Hier Klicken für das PDF Dokument!!!

                                                            DLM 600
                                        Near Linear 600W DC Power Supply




NOW AVAILABLE WITH ETHERNET




        Applications
          · Electronic Design/Development
          · Battery Charging
          · Process Control
          · Rackmount ATE Systems
DLM 600                                                                 DLM 600 Key Features
                                                                         · High Power Density
Near Linear Power Supply                                                   600 watts in 1U (1.75 inches) high, half rack (8.5 inches)
                                                                           wide; no top or bottom clearance spacing required.
The DLM 600W Series of programmable power supplies is
                                                                         · Wide Range of Output Voltages
designed to provide continuously variable output voltage and
                                                                           0-5V, 8V, 10V, 20V, 40V, 60V, 80V, 150V and 300V.
current for a broad range of applications in a compact 1U (1.75
inches) high, half-rack (8.5 inch) wide chassis.                         · Low Ripple & Noise
                                                                           Ripple as low as 2.5mV RMS, noise as low as 15mV p-p.
With the use of Zero Voltage Switching (ZVS) technology, these
supplies are able to achieve exceptionally low ripple and noise          · Optional Digital Control
rivaling larger and more expensive linear power supplies. In               · Ethernet LAN / RS232C (16 bit)
                                                                           · IEEE-488.2 / RS232C (12 bit)
addition, the high efficiency and fast load transient response assure
the DLM is ideal for even the most demanding applications.               · Fast Transient Response
                                                                           Recovers in less than 500 µs for a 50-100% or 100-50%
The DLM 600W Models are ideal for high density multiple output             load change.
rackmount requirements or low profile benchtop applications.
Output voltages from 0-5VDC to 0-300VDC and currents from 0-2A           · Preview Pushbutton
to 0-75A are available.                                                    Overvoltage protection, voltage and current preview
                                                                           buttons allow viewing these set points at any time with or
                                                                           without the output enabled.
The cooling air intake is at the front and sides with exhaust at the
rear and sides. Variable speed fans are controlled as a function of      · Efficiency
ambient air temperature and load, thus reducing acoustic noise and         84% typical at maximum output power.
increasing fan life. This allows supplies to be stacked one directly
on top of another without space in between, yielding maximum             · Built-In Down Programming
rackmount packing density and a wide operating temperature of              Standard internal circuitry to speed up response time to
                                                                           down programming changes.
0-50° C. An optional rackmount kit is available to easily mount one
or two units side-by-side.                                               · Autoranging Input Voltage
                                                                           Universal AC input.
The front panel layout makes the DLM 600W Series easy to
use. Voltage and current can be set from individual 10-turn              · Remote Voltage Sense
potentiometer knobs. Control push buttons include power on,                Sense leads are easily connected to a solderless rear
output on, local/remote, voltage/current preview and overvoltage           panel connector.
protection preview. Set-point or actual voltage/ current values can      · Remote Analog Operation
be viewed on two 3.5 digit LED displays.                                   Standard analog programming 0-5V, 0-10V, or 0-5k.
                                                                           Optional isolated analog programming (M51A)
Supplies can be connected in series or parallel. All models
automatically accept any standard single phase input without             · Operating Modes
manual set up.                                                             Constant voltage and constant current with autocrossover
                                                                           and LED indicators.

                                                                         · Simple master/slave paralleling, active current sharing.

                                                                         · CE Mark

                                                                         · 5 Year Warranty
                                                                                                         Ethernet/LAN Option: (M130)
DLM 600                                             GENERAL
                                                    Operating Temperature:
                                                                                                            · 10/100 base-T
                                                                                                            · TCP/IP Protocol
Common Specifications                               0°C to 50°C                                             · ICMP (Ping Server)
                                                    Storage Temperature:                                    · Web Server: Direct control of power supply
VOLTAGE/CURRENT RANGES                              -40°C to 65°C                                             via standard web browser.
Model              Voltage          Current
                                                    Cooling:                                             Disconnect/Polarity Relay Option: (M6)
DLM 5-75           0-5V             0-75A
                                                    Internal variable speed fans with overtemperature    Output disconnect and polarity reversal relays
DLM 8-75           0-8V             0-75A
                                                    protection. Air intake is from the front and sides   controlled via SCPI commands. Single SPST relay in
DLM 10-60          0-10V            0-60A
                                                    with exhaust at rear and sides for maximum           line with each output lead.
DLM 20-30          0-20V            0-30A
DLM 40-15          0-40V            0-15A           rackmount packing density.                           Rated life: 100 Million operations, mechanical;
DLM 60-10          0-60V            0-10A           Remote Sense:                                        100,000 at 70Amps 14Vdc resistive load.
DLM 80-7.5         0-80V            0-7.5A          The maximum allowed load line drop with remote       Software:
DLM 150-4          0-150V           0-4A            sensing is 1V total for DLM 5-75 and DLM 8-75        IVI-COM, LabVIEW® or LabWindow/CVI driver for
DLM 300-2          0-300V           0-2A            model, 2V total for all other models.                Ethernet and IEEE-488.2 can be downloaded at no
                                                    Remote Programming:                                  cost at: www.elgar.com.
OUTPUT
Ripple & Noise:                                     Voltage, current (0-100%) and OVP (5-110%) of full   Regulatory Compliance:
See table on page to the right.                     scale can be programmed by selectable                CE Compliant:
                                                    0-5VDC, 0-10VDC, or 0-5k                               · Low Voltage Directive (73/23/EEC) using
Line Regulation:                                                                                              EN 61010-1, and
Voltage: 0.005% of V max + 2 mV                     Remote Monitoring:
                                                    Voltage or current can be monitored with user-         · EMC Directive (89/336/EEC) using
Current: 0.01% of I max + 2 mA                                                                                EN 61326
See table on page to the right.                     selectable ranges, scaled to 0-5 VDC or 0-10 VDC
                                                    Operational Features:                                Certified to UL 61010-1, CSA C22.2 No. 61010.1 and
Load Regulation:                                                                                         IEC/EN 61010-1
Voltage: 0.005% of V max + 2 mV                     Master/slave parallel operation, up to 4 units of
Current: 0.02% of I max + 5 mA                      the same model can be connected in parallel,         Dimensions:
See table on page to the right.                     with active current sharing control. Series          1U or 1.75" (44 mm) H x 8.5" (216 mm) W x 17" (432
                                                    operation, multiple units of the same model          mm) D, Option M6 depth 20" (508 mm)
Transient Response:                                 can be connected in series, limited by 300Vpk
500 µs to steady-state output voltage (within                                                            Weight:
                                                    between either output terminal and chassis.
0.1% of Vmax) for 50-100% or 100-50% load                                                                9.7 lbs. (4.4 kg)
change                                                                                                   Shipping Weight:
Stability:                                                                                               12.7 lbs. (5.8 kg)
±0.05% of maximum voltage or current over 8
hours after 30 minute warm-up time at fixed line,
load and temperature
Efficiency:
84% typical at maximum output power; 82%                               J1 Connector
typical for DLM 5-75 and DLM 8-75                    1   ANALOG-CONTROL Input                            OPTIONS & ACCESSORIES
                                                     2   EXTERNAL-OFF Return                             ACCESSORIES
Temperature Coefficient:
0.02%/°C of maximum output voltage, 0.03%/°C         3   OVP Programming Input                              Remote Interface Options
of maximum output current                            4   REMOTE-CONTROL Status Output
                                                                                                                       Disconnect & Polarity reversal relays
                                                     5   VOLTAGE-MODE Status Output
                                                                                                                      (10V to 300V models only. This option
INPUT                                                                                                         M6
                                                     6   Auxiliary 5 VDC Return                                       requires at least one of the following op-
                                                     7   Current Monitor Output                                       tions: M9G, M85, M130 or M131)
Voltage and Frequency:
90-132 VAC or 180-264 VAC max, auto ranging,         8   Voltage/Current Monitor Return
                                                                                                             M9G      IEEE-488.2 and RS 232 Interfaces
47-63 Hz, single phase, 2-wire plus ground           9   Voltage Programming Input
                                                                                                                      Locking shafts
Current:                                            10   Current Programming Input                           M13
                                                                                                                      (front panel potentiometers)
11A maximum at 115VAC, 6A maximum at 230            11   Not Used
                                                                                                                      Optically Isolated Analog Programming
VAC                                                 12   V/I/OVP Programming Return                         M51A
                                                                                                                      and Monitoring
Connector:                                          13   Not Used
                                                                                                             M85      Multichannel Slave Interface
IEC 320 with detachable line cord                   14   EXTERNAL-OFF Input (+)
                                                    15   Auxiliary 5 VDC Output (+)                                   Ethernet/LAN and RS232C Interfaces
                                                                                                             M130
                                                                                                                      (16 bit)
                                                    16   OVP Resistance Programming Output
                                                    17   OVP Resistance Programming Return                            Multichannel Slave Interface (16 bit)
                                                                                                             M131
                                                                                                                      (M130 Master ONLY)
                                                    18   FAULT Status Output
                                                    19   Voltage Monitor Output
                                                                                                            Parallel Cable
                                                    20   Voltage Resistance Programming Return
                                                                                                            DLMP1     Paralleling Cable; one cable per slave unit
                                                    21   Voltage Resistance Programming Output
                                                                                                            Rackmount Kit
                                                    22   Current Resistance Programming Output
                                                                                                                      Rackmount Kit for single DLM with filler
                                                    23   Current Resistance Programming Return              DLMRK     panel and for two units mounted side-
                                                    24   LOCAL-LOCKOUT Input                                          by-side
                                                    25   OVP Status Output
                                Output Ratings                              Line Regulation                                Load Regulation
      Model           Voltage        Current       Power           Voltage (0.005%      Current (0.01% of       Voltage (0.005%        Current (0.02% of
                        (VDC)         (ADC)        (Watts)         of Vmax + 2 mV)          Imax + 2 mA)         of Vmax + 2 mV)          Imax + 5 mA)
 DLM 5-75                0-5          0-75          375                2.4mV                   9.5mA                    2.4mV               20mA
 DLM 8-75                0-8          0-75          600                2.4mV                   9.5mA                    2.4mV               20mA
 DLM 10-60              0-10          0-60          600                2.5mV                    8mA                     2.5mV               17mA
 DLM 20-30              0-20          0-30          600                 3mV                     5mA                      3mV                11mA
 DLM 40-15              0-40          0-15          600                 4mV                    3.5mA                     4mV                 8mA
 DLM 60-10              0-60          0-10          600                 5mV                     3mA                      5mV                 7mA
 DLM 80-7.5             0-80          0-7.5         600                 6mV                    2.8mA                     6mV                6.5mA
 DLM 150-4             0-150           0-4          600                9.5mV                   2.2mA                    9.5mV               5.8mA
 DLM 300-2             0-300           0-2          600                17mV                    2.1mA                    17mV                5.4mA



