Hier Klicken für das PDF Dokument!!!

F2000ERW Series
Low Cost, Compact
20W, 2:1 Input Range
DC/DC Converters
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                 Input
Key Features:
                                 Parameter                                                              Conditions               Min.                   Typ.       Max.          Units
· 20W Output Power
                                                                                                                 12 VDC Input      9.0                  12.0       18.0
· 2:1 Input Voltage Range        Input Voltage Range                                                             24 VDC Input 18.0                      24.0       36.0           VDC
· 1,500 VDC Isolation                                                                                            48 VDC Input 36.0                      48.0       75.0
· Efficiency to 86%              Input Filter                                                                             (Pi) Filter
· Compact 1.6 x 2 In. Case       Short Circuit Input Power                                                                                             3,500                      mW
                                 Output
· -40°C to +71°C Operation
                                Parameter                                                               Conditions                           Min.       Typ.       Max.         Units
· Industry Standard Pin-Out
                                Output Voltage Accuracy                                                                                                            ±3.0          %
· Lowest Cost!!                 Line Regulation                                                                 Vin = Min to Max                                   ±0.5          %
                                Load Regulation                                                              Iout = 10% to 100%                                     1.0          %
                                Ripple & Noise (20 MHz)                                                               See Note 1                      1% Vo                    mV P - P
                                Output Power Protection                                                               See Note 3             120                                 %
                                Transient Recovery Time (Note 4)                                                                             200                                µSec
                                                                                                         25% Load Step Change
                                Transient Response Deviation                                                                                ±2.0                                 %
                                Temperature Coefficient                                                                                     ±0.02                               %/°C
                                Output Short Circuit                                                                   Continuous (Autorecovery)
                                 General
                                 Parameter                                                              Conditions                          Min.        Typ.       Max.          Units
                                 Isolation Voltage                                                                       60 Seconds         1,500                                VDC
                                 Isolation Resistance                                                                      500 VDC           500                                  M
                                 Isolation Capacitance                                                                  100 kHz, 1V                     130                       pF
                                 Switching Frequency                                                                                                    300                      kHz
                                 Environmental
                                 Parameter                                                              Conditions                Min.    Typ.                     Max.          Units
                                 Operating Temperature Range                                                                 Ambient
                                                                                                                                  -40     +25                      +71            °C
                                 Storage Temperature Range                                                                        -50                              +125           °C
                                 Cooling                                                                              Free Air Convection
MicroPower Direct                Humidity                                                                   RH, Non-condensing                                      95             %
292 Page Street                  Physical
Suite D                          Case Size                                                                                   2.0 x 1.6 x 0.41 Inches (50.8 x 40.6 x 10.5 mm)
Stoughton, MA 02072
USA                              Case Material                                                                                Metal With Non-Conductive Base (UL94-V0)
                                 Weight                                                                                                                        1.37 Oz (39g)
T: (781) 344-8226                Reliability Specifications
F: (781) 344-8481                Parameter                                                        Conditions                                 Min.       Typ.       Max.         Units
E: sales@micropowerdirect.com
W: www.micropowerdirect.com      MTBF                                                    MIL HDBK 217F, 25°C, Gnd Benign                     1.0                               MHours
                                 Absolute Maximum Ratings
                                 Parameter                                                            Conditions                             Min.       Typ.      Max.           Units
                                                                                                               12 VDC Input                  -0.7                 20.0
                                 Input Voltage Surge (1 Sec)                                                   24 VDC Input                  -0.7                  40.0           VDC
                                                                                                               48 VDC Input                  -0.7                  80.0
                                 Lead Temperature                                                1.5 mm From Case for 10 Sec                                       300            °C
                                 Internal Power Dissipation                                                      All Models                                       5,000           mW
                                      Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

