D200EI Series
Low Cost, 2W SIP
High Isolation
DC/DC Converters A Budget Saver!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features: Parameter Conditions Min. Typ. Max. Units
· 2W Output Power 5 VDC Input 4.5 5.0 5.5
· Miniature SIP Case Input Voltage Range 12 VDC Input 10.8 12.0 13.2 VDC
· UL Approved (File E245422) 24 VDC Input 21.6 24.0 26.4
· Single & Dual Outputs Input Filter Internal Capacitor
· 3,000 VDC Isolation Reverse Polarity Input Current 0.3 A
· >3.5 MHour MTBF Output
· 24 Standard Models Parameter Conditions Min. Typ. Max. Units
· LOWEST COST!! Output Voltage Accuracy ±1.0 ±3.0 %
Output Voltage Balance Dual Output , Balanced Loads ±0.1 ±1.0 %
Line Regulation For Vin Change of 1% ±1.2 %
Load Regulation See Model Selection Guide
Ripple & Noise (20 MHz) 100 150 mV P - P
Output Power Protection 120 %
Temperature Coefficient ±0.02 ±0.03 %/ºC
Output Short Circuit Momentary (1.0 Sec.)
RoHS Compliant General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 3,000 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz, 1V 60 pF
Switching Frequency 75 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -40 +25 +85 ºC
Storage Temperature Range -55 +125 ºC
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
Physical
MicroPower Direct Case Size (5V 12V & 24V Input Models) 0.77 x 0.28 x 0.40 Inches (19.6 x 7.0 x 10.2 mm)
292 Page Street Case Material Non-Conductive Black Plastic (UL94-V0)
Suite D Weight 0.07 Oz (2.1g)
Stoughton, MA 02072
USA Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
T: (781) 344-8226 MTBF MIL HDBK 217F, 25ºC, Gnd Benign 3.5 MHours
F: (781) 344-8481 Safety Standards UL 1950, EN 60950, IEC 60950
E: sales@micropowerdirect.com
W: www.micropowerdirect.com Safety Approvals UL, cUL; File No. E245422
Absolute Maximum Ratings
Parameter Conditions Min. Typ. Max. Units
5 VDC Input -0.7 9.0
Input Voltage Surge (1 Sec) 12 VDC Input -0.7 18.0 VDC
24 VDC Input -0.7 30.0
Lead Temperature 1.5 mm From Case For 10 Sec 300 ºC
Internal Power Dissipation All Models 450 mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output Load Fuse Rating
Model Efficiency
Voltage (VDC) Current (mA) Voltage Current Current Regulation Slow-Blow
Number (%, Typ)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) (mA)
D201EI 5 4.5 - 5.5 500 30 5.0 400.0 40.0 15 80 1,000
D202EI 5 4.5 - 5.5 494 30 9.0 222.0 23.0 15 81 1,000
D203EI 5 4.5 - 5.5 488 30 12.0 167.0 17.0 15 82 1,000
D204EI 5 4.5 - 5.5 476 30 15.0 133.0 14.0 15 84 1,000
D205EI 5 4.5 - 5.5 488 30 ±5.0 ±200.0 ±20.0 15 82 1,000
D206EI 5 4.5 - 5.5 482 30 ±9.0 ±111.0 ±12.0 15 83 1,000
D207EI 5 4.5 - 5.5 470 30 ±12.0 ±83.0 ±9.0 15 85 1,000
D208EI 5 4.5 - 5.5 470 30 ±15.0 ±67.0 ±7.0 15 85 1,000
D211EI 12 10.8 - 13.2 208 15 5.0 400.0 40.0 15 80 500
D212EI 12 10.8 - 13.2 201 15 9.0 222.0 23.0 15 83 500
D213EI 12 10.8 - 13.2 198 15 12.0 167.0 17.0 15 84 500
D214EI 12 10.8 - 13.2 196 15 15.0 133.0 14.0 15 85 500
D215EI 12 10.8 - 13.2 201 15 ±5.0 ±200.0 ±20.0 15 83 500
D216EI 12 10.8 - 13.2 198 15 ±9.0 ±111.0 ±12.0 15 84 500
D217EI 12 10.8 - 13.2 194 15 ±12.0 ±83.0 ±9.0 15 86 500
D218EI 12 10.8 - 13.2 194 15 ±15.0 ±67.0 ±7.0 15 86 500
D221EI 24 21.6 - 26.4 103 8 5.0 400.0 40.0 15 81 200
D222EI 24 21.6 - 26.4 99 8 9.0 222.0 23.0 15 84 200
D223EI 24 21.6 - 26.4 98 8 12.0 167.0 17.0 15 85 200
D224EI 24 21.6 - 26.4 97 8 15.0 133.0 14.0 15 86 200
D225EI 24 21.6 - 26.4 99 8 ±5.0 ±200.0 ±20.0 15 84 200
D226EI 24 21.6 - 26.4 98 8 ±9.0 ±111.0 ±12.0 15 85 200
D227EI 24 21.6 - 26.4 96 8 ±12.0 ±83.0 ±9.0 15 87 200
D228EI 24 21.6 - 26.4 96 8 ±15.0 ±67.0 ±7.0 15 87 200
Notes:
1. Output load regulation is specified for a load change of 10% to
Derating Curve
100%.
2. These units should not be operated with a load under 10% of
full load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended
that an external ceramic capacitor be placed from the +Vout
pin to the -Vout pin for single output units and from each out-
put to common for dual output units. An input capacitor will
enhance stability over temperature and input line variations.
Recommended capacitor values are given in the table below.
For applications requiring very low output noise levels, a simple
LC filter should be effective.
Input Output Capacitor
Vin Vout
Capacitor Single Dual
5 VDC 4.7 µF 5 VDC 10.0 µF 4.7 µF
12 VDC 2.2 µF 9 VDC 4.7 µF 2.2 µF
24 VDC 1.0 µF 12 VDC 2.2 µF 1.0 µF Mechanical Dimensions
15 VDC 1.0 µF 0.47 µF
4. Dual output units may be connected to provide a 10V, 18V, 24V
or 30 VDC output. To do this, connect the load across the posi-
tive (+Vout) and negative (-Vout) outputs and float the output
common
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for
the correct rating.
Pin Connections
Pin Single Dual Pin Single Dual
1 +Vin +Vin 6 No Pin Common
2 -Vin -Vin 7 +Vout +Vout
5 -Vout -Vout
Notes:
· All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
· Pin 1 is marked by a "dot" or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.comGmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 ·Telefon (089) 32 15 01 -· · Telefax (089) 32 15 01 -E-Mail: sales@micropowerdirect.com
TEL: (781) 344-8226 0 FAX: (781) 344-8481 · 11
info@compumess.de · www.compumess.de · www.netzteile.de