Hier Klicken für das PDF Dokument!!!

G200E Series
Low Cost, 2W
Compact MiniDIP
DC/DC Converters
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.

Key Features:                    Input
· 2W Output Power                Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
· Miniature SIP Case                                                                                                    5 VDC Input           4.5        5.0        5.5
· UL Approved (File E245422)     Input Voltage Range                                                                  12 VDC Input           10.8       12.0       13.2           VDC
· Single & Dual Outputs                                                                                               24 VDC Input           21.6       24.0       26.4
· 1,000 VDC Isolation            Input Filter                                                                                Internal Capacitor
· >3.5 MHour MTBF                Reverse Polarity Input Current                                                                                                     0.3             A
· 24 Standard Models             Output
· LOWEST COST!!                 Parameter                                                               Conditions                           Min.       Typ.       Max.          Units
                                Output Voltage Accuracy                                                                                                 ±2.5                       %
                                Output Voltage Balance                                          Dual Output , Balanced Loads                            ±1.0                       %
                                Line Regulation                                                           For Vin Change of 1%                          ±1.2                       %
                                Load Regulation                                                                        See Model Selection Guide
                                Ripple & Noise (20 MHz)                                                                                                 100         150        mV P - P
                                Output Power Protection                                                                                      120                                   %
                                Temperature Coefficient                                                                                                ±0.02      ±0.03          %/ºC
                                 Output Short Circuit                                                                      Momentary (1.0 Sec.)
  RoHS Compliant                 General
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
                                 Isolation Voltage                                                                       60 Seconds         1,000                                 VDC
                                 Isolation Resistance                                                                        500 VDC        1,000                                 M
                                 Isolation Capacitance                                                                  100 kHz, 1V                      60                        pF
                                 Switching Frequency                                                                                                     75                       kHz
                                 Environmental
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
                                 Operating Temperature Range                                                                 Ambient          -40       +25        +85             ºC
                                 Storage Temperature Range                                                                                    -55                  +125            ºC
                                 Cooling                                                                                    Free Air Convection
                                 Humidity                                                                   RH, Non-condensing                                      95             %
                                 Physical
MicroPower Direct                Case Size (5V 12V & 24V Input Models)                                                       0.8 x 0.40 x 0.32 Inches (20.4 x 10.2 x 8.2 mm)
292 Page Street                  Case Material                                                                                      Non-Conductive Black Plastic (UL94-V0)
Suite D                          Weight                                                                                                                                   0.07 Oz (2.1g)
Stoughton, MA 02072
                                 Reliability Specifications
USA
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
T: (781) 344-8226                MTBF                                                    MIL HDBK 217F, 25ºC, Gnd Benign                      3.5                              MHours
F: (781) 344-8481                Safety Standards                                                                    UL 1950, EN 60950, IEC 60950
E: sales@micropowerdirect.com
                                 Safety Approvals                                                                       UL, cUL; File No. E245422
W: www.micropowerdirect.com
                                 Absolute Maximum Ratings
                                 Parameter                                                               Conditions                          Min.       Typ.       Max.          Units
                                                                                                                        5 VDC Input          -0.7                   9.0
                                 Input Voltage Surge (1 Sec)                                                          12 VDC Input           -0.7                  18.0           VDC
                                                                                                                      24 VDC Input           -0.7                  30.0
                                 Lead Temperature                                               1.5 mm From Case For 10 Sec                                         300            ºC
                                 Internal Power Dissipation                                                               All Models                                450           mW
                                      Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

