Hier Klicken für das PDF Dokument!!!
Excelsys Technologies Lt d.
EX40
The EX40 series of power supplies is the configurable open frame power supply series from Excelsys Technologies. Configured to your
particular requirements, the EX40 series ensures that you do not have to make compromises in order to satisfy your system
requirements. Options include, Universal Input, DC inputs and Medically approved units. EX40 has carries full international safety
approvals, UL1950 and EN60950 for the EXS and EXD series, and UL2601-1 and EN6601-1 for the medically approved EXM series..
Boasting a 91.5 x 63 x 30.5mm compact form factor, the EX40 series saves valuable board space.
1. INPUT SPECIFICATIONS
EXS40 EXM40 EXD40
Input Voltage 85-264VAC 85-264VAC 10-18(10) ,18-36(11) ,36-72VDC
Input Frequency Range 47-63Hz 47-63Hz Not Applicable
Inrush Current; 115VAC (cold start) 25A 25A Not Applicable
2. OUTPUT SPECIFICATIONS
Single outputs
Output Voltage 3.3V-48V. See table below
Output Voltage ±5% (All outputs)
Adjust range
Line Regulation ±0.5%
Load Regulation ±3%
Over voltage Protection 125%
Overshoot 10% max.
Response Time 500µSec
Ripple and Noise load 1% Pk-Pk max 20MHz Bandwidth
Single output models (3.3V-48V) Output Current Amps
Output Current 1 3.3V-5V (8) 2 5V-12V (8) 3 12V-15V (8) 4 15V-24V (8)
5 24V-48V (8)
Minimum 0 0 0 0 0
Maximum (4) 6 6-2.5 2.5-2 2-1.3 1.3-0.6
(Convection)
Maximum (5) 8 8-3.3 3.3-2.6 2.6-1.7 1.7-0.8
(Forced Air)
Peak (5,6) 9.5 9.5-4 4-3.3 3.3-2.1 2.1-1
Mulitple outputs
(2 to 3 outputs)
Output Voltage Any output voltage between 3.3V and 48V available as standard. See table below for Output current capabilities
Output Voltage ±5% on V1
Adjust range
Line Regulation ±0.5%
Load Regulation 60%±40% Full Load
V2 and V3 ±5%max
Cross Regulation 60%±40% Full Load
V1: Change V2 and V3) ±0.5%
V2 and V3: Change V1 ±5%max
Over voltage Protection 125%
Overshoot 10% max.
Response Time 500µSec
Ripple and Noise load 1% Pk-Pk max 20MHz Bandwidth
Output Output Minimum Maximum (4) Maximum (5) Peak (5,6)
Voltage (Convection) (Forced Air)
V1 3.3V-48V (8) 0 (7)
4 5 6
V2 2.0V-48V (9) 0 1 1.5 1.5
V3 2.0V-48V (9) 0 0.8 1 1
When calculating power capabilities of each output, please note overall power consumption of PSU and the current limitation
on each output.
Example
V1=5V/4A, V2=12V/1A, V3=15V/0.5A
20CFM system cooling is available.
V1 can deliver up to 5A. V1 Power = 5V x 4A = 20W.
20W power is available for use between other outputs
V2 can deliver up to 1A. V2 Power = 12V x 1A = 12W
8W power is available for use on final output.
V3 can deliver 0.8A. V3 power = 15V x 0.5A = 7.5W
Total power = 39.5W.
Total power is less than 40W rating of PSU.
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Excelsys Technologies Lt d.
3. EMC CHARACTERISTIC
Emissions
Conducted EN55022, FCC part 15 Level B
Radiated EN55022, FCC part 15 Level A
Immunity
Electrostatic Discharge EN61000-4 -2 Level 3
Radiated Immunity EN61000-4 -3 Level 3
Fast Transients (Burst) EN61000-4 -4 Level 3
Input Line Surges EN61000-4 -5 Level 3
Conducted Immunity EN61000-4 -6 Level3
Voltage Dips EN61000-4 -11 Compliant
4. GENERAL SPECIFICATIONS
Hold-up Time 10mS
Efficiency 75%
Switching Frequency 60KHz
Isolation Voltage Input/Output 3000VAC/4000VAC for EXM40
Input Chassis 1500VAC
Approvals and Standards EXS: EN60950, UL1950
EXD: EN60950, Ul1950
EXM: EN6 0601-1, UL2601-1
Leakage Current <100µA
Weight
Size (L x W x H) 91.5mm x 63mm x 30.5mm
MTBF >250,000 Hours MIL HANDBOOK 217F
5. ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range 0°C to 50°C Start up Temperature -20°C. (2)
Derate 2.5%/ °C up to 70°C
Storage Temperature Range -40°C to 85°C
Relative Humidity 5 to 95% Non-Condensing
Vibration 5-500Hz, 0.75G Peak
Notes:
1. All specifications are typical at nominal line, full load and 25°C.
2. Ripple and Noise measurements may not meet published specification for 2mins after -20°C.
3. 10% minimum load required on V1 for full power on V2-V3.
4. Rated with 20CFM. 30W rating convection cooled.
5. 20CFM cooling.
6. 30 seconds maximum duration.
7. 20% Min. load for stated regulation on multiple outputs.
8. Specify 0.1V increments.
9. Specify 0.2V Increments.
10. Derate by 25% for 10-18VDC Input option
11. Derate by 15% for 18-36VDC input option
12. Contact factory for output voltages greater than 48V.
How to Configure your EX40 PSU
EXS 40 123 - 00
Input
Power Output1 Output1 Output1 Option
Code
Specifications of the Power supply detailed above
S=Universal Input Voltage
40 = 40 Watt Output Power
1 = Output 1: 3.3-5V. Nominal 5V
2 = Output 2: 5V-12V. Nominal 12V
3 = Output 3: 12V-15V. Nominal 15V
00 = Option code. If alternative voltage set-points are required, Defined DC input voltages etc, a specific option code will be assigned.
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Excelsys Technologies Lt d.
91.5
83.5
55
63
30.5
Mounting Hole Diameter 4.00mm
Tolerance: ± 0.5mm
Input Connector Molex 09-6 5-2058 Mating 09-5 0-3051
Output Connector Molex 09-6 5-2088 Mating 09-6 5-3081
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim