Hier Klicken für das PDF Dokument!!!

E100I Series
High Isolation
Miniature, 1W SIP
DC/DC Converters
                             Electrical Specifications
                             Speci cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speci cations subject to change without notice.

                               Input
Key Features:                  Parameter                                                         Conditions                         Min.      Typ.      Max.          Units
 1W Output Power                                                                                                5 VDC Input          4.5       5.0       5.5
 3,000 VDC Isolation                                                                                           12 VDC Input         10.8      12.0      13.2
                               Input Voltage Range                                                                                                                    VDC
 Miniature SIP Case                                                                                            24 VDC Input         21.6      24.0      26.4
                                                                                                               48 VDC Input         44.0      48.0      52.0
 >2 MHour MTBF
                               Reverse Polarity Input Current                                                                                            0.3            A
 16 Standard Models
                               Input Filter                                                                           Internal Capacitor
 Industry Standard Pin-Out     Output
                               Parameter                                                         Conditions                         Min.      Typ.      Max.          Units
                               Output Voltage Accuracy                                                                                                  ±3.0           %
                               Line Regulation                                                      For Vin Change of 1%           ±1.2                                %
                               Load Regulation (Note 1)                                                      See Model Selection Guide
                               Ripple & Noise (20 MHz) (Note 2)                                                                                          100       mV P - P
                               Output Power Protection                                                                              120                              %
                               Temperature Coef cient                                                                                 ±0.01             ±0.02       %/ºC
                               Output Short Circuit                                                                Momentary (0.5 Sec.)
                               General
                               Parameter                                                         Conditions                        Min.       Typ.      Max.          Units
                               Isolation Voltage                                                                60 Seconds         3,000                              VDC
                               Isolation Resistance                                                              1,000 VDC         1,000                               M
                               Isolation Capacitance                                                            100 kHz, 1V                    60                       pF
                               Switching Frequency                                                                                   50        90        110           kHz
                               Environmental
                               Parameter                                                         Conditions                         Min.      Typ.      Max.          Units
                               Operating Temperature Range                                                           Ambient        -40       +25       +85            ºC
                               Operating Temperature Range                                                             Case                             +90            ºC
                               Storage Temperature Range                                                                    -55                         +125           ºC
                               Cooling                                                                          Free Air Convection
                               Humidity                                                               RH, Non-condensing                                  95            %
                               Physical
MicroPower Direct              Case Size (5V, 12V & 24V Input Models)                                             0.46 x 0.24 x 0.40 Inches (11.68 x 6.0 x 10.2 mm)
                               Case Size (48V Input Models)                                                       0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
                               Case Material                                                                              Non-Conductive Black Plastic (UL94-V0)
                               Weight                                                                                                                0.06 Oz (1.8g)
                               Reliability Specifications
                               Parameter                                                    Conditions                              Min.      Typ.      Max.         Units
                               MTBF                                                MIL HDBK 217F, 25ºC, Gnd Benign                             4.4                  MHours
                               Absolute Maximum Ratings
                               Parameter                                                         Conditions                         Min.      Typ.      Max.          Units
                                                                                                         5 VDC Input                -0.7                 9.0
                                                                                                       12 VDC Input                 -0.7                18.0
                               Input Voltage Surge (1 Sec)                                                                                                            VDC
                                                                                                       24 VDC Input                 -0.7                30.0
                                                                                                       48 VDC Input                 -0.7                55.0
                               Lead Temperature                                          1.5 mm From Case For 10 Sec                                    260            ºC
                               Internal Power Dissipation                                                  All Models                                   650            mW
                                      Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

      CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
           Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Model Selection Guide
                                 Input                         Output            Load                Fuse Rating
   Model                                                                                  Efficiency
                 Voltage (VDC)         Current (mA)   Voltage Current  Current Regulation             Slow-Blow
  Number                                                                                   (%, Typ)
               Nominal    Range     Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)                  (mA)
   E101I          5      4.5 - 5.5     250       25     5.0    200.0      4.0      8          80          500
   E102I            5        4.5 - 5.5         256           25        9.0   110.0   2.0   8    78       500
   E103I            5        4.5 - 5.5         256           25       12.0   100.0   1.5   10   78       500
   E104I            5        4.5 - 5.5         250           25       15.0    66.0   1.0   8    80       500
    E111I          12       10.8 - 13.2        106           16        5.0   200.0   4.0   8    78       200
   E112I           12       10.8 - 13.2        106           16        9.0   110.0   2.0   8    78       200
   E113I           12       10.8 - 13.2        125           16       12.0   100.0   1.5   8    80       200
   E114I           12       10.8 - 13.2        105           16       15.0    66.0   1.0   8    80       200
   E121I           24       21.6 - 26.4        53             8        5.0   200.0   4.0   8    78       100
   E122I           24       21.6 - 26.4        53             8        9.0   110.0   2.0   8    78       100
   E123I           24       21.6 - 26.4        62             8       12.0   100.0   1.5   8    80       100
   E124I           24       21.6 - 26.4        51             8       15.0    66.0   1.0   8    82       100
   E131I           48       44.0 - 52.0        29             6        5.0   200.0   4.0   8    72       100
   E132I           48       44.0 - 52.0        28             6        9.0   110.0   2.0   8    75       100
   E133I           48       44.0 - 52.0        34             6       12.0   100.0   1.5   8    75       100
   E134I           48       44.0 - 52.0        28             6       15.0    66.0   1.0   8    74       100
Notes:
1. Output load regulation is speci ed for a load change of 20%
                                                                    Derating Curve
   to 100%.
2. When measuring output ripple, it is recommended that
   an external 0.33 F ceramic capacitor be placed from the
   +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However,
   they may not meet all speci cations.
4. The 5V, 12V and 24V input units do not require external
   components to operate, but the use of a low ESR capacitor
   (approximately 10 uF, ESR <1.0 at 100 kHz) mounted
   close to the converter input pins is recommended.
   For 48 VDC input units, an input capacitor should always
   be used. Dependent upon the application, a value between
   4.7 F and 47 uF should be suf cient.
5. It is recommended that a fuse be used on the input of a
   power supply for protection. See the table above for the
   correct rating.


    Capacitive
      Load                   Pin Connections
         (F Max)                 Pin        Description                Mechanical Dimensions
                                  1             -Vin
            220
                                  2            +Vin
                                  3            -Vout
                                  4            +Vout


Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a "dot" or indentation on the side of the unit

Dimensions indicated on the drawing are as follows:

                          Input Voltage
 Dimension
                  5, 12 & 24V            48V
     "W"           0.24 (6.0)          0.29 (7.5)
      "X"         0.05 (1.25)         0.08 (2.00)




                                   CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                           Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de