0 15 78 1,000
D202E 5 4.5 - 5.5 513 30 9.0 222.0 23.0 15 78 1,000
D203E 5 4.5 - 5.5 506 30 12.0 167.0 17.0 15 79 1,000
D204E 5 4.5 - 5.5 506 30 15.0 133.0 14.0 15 79 1,000
D205E 5 4.5 - 5.5 513 30 ±5.0 ±200.0 ±20.0 15 78 1,000
D206E 5 4.5 - 5.5 506 30 ±9.0 ±111.0 ±12.0 15 79 1,000
D207E 5 4.5 - 5.5 506 30 ±12.0 ±83.0 ±9.0 15 79 1,000
D208E 5 4.5 - 5.5 500 30 ±15.0 ±67.0 ±7.0 15 80 1,000
D211E 12 10.8 - 13.2 214 15 5.0 400.0 40.0 15 78 500
D212E 12 10.8 - 13.2 208 15 9.0 222.0 23.0 15 80 500
D213E 12 10.8 - 13.2 208 15 12.0 167.0 17.0 15 80 500
D214E 12 10.8 - 13.2 206 15 15.0 133.0 14.0 15 81 500
D215E 12 10.8 - 13.2 211 15 ±5.0 ±200.0 ±20.0 15 79 500
D216E 12 10.8 - 13.2 211 15 ±9.0 ±111.0 ±12.0 15 79 500
D217E 12 10.8 - 13.2 208 15 ±12.0 ±83.0 ±9.0 15 80 500
D218E 12 10.8 - 13.2 203 15 ±15.0 ±67.0 ±7.0 15 82 500
D221E 24 21.6 - 26.4 105 8 5.0 400.0 40.0 15 79 200
D222E 24 21.6 - 26.4 104 8 9.0 222.0 23.0 15 80 200
D223E 24 21.6 - 26.4 103 8 12.0 167.0 17.0 15 81 200
D224E 24 21.6 - 26.4 102 8 15.0 133.0 14.0 15 82 200
D225E 24 21.6 - 26.4 102 8 ±5.0 ±200.0 ±20.0 15 82 200
D226E 24 21.6 - 26.4 104 8 ±9.0 ±111.0 ±12.0 15 80 200
D227E 24 21.6 - 26.4 103 8 ±12.0 ±83.0 ±9.0 15 81 200
D228E 24 21.6 - 26.4 102 8 ±15.0 ±67.0 ±7.0 15 82 200
Notes:
1. Output load regulation is speci ed for a load change of 10% to
Derating Curve
100%.
2. These units should not be operated with a load under 10% of full
load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended that
an external ceramic capacitor be placed from the +Vout pin to the
-Vout pin for single output units and from each output to common
for dual output units. An input capacitor will enhace stability over
temperature and input line variations. Recommended capacitor
values are given in the table below. For applications requiring
very low output noise levels, a simple LC lter should be effec-
tive.
Input Output Capacitor
Vin Vout
Capacitor Single Dual
5 VDC 4.7 F 5 VDC 10.0 F 4.7 F
12 VDC 2.2 F 9 VDC 4.7 F 2.2 F
24 VDC 1.0 F 12 VDC 2.2 F 1.0 F Mechanical Dimensions
15 VDC 1.0 F 0.47 F
4. Dual output units may be connected to provide a 10V, 18V, 24V
or 30 VDC output. To do this, connect the load across the posi-
tive (+Vout) and negative (-Vout) outputs and oat the output
common
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for the
correct rating.
Pin Connections
Pin Single Dual Pin Single Dual
1 +Vin +Vin 5 No Pin Common
2 -Vin -Vin 6 +Vout +Vout
4 -Vout -Vout
Notes: All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a "dot" or indentation on the side of the unit
MicroPower Direct CompuMess Elektronik GmbH
Lise-Meitner-Str.1, 85716 Unterschleissheim
Tel 089-321501-0 Fax 089-321501-11
www.micropowerdirect.com http://www.compumess.de oder http://www.netzteile.de