G200MHI Series
Compact MiniDIP, 2W
4 kVAC Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
Parameter Conditions Min. Typ. Max. Units
· 2W Output Power 5 VDC Input 4.5 5.0 5.5
· 4,000 VAC Isolation Input Voltage Range 12 VDC Input 10.8 12.0 13.2 VDC
· Low Leakage Current 24 VDC Input 21.6 24.0 26.4
Input Filter Internal Capacitor
· Compact MiniDIP Case
Reverse Polarity Input Current 0.3 A
· Single & Dual Outputs Leakage Current 2.0 µA
· 2.0 MH MTBF Output
Parameter Conditions Typ. Min. Max. Units
· Industry Standard Pin-Out
Output Voltage Accuracy ±2.0 ±4.0 %
· EN 60950 Approved Output Voltage Balance Dual Outputs, Balanced Loads ±0.1 ±1.0 %
Line Regulation Vin = Min to Max ±1.2 ±1.5 %
Load Regulation, See Note 1 See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2 100 150 mV P - P
Ripple & Noise (20 MHz) Over Line, Load & Temp. 200 mV P - P
Ripple & Noise (20 MHz) 15 mV rms
Temperature Coefficient ±0.01 ±0.02 %/°C
Output Short Circuit Momentary (0.5 Sec.)
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage, Rated 60 Seconds 4,000 VAC
Isolation Test Voltage Flash Tested For 1 Sec 6,000 VDC
Isolation Resistance 500 VDC 10 G
Isolation Capacitance 100 kHz, 1V 15 20 pF
Switching Frequency 50 80 100 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -25 +25 +60 °C
Operating Temperature Range Case +90 °C
Storage Temperature Range -40 +125 °C
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
Physical
Case Size 0.94 x 0.54 x 0.34 Inches (23.8 x 13.7 x 8.62 mm)
Case Material Non-Conductive Black Plastic (UL94-V0)
Weight 0.18 Oz (5.1g)
MicroPower Direct Reliability Specifications
292 Page Street Parameter Conditions Min. Typ. Max. Units
Suite D MTBF MIL HDBK 217F, 25°C, Gnd Benign 2.0 MHours
Stoughton, MA 02072 Safety Standards EN 60950, IEC 60950, EN 60601, IEC 60601
USA
Safety Approvals EN 60950, IEC 60950
T: (781) 344-8226 Absolute Maximum Ratings
F: (781) 344-8481 Parameter Conditions Min. Typ. Max. Units
E: sales@micropowerdirect.com 5 VDC Input -0.7 9.0
W: www.micropowerdirect.com Input Voltage Surge (1 Sec) 12 VDC Input -0.7 18.0 VDC
24 VDC Input -0.7 30.0
Lead Temperature 1.5 mm From Case For 10 Sec 260 °C
Internal Power Dissipation All Models 650 mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
www.micropowerdirect.com
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide www.micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de
Input Output Capacitive Load
Model Efficiency Fuse Rating
Number Voltage (VDC) Current (mA) Voltage Current Current Load Regulation Slow-Blow
(%, Typ)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (µF, Max) (%, Max) (mA)
G201MHI 5 4.5 - 5.5 606 60 5.0 400.0 8.0 330 12 66 1,000
G202MHI 5 4.5 - 5.5 600 60 12.0 165.0 3.0 330 10 66 1,000
G203MHI 5 4.5 - 5.5 605 60 15.0 133.0 2.5 330 10 66 1,000
G204MHI 5 4.5 - 5.5 553 60 ±12.0 ±83.0 ±1.5 ±100 10 72 1,000
G205MHI 5 4.5 - 5.5 542 60 ±15.0 ±66.0 ±1.0 ±100 10 73 1,000
G211MHI 12 10.8 - 13.2 253 30 5.0 400.0 8.0 330 12 66 500
G212MHI 12 10.8 - 13.2 250 30 12.0 165.0 3.0 330 10 66 500
G213MHI 12 10.8 - 13.2 252 30 15.0 133.0 2.5 330 10 66 500
G214MHI 12 10.8 - 13.2 224 30 ±12.0 ±83.0 ±1.5 ±100 10 74 500
G215MHI 12 10.8 - 13.2 220 30 ±15.0 ±66.0 ±1.0 ±100 10 75 500
G221MHI 24 21.6 - 26.4 126 15 5.0 400.0 8.0 330 12 66 200
G222MHI 24 21.6 - 26.4 125 15 12.0 165.0 3.0 330 10 66 200
G223MHI 24 21.6 - 26.4 126 15 15.0 133.0 2.5 330 10 66 200
G224MHI 24 21.6 - 26.4 112 15 ±12.0 ±83.0 ±1.5 ±100 10 74 200
G225MHI 24 21.6 - 26.4 110 15 ±15.0 ±66.0 ±1.0 ±100 10 75 200
Notes:
1. Load regulation is measured for a load change of 20% to 100%.
Derating Curve
2. When measuring output ripple, it is recommended that an external 0.47 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. For noise
sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple.
3. Operation at no-load will not damage these units. However, they may not meet
all specifications.
4. For dual output units, the maximum capacitive load is given for each output.
5. Dual output units may be connected to provide a 24 VDC or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout)
outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input
source with a highly inductive impedance may affect the stability of the con-
verter. In applications where the converter output loading is high and input
power is supplied over long lines, it may be necessary to use a capacitor on
the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor
be mounted close to the converter. For 5V input units a 2.2 µF is recommended,
for 12V input units, a 1.0 µF; and for 24V units a 0.47 µF.
7. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin Single Dual
1 -Vin -Vin
7 NC NC
8 NC Common
9 +Vout +Vout
10 -Vout -Vout
16 +Vin +Vin
NC = No Connection
Mechanical Notes:
· All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 ·CompuMess Elektronik GmbH(781) 344-8481 · E-Mail: sales@micropowerdirect.com
TEL: (781) 344-8226 · FAX: · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de