                                             Programming Accuracy 
                                                                                                                                Display Accuracy
                             Ethernet (M130/M131)                GPIB (M9G/M85)
     Model                             Current            OVP                           Current             OVP             Voltage           Current
                      Voltage          (0.25% of
                                                                        Voltage            (0.5% of      (1.0% of 1.1     (0.5% of Vmax     (1.0% of Imax
                                                      (0.5% of 1.1
                    (0.1% of VMax)                                    (0.2% of VMax)
                                         IMax)          x Vmax)                             IMax)          x Vmax)          + 1 count)       + 1 count)
 DLM 5-75                8mV           188mA             44mV             16mV             375mA            55mV             35mV             850mA
 DLM 8-75                8mV           188mA             44mV             16mV             375mA            88mV             50mV             850mA
 DLM 10-60              10mV           150mA             55mV             20mV             300mA           110mV             60mV             700mA
 DLM 20-30              20mV            75mA            110mV             40mV             150mA           220mV            200mV             400mA
 DLM 40-15              40mV            38mA            220mV             80mV              75mA           440mV            300mV             160mA
 DLM 60-10              60mV            25mA            330mV            120mV              50mA           660mV            400mV             110mA
 DLM 80-7.5             80mV            19mA            440mV            160mV              38mA           880mV            500mV              85mA
 DLM 150-4             150mV            10mA            825mV            300mV              20mA            1.65V           850mV              50mA
 DLM 300-2             300mV             5mA             1.65V           600mV              10mA             3.3V             2.5V             30mA
 Readback accuracy is the same as programming accuracy for all parameters except GPIB Voltage readback