                                                         CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                         Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                         info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
                                   Input                                                    Output                                 Fuse Rating
    Model                                                                                                             Efficiency
                   Voltage (VDC)           Current (mA)                     Voltage        Current        Current                  Slow-Blow
   Number                                                                                                              (%, Typ)
                 Nominal    Range      Full-Load No-Load                     (VDC)        (mA, Max)      (mA, Min)                    (mA)
 F2001ERW          12     9.0 - 18.0     1,937       40                         3.3         5,400           540           86          4,000
 F2002ERW          12     9.0 - 18.0     2,109       40                         5.0         4,000           400           79          4,000
 F2003ERW          12     9.0 - 18.0     2,057       40                        12.0         1,670           167           81          4,000
 F2004ERW          12     9.0 - 18.0     2,032       40                        15.0         1,330           133           82          4,000
 F2005ERW          12     9.0 - 18.0     2,008       40                        24.0           830             83          83          4,000
 F2011ERW          24    18.0 - 36.0      968        20                         3.3         5,400           540           86          2,000
 F2012ERW          24    18.0 - 36.0     1,028       20                         5.0         4,000           400           81          2,000
 F2013ERW          24    18.0 - 36.0     1,004       20                        12.0         1,670           167           83          2,000
 F2014ERW          24    18.0 - 36.0      980        20                        15.0         1,330           133           85          2,000
 F2015ERW          24    18.0 - 36.0      968        20                        24.0           830             83          86          2,000
 F2021ERW          48    36.0 - 75.0      479        10                         3.3         5,400           540           87          1,000
 F2022ERW          48    36.0 - 75.0      502        10                         5.0         4,000           400           83          1,000
 F2023ERW          48    36.0 - 75.0      496        10                        12.0         1,670           167           84          1,000
 F2024ERW          48    36.0 - 75.0      496        10                        15.0         1,330           133           84          1,000
 F2025ERW          48    36.0 - 75.0      484        10                        24.0           830             83          86          1,000
Notes:                                                                                  Derating Curve
1. When measuring output ripple, it is recommended that an external ceramic
   capacitor (approx 1 µF to 10 µF) be placed from the +Vout to the -Vout pins.
2. These units should not be operated with a load under 10% of full load. Operation
   at no-load will not damage the unit, but they may not meet all specifications.
3. Overload protection is provided by a power limiting circuit. Long term operation
   under overload conditions may cause damage to the unit.
4. Transient recovery is measured to within a 1% error band for a load step
   change of 75% to 100%.
5. These converters are specified for operation without external components. How-
   ever, in some applications the addition of input/ouput capacitors will enhance
   stability and reduce output ripple. Recommended capacitor values are:
                     Input                  Output
         Vin
                    Capacitor              Capacitor
      12 VDC          100 µF        1,000 µF per 1A of Iout
      24 VDC          100 µF        1,000 µF per 1A of Iout
      48 VDC          100 µF        1,000 µF per 1A of Iout

   For applications requiring very low output noise levels, a simple LC filter should
   be effective.
6. These units should not be operated over +71°C (see derating curve). Exceeding
   +71°C may damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protec-
   tion. See the Model Selection table above for the correct rating.                                     Mechanical Dimensions
Remote ON/OFF
 Parameter                        Min           Max        Units
 Supply On                         0.5      40.0 or Open   VDC
 Supply Off                       Grnd          <0.5       VDC
 Control Common                          Referenced to Gnd
External Trim (±10%)
                                                                        Pin Connections
                                                                           Pin          Function
                                                                            1           +Vin
                                                                            2           -Vin
                                                                            4       Remote On/Off
                                                                            6          +Vout
                                                                            7          -Vout
                                                                            8           Trim


                  A simple external circuit may be used to
                  adjust the converter output. To adjust
the output DOWN, connect a 5%, 3W resistor between
the plus output pin and the Vout trim pin. To adjust the
output UP, connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin.

For UP/Down trimming capability, connect a 10 kW poten-               Mechanical Notes:
tiometer between the plus and minus outputs with the                  · All dimensions are typical in
wiper arm connected to the Vout trim pin.                               inches (mm)
                                                                      · Tolerance x.xx = ±0.01 (±0.25)


                          MicroPower Direct
                                                  www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                              CompuMess Elektronik
                        292 Page Street Ste D Stoughton, MA 02072                   ·   Telefon (089) 32 15 01 - FAX:Telefax (089) 32·15E-Mail: sales@micropowerdirect.com
                                                                                         TEL: (781) 344-8226 · 0 · (781) 344-8481       01 - 11
                                                                                        info@compumess.de · www.compumess.de · www.netzteile.de