D200RW Series
Miniature SIP, 2W
Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
Parameter Conditions Min. Typ. Max. Units
· 2W Output Power 5 VDC Input 4.5 5.0 9.0
· 2:1 Input Voltage Range 12 VDC Input 9.0 12.0 18.0
Input Voltage Range VDC
24 VDC Input 18.0 24.0 36.0
· 1,000 VDC Isolation
48 VDC Input 36.0 48.0 72.0
· Short Circuit Protected Input Filter Capacitor Filter
· Miniature SIP Case Input Reflected Ripple Current 35 mA P - P
Reverse Polarity Input Current 1.0 A
· Single & Dual Outputs Short Circuit Input Power 1,500 mW
· 2.7 MH MTBF Output
· Industry Standard Pin-Out Parameter Conditions Min. Typ. Max. Units
Output Voltage Accuracy ±2.0 %
Output Voltage Balance ±2.0 %
Line Regulation Vin = Min to Max ±0.5 %
Load Regulation Iout = 25% to 100% ±1.0 %
Ripple & Noise (20 MHz) 80 mV P - P
Output Power Protection 120 %
Temperature Coefficient ±0.02 %/°C
Output Short Circuit Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
RoHS Compliant Isolation Voltage 60 Seconds 1,000 VDC
Isolation Resistance 1,000 VDC 1,000 M
Isolation Capacitance 100 kHz, 1V 60 pF
Switching Frequency 100 650 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -40 +25 +85 °C
Operating Temperature Range Case +100 °C
Storage Temperature Range -40 +125 °C
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
Physical
Case Size 0.86 x 0.36 x 0.44 Inches (21.89 x 9.2 x 11.2 mm)
Case Material Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
292 Page Street Weight 0.17 Oz (4.8g)
Suite D Remote On/Off
Stoughton, MA 02072 Parameter Conditions Min. Typ. Max. Units
USA Unit On (Note 2) 0 0.8 VDC
Unit Off (Note 2) 5.0 VDC
T: (781) 344-8226 Off Idle Current 5.0 mA
F: (781) 344-8481 Reliability Specifications
E: sales@micropowerdirect.com
Parameter Conditions Min. Typ. Max. Units
W: www.micropowerdirect.com
MTBF MIL HDBK 217F, 25°C, Gnd Benign 2.73 MHours
Absolute Maximum Ratings
Parameter Conditions Min. Typ. Max. Units
5 VDC Input -0.7 12.0
12 VDC Input -0.7 24.0
Input Voltage Surge (1 Sec) VDC
24 VDC Input -0.7 40.0
48 VDC Input -0.7 80.0
Lead Temperature 1.5 mm From Case For 10 Sec 260 °C
Internal Power Dissipation All Models 1,800 mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output Capacitive Fuse Rating
Model Efficiency
Voltage (VDC) Current (mA) Voltage Current Current Load Slow-Blow
Number (%, Typ)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (µF, Max) (mA)
D201RW 5 4.5 - 9.0 492 15 3.3 500.0 125.0 67 3,300 1,500
D202RW 5 4.5 - 9.0 571 15 5.0 400.0 100.0 70 3,300 1,500
D203RW 5 4.5 - 9.0 555 30 12.0 167.0 42.0 72 470 1,500
D204RW 5 4.5 - 9.0 547 30 15.0 133.0 33.0 73 470 1,500
D205RW 5 4.5 - 9.0 571 20 ±5.0 ±200.0 ±50.0 70 ±1,000 1,500
D206RW 5 4.5 - 9.0 533 25 ±12.0 ±83.0 ±21.0 75 ±220 1,500
D207RW 5 4.5 - 9.0 533 25 ±15.0 ±67.0 ±17.0 75 ±220 1,500
D208RW 5 4.5 - 9.0 563 60 ±24.0 ±42.0 ±10.0 71 ±100 1,500
D211RW 12 9.0 - 18.0 205 15 3.3 500.0 125.0 67 3,300 700
D212RW 12 9.0 - 18.0 216 15 5.0 400.0 100.0 77 3,300 700
D213RW 12 9.0 - 18.0 208 15 12.0 167.0 42.0 80 470 700
D214RW 12 9.0 - 18.0 213 15 15.0 133.0 33.0 78 470 700
D215RW 12 9.0 - 18.0 222 15 ±5.0 ±200.0 ±50.0 75 ±1,000 700
D216RW 12 9.0 - 18.0 208 15 ±12.0 ±83.0 ±21.0 80 ±220 700
D217RW 12 9.0 - 18.0 210 15 ±15.0 ±67.0 ±17.0 79 ±220 700
D218RW 12 9.0 - 18.0 219 30 ±24.0 ±42.0 ±10.0 76 ±100 700
D221RW 24 18.0 - 36.0 98 8 3.3 500.0 125.0 70 3,300 350
D222RW 24 18.0 - 36.0 108 8 5.0 400.0 100.0 77 3,300 350
D223RW 24 18.0 - 36.0 104 8 12.0 167.0 42.0 80 470 350
D224RW 24 18.0 - 36.0 104 8 15.0 133.0 33.0 80 470 350
D225RW 24 18.0 - 36.0 106 8 ±5.0 ±200.0 ±50.0 78 ±1,000 350
D226RW 24 18.0 - 36.0 104 8 ±12.0 ±83.0 ±21.0 80 ±220 350
D227RW 24 18.0 - 36.0 104 8 ±15.0 ±67.0 ±17.0 80 ±220 350
D228RW 24 18.0 - 36.0 106 20 ±24.0 ±42.0 ±10.0 78 ±100 350
D231RW 48 36.0 - 72.0 48 6 3.3 500.0 125.0 71 3,300 135
D232RW 48 36.0 - 72.0 56 6 5.0 400.0 100.0 74 3,300 135
D233RW 48 36.0 - 72.0 53 6 12.0 167.0 42.0 78 470 135
D234RW 48 36.0 - 72.0 53 6 15.0 133.0 33.0 78 470 135
D235RW 48 36.0 - 72.0 56 6 ±5.0 ±200.0 ±50.0 74 ±1,000 135
D236RW 48 36.0 - 72.0 53 6 ±12.0 ±83.0 ±21.0 79 ±220 135
D237RW 48 36.0 - 72.0 52 6 ±15.0 ±67.0 ±17.0 80 ±220 135
D238RW 48 36.0 - 72.0 55 12 ±24.0 ±42.0 ±10.0 75 ±100 135
Other input/output combinations are available Mechanical Dimensions
(i.e. 9.0 VDC). Contact the factory for details at:
sales@micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Notes:
1. An external capacitor should be placed from the +Vout pin to the -Vout pin for
single output units and from each output to common for dual output units. For
single output units a 100 µF is recommended, for dual output models ±48 µF
should be used.
2. The Remote On/Off Control input (Pin 3) is referenced to -Vin (Pin 1). Connection
to the pin should be made through a 1k resistor and diode (1N4148). If it is
not used, the control pin should be left open or tied directly to -Vin (Pin 1).
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC, 30 VDC or
48 VDC output. To do this, connect the load across the positive (+Vout) and
negative (-Vout) outputs and float the output common.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Derating Curve
A metal case is available
Contact the factory for details at:
Pin Connections
sales@micropowerdirect.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim Pin Single Dual
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de 1 -Vin -Vin
2 +Vin +Vin
Mechanical Notes:
· All dimensions are typical in inches (mm) 3 Remote ON/OFF
· Tolerance x.xx = ±0.01 (±0.25) 5 NC NC
6 +Vout +Vout
7 -Vout Common
MicroPower Direct
8 NC -Vout
NC = No Connection
www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 · Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 sales@micropowerdirect.com
TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail:
info@compumess.de · www.compumess.de · www.netzteile.de