                      Ripple and Noise,               OVP                      Stability               Temperature Coefficient
                        Voltage Mode               Adjustment                                                                               Maximum
      Model                                          Range                                                                                Total Remote
                      Ripple         Noise         (5% - 110% of
                                                                       Voltage         Current           Voltage           Current
                                                                                                                                           Sense Drop
                                                                       (0.05% of       (0.05% of         (0.02%/°C         (0.03%/°C
                       (RMS)*         (P-P)*          Vmax)
                                                                         Vmax)           Imax)            of Vmax)          of Imax)
 DLM 5-75               5mV           30mV          0.25-5.5V           2.5mV          37.5mA             1mV/°C          22.5mA/°C             1V
 DLM 8-75               5mV           30mV           0.4-8.8V             4mV          37.5mA            1.6mV/°C         22.5mA/°C             1V
 DLM 10-60              5mV           30mV           0.5-11V              5mV           30mA              2mV/°C           18mA/°C              2V
 DLM 20-30             2.5mV          15mV            1-22V              10mV           15mA              4mV/°C            9mA/°C              2V
 DLM 40-15             2.5mV          15mV            2-44V              20mV           7.5mA             8mV/°C           4.5mA/°C             2V
 DLM 60-10             2.5mV          20mV            3-66V              30mV            5mA             12mV/°C            3mA/°C              2V
 DLM 80-7.5             4mV           20mV            4-88V              40mV          3.75mA            16mV/°C          2.25mA/°C             2V
 DLM 150-4              7mV           40mV          7.5-165V             75mV            2mA             30mV/°C           1.2mA/°C             2V
 DLM 300-2             10mV           60mV           15-330V            150mV            1mA             60mV/°C           0.6mA/°C             2V

 * RMS noise typical from 20 Hz to 20 MHz
 **Specifications in red are improved.
  DC OUTPUT
                                                                              RESET
                                                                                      RS232   RS485   ETHERNET
                                         REM LOC




                                                                     EXT

                                                                              NET
                                                                             ON



                             REM   5     1         5   1
                                                                             OFF                                 AC INPUT
                                                           REM SNS
                                                           SLAVE
                                                                 N/U
                                                                 N/U
                                                                 N/U
                                                                 N/U
                                                                 N/U
                                                                 N/U




                             SNS       PARALLEL I/O




Multi-channel Slave Interface
The multichannel slave interface option, provides the                      Key features include:
user a method to simplify system design when multiple
power supplies are required. Utilizing a single power                       · Single Ethernet, IEEE-488.2 or RS232C address for
supply with either Ethernet, IEEE-488.2 (GPIB) or                             up to 31 power supplies
RS232C, up to 30 additional supplies may be controlled
via a daisy chained RS485 interface. Group commands                         · Lower system costs through reduced cabling
may be sent to all supplies simultaneously to reduce                          and development time
command latency, as well as being able to address each
supply individually. With the RS485 interface, distances                    · Long cable distances between controller and
to the slaves may be extended well beyond the typical                         power supplies
limitations for IEEE-488.2 systems.




                                               Ethernet / LAN,
                                         IEEE-488.2/GPIB or RS232C

                                                                                                      M9G or M130 Master




                                                                                                      M85 or M131 Slave 1




                                                                                                      M85 or M131 Slave 2

                                                                                                      ETC.
DLM 600: Drawings




                                                    **




                                                                                                                           DLMRK
                                                                                                                     (Rackmount kit for one or
                                                                                                                    two supplies side-by-side)




            Top View




           Front View                                                      Rear View
                                                                              * 80V, 150V and 300V models have two position terminal blocks for the output
Dimensions in inches (millimeters)
                                                                              ** M6 Option: 20" (508 mm).



DLM 600: Model Number Description
                    DLM       20 - 30               M9G

  Series

                 Volts

                          Amperes

                         Remote Control Option
                           M6: Disconnect & Polarity reversal relays (10V to 300V models only)
                           M9G: IEEE-488.2 and RS232C Interface
                           M13: Locking shafts (front panel potentiometers)
                           M51A: Optically Isolated Analog Programming and Monitoring
                           M85: Multichannel Slave Interface
                           M130: Ethernet/LAN and RS232C Interfaces
                           M131: Multichannel Slave Interface (M130 Master ONLY)




       P O W E R             E V O L V E D
                                                                                                                                                                Printed in USA
                                                                                                                                                             DLM600 Datasheet
                                                                                                                                                               DLM600DS0205