                                                           CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                           CompuMess 32 15 01 - 0GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                           Telefon (089) Elektronik · Telefax (089) 32 15 01 - 11
                                                           Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                           info@compumess.de · www.compumess.de · www.netzteile.de
                                                           info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
                               Input                          Output             Load                                          Fuse Rating
Model                                                                                                             Efficiency
               Voltage (VDC)           Current (mA)  Voltage Current  Current  Regulation                                      Slow-Blow
Number                                                                                                             (%, Typ)
             Nominal    Range      Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)                                           (mA)
G201E           5      4.5 - 5.5      494        30     5.0   400.0     40.0      15                                  81          1,000
G202E           5      4.5 - 5.5      488        30     9.0   222.0     23.0      15                                  82          1,000
G203E           5      4.5 - 5.5      476        30    12.0   167.0     17.0      15                                  84          1,000
G204E           5      4.5 - 5.5      476        30    15.0   133.0     14.0      15                                  84          1,000
G205E           5      4.5 - 5.5      488        30    ±5.0  ±200.0    ±20.0      15                                  82          1,000
G206E           5      4.5 - 5.5      482        30    ±9.0  ±111.0    ±12.0      15                                  83          1,000
G207E           5      4.5 - 5.5      470        30   ±12.0   ±83.0     ±9.0      15                                  85          1,000
G208E           5      4.5 - 5.5      470        30   ±15.0   ±67.0     ±7.0      15                                  85          1,000
G211E          12    10.8 - 13.2      203        15     5.0   400.0     40.0      15                                  82           500
G212E          12    10.8 - 13.2      201        15     9.0   222.0     23.0      15                                  83           500
G213E          12    10.8 - 13.2      196        15    12.0   167.0     17.0      15                                  85           500
G214E          12    10.8 - 13.2      196        15    15.0   133.0     14.0      15                                  85           500
G215E          12    10.8 - 13.2      201        15    ±5.0  ±200.0    ±20.0      15                                  83           500
G216E          12    10.8 - 13.2      198        15    ±9.0  ±111.0    ±12.0      15                                  84           500
G217E          12    10.8 - 13.2      194        15   ±12.0   ±83.0     ±9.0      15                                  86           500
G218E          12    10.8 - 13.2      194        15   ±15.0   ±67.0     ±7.0      15                                  86           500
G221E          24    21.6 - 26.4      100         8     5.0   400.0     40.0      15                                  83           250
G222E          24    21.6 - 26.4       99         8     9.0   222.0     23.0      15                                  84           250
G223E          24    21.6 - 26.4       97         8    12.0   167.0     17.0      15                                  86           250
G224E          24    21.6 - 26.4       97         8    15.0   133.0     14.0      15                                  86           250
G225E          24    21.6 - 26.4       99         8    ±5.0  ±200.0    ±20.0      15                                  84           250
G226E          24    21.6 - 26.4       98         8    ±9.0  ±111.0    ±12.0      15                                  85           250
G227E          24    21.6 - 26.4       96         8   ±12.0   ±83.0     ±9.0      15                                  87           250
G228E          24    21.6 - 26.4       96         8   ±15.0   ±67.0     ±7.0      15                                  87           250
Notes:
1. Output load regulation is specified for a load change of 10% to
                                                                       Derating Curve
   100%.
2. These units should not be operated with a load under 10% of
   full load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
   However, when measuring output ripple, it is recommended
   that an external ceramic capacitor be placed from the +Vout
   pin to the -Vout pin for single output units and from each out-
   put to common for dual output units. An input capacitor will
   enhance stability over temperature and input line variations.
   Recommended capacitor values are given in the table below.
   For applications requiring very low output noise levels, a simple
   LC filter should be effective.
                     Input              Output Capacitor
            Vin                  Vout
                   Capacitor             Single     Dual
           5 VDC     4.7 µF     5 VDC 10.0 µF 4.7 µF
          12 VDC     2.2 µF     9 VDC    4.7 µF    2.2 µF
          24 VDC     1.0 µF    12 VDC 2.2 µF       1.0 µF                            Mechanical Dimensions
                               15 VDC 1.0 µF 0.47 µF
4. Dual output units may be connected to provide a 10V, 18V, 24V
   or 30 VDC output. To do this, connect the load across the posi-
   tive (+Vout) and negative (-Vout) outputs and float the output
   common
5. It is recommended that a fuse be used on the input of a power
   supply for protection. See the Model Selection table above for
   the correct rating.

          Pin Connections
           Pin    Single      Dual         Pin     Single     Dual
             1     -Vin       -Vin          9      +Vout     +Vout
             7      NC         NC           11     No Pin    -Vout
             8    -Vout     Common          14      +Vin      +Vin

    Notes:
    · All dimensions are typical in inches (mm)
    · Tolerance x.xx = ±0.01 (±0.25)
    · Pin 1 is marked by a "dot" or indentation on the top of the unit




                        MicroPower Direct
                                                 www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                             CompuMess Elektronik
                       292 Page Street Ste D Stoughton, MA 02072           · Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 sales@micropowerdirect.com
                                                                               TEL: (781) 344-8226 · FAX: (781) 344-8481 · E-Mail:
                                                                            info@compumess.de · www.compumess.de · www.netzteile.de