                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                 Input
Key Features:                    Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
· 1W Output Power                                                                                                       5 VDC Input          4.75        5.0       5.25
                                 Input Voltage Range                                                                   12 VDC Input          11.4       12.0       12.6           VDC
· Tightly Regulated
                                                                                                                       24 VDC Input          22.8       24.0       25.2
· Single & Dual Outputs
                                 Input Filter                                                                                Internal Capacitor
· Compact "MiniDip" Case
                                 Reverse Polarity Input Current                                                                                                     0.3             A
· 1,000 VDC Isolation            Output
· >3.5 MHour MTBF                Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
· 24 Standard Models             Output Voltage Accuracy                                                                                                           ±3.0            %
· Industry Standard Pin-Out      Line Regulation                                                              For Vin Min to Max                                  ±0.25            %
· Short Circuit Protected        Load Regulation (Note 1)                                               For Iout = 10% to 100%                                     ±1.0            %
                                 Ripple (20 MHz) (Note 3)                                                                                                10          20        mV P - P
                                 Noise (20 MHz)                                                                                                          50          75        mV P - P
                                 Output Power Protection                                                                                      120                                  %
                                 Temperature Coefficient                                                                                                          ±0.03           %/ºC
                                 Output Short Circuit                                                                             Continuous
                                 General
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                 Isolation Voltage                                                                        60 Seconds        1,000                                 VDC
                                 Isolation Resistance                                                                        500 VDC        1,000                                 M
                                 Isolation Capacitance                                                                   100 kHz, 1V                     60                        pF
                                 Switching Frequency                                                                                                     100                      kHz
                                 Environmental
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                 Operating Temperature Range                                                                 Ambient          -40        +25        +85            ºC
                                 Operating Temperature Range                                                                       Case       -40                   +90            ºC
                                 Storage Temperature Range                                                                                    -55                  +125            ºC
                                 Cooling                                                                                    Free Air Convection
                                 Humidity                                                                    RH, Non-condensing                                      95            %

MicroPower Direct Physical
292 Page Street                  Case Size (Single Output)                                                                0.787 x 0.39 x 0.26 Inches (20.0 x 10.0 x 6.5 mm)
Suite D                          Case Material                                                                                       Non-Conductive Black Plastic (UL94-V0)
Stoughton, MA 02072
                                 Weight                                                                                                                                   0.07 Oz (2.1g)
USA
                                 Reliability Specifications
T: (781) 344-8226                Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
F: (781) 344-8481                MTBF                                                     MIL HDBK 217F, 25ºC, Gnd Benign                     3.5                              MHours
E: sales@micropowerdirect.com
W: www.micropowerdirect.com      Absolute Maximum Ratings
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                                                                                                        5 VDC Input           -0.7                  9.0
                                 Input Voltage Surge (1 Sec)                                                           12 VDC Input           -0.7                 18.0           VDC
                                                                                                                       24 VDC Input           -0.7                 30.0
                                 Lead Temperature                                                1.5 mm From Case For 10 Sec                                        300            ºC
                                 Internal Power Dissipation                                                               All Models                                450           mW
                                      Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.


                                                               CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                               Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                               info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
                                Input                                     Output                              Fuse Rating
  Model                                                                                          Efficiency
                Voltage (VDC)           Current (mA)            Voltage Current   Current                     Slow-Blow
 Number                                                                                           (%, Typ)
             Nominal     Range      Full-Load No-Load            (VDC) (mA, Max) (mA, Min)                       (mA)
G101ER         5      4.75 - 5.25      294        30               5.0   150.0      15.0            68            500
G102ER         5      4.75 - 5.25      286        30               9.0   111.0      12.0            70            500
G103ER         5      4.75 - 5.25      282        30              12.0    83.0       9.0            71            500
G104ER         5      4.75 - 5.25      273        30              15.0    67.0       7.0            73            500
G111ER         12     11.4 - 12.6      122        15               5.0   150.0      15.0            68            200
G112ER         12     11.4 - 12.6      116        15               9.0   111.0      12.0            72            200
G113ER         12     11.4 - 12.6      119        15              12.0    83.0       9.0            70            200
G114ER         12     11.4 - 12.6      113        15              15.0    67.0       7.0            74            200
G121ER         24     22.8 - 25.2       61         8               5.0   150.0      15.0            68            100
G122ER         24     22.8 - 25.2       61         8               9.0   111.0      12.0            68            100
G123ER         24     22.8 - 25.2       57         8              12.0    83.0       9.0            73            100
G124ER         24     22.8 - 25.2       55         8              15.0    67.0       7.0            75            100
Notes:
1. Output load regulation is specified for a load          Derating Curve
   change of 10% to 100%.
2. These units should not be operated with a load
   under 10% of full load. Operation at no-load may
   cause damage to the unit.
3. These converters will operate without external
   components. However, when measuring output
   ripple, it is recommended that an external ceramic
   capacitor be placed from the +Vout pin to the -Vout
   pin. An input capacitor will enhace stability over
   temperature and input line variations. Recom-
   mended capacitor values are given in the table
   below. For applications requiring very low output
   noise levels, a simple LC filter should be effective.

              Input             Output Capacitor
    Vin                   Vout
            Capacitor            Single   Dual
   5 VDC      4.7 µF      5 VDC 10.0 µF 4.7 µF
  12 VDC      2.2 µF      9 VDC  4.7 µF  2.2 µF
  24 VDC      1.0 µF     12 VDC 2.2 µF   1.0 µF
                         15 VDC 1.0 µF 0.47 µF             Mechanical Dimensions (Single Output)
4. It is recommended that a fuse be used on the input
   of a power supply for protection. See the Model
   Selection table above for the correct rating.




                                    Pin
                                 Connections
                                 Pin     Function
                               1       -Vin
                               7        NC
                               9      +Vout
                              11      -Vout
                              14       +Vin
                            NC = No Connection




            Notes:
            · All dimensions are typical in inches (mm)
            · Tolerance x.xx = ±0.01 (±0.25)
            · Pin 1 is marked by a "dot" or indentation
               on the top of the unit