Hier Klicken für das PDF Dokument!!!

    GECA20
    20 Watt Series

    Commercial Wide-Range Input                                                       2 Year Warranty

· Wide-Range AC Input 90-264 VAC
· Low Height Footprint - 3.5"x 2"x 0.85"
· Conducted EMI Exceeds FCC Class B and
  CISPR 22 Class B
· Single Output Models in Four Popular Voltages
· Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03,
  IEC and EN60950-1
· CB Report Available
· RoHS Compliant
·       Marked to LVD




    Specifications                                                                       Unless otherwise noted, all parameters are nominal values measured at 120 VAC @25°C and 0-95%
                                                                                         relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory.

    ACInput                                                                              OutputNoise
    90-264 VAC, 47-63 Hz single phase.                                                   0.5% RMS, 1% Pk-Pk, 20 MHz bandwidth, differential mode. Measured with
                                                                                         scope probe directly across output terminals of the power supply with load
    InputCurrent
                                                                                         terminated with 0.1F capacitor.
    Maximum input current at 120 VAC, 60 Hz with full load: 0.5 A.
                                                                                         TransientResponse
    Hold-UpTime
                                                                                         Main Output - 500 s typical response time for return to within 0.5% of final
    10 ms minimum from loss of AC input at 20 W load, nominal line (120 VAC).
                                                                                         value for a 50% load step within the regulation limits of minimum and
    OutputPower                                                                          maximum load, i/t< 0.2 A/s. Maximum voltage deviation is 3.5%.
    Normal continuous output power is 20 W, 25 W peak for 60 s.                          Start-up overshoot less than 5% under nominal conditions; less than 2%
    OverloadProtection                                                                   under all conditions at shutdown.
    Fully protected against short circuit and output overload. Short circuit             SwitchingFrequency
    protection is cycling type power limit. Factory set to begin power limiting          70 kHz +/-10 kHz.
    at approximately 27 W.
                                                                                         VoltageAdjustment
    OvervoltageProtection                                                                See table for individual model features. Adjustable voltage outputs
    Built in with firing point set per grid at top of next page. OVP firing shuts        are preset at factory. Outputs are capable of a minimum of +/- 5% change
    down the converter.                                                                  from nominal setting.
    Efficiency                                                                           EMI/EMCCompliance
    72 to 80% depending upon model.                                                      All models include built-in EMI filtering to meet the following emissions
    Turn-onTime                                                                          requirements:
    Less than 1 s at 120 VAC, 25°C (inversely proportionate to input voltage and         EMISPECIFICATIONS                                     COMPLIANCELEVEL
    thermistor temperature).
                                                                                         Conducted Emissions                                   EN55022 Class B; FCC Class B
    InputProtection                                                                      Static Discharge                                      EN61000-4-2, Level 3
    Internal AC fuse provided on all units. Designed to blow only if a catastrophic      RF Field Susceptibility                               EN61000-4-3, Level 3
    failure occurs in the unit. Fuse does not blow on overload or short circuit.         Fast Transients/Bursts                                EN61000-4-4, Level 3
    InrushCurrent                                                                        Surge Susceptibility                                  EN61000-4-5, Level 3
    Inrush is limited by internal thermistor. The inrush at 240 VAC, averaged            SafetyApprovals
    over the first AC half-cycle under cold start conditions will not exceed 37A.        SL Power Electronics, Corp. declares under our sole responsibility
    TemperatureCoefficient                                                               that all GECA models are in conformity with the applicable requirements of
    0.03%/°C typical on all outputs.                                                     EN60950 following the provisions of the Low Voltage Directive 73/23/EEC.

    TemperatureRange                                                                     All GECA models are approved to UL60950-1: 2003,
    Designed for 0 to 45°C operation at full rated output power; derate output           CSA-22.2 No. 60950-1-03, IEC and EN60950-1
    current and total output power by 2.5% per °C above 45°C.                            MTBF
                                                                                         120kHrs.

                 CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                        Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
   GECA20
   20 Watt Series

   Commercial Wide-Range Input

 Commercial                        Output                    Current                      Line                         Load                         OVP                  Ripple& 
   Model                            (V)                                                Regulation                    Regulation                   SetPoint              Noise(P-P)
   GECA20-5G                        5.1 V                      4.0 A                     +/-0.5%                         +/-3%                      7.0±1.0 V                 1%
   GECA20-12G                        12 V                     1.67 A                     +/-0.5%                         +/-3%                     16.8±2.4 V                 1%
   GECA20-15G                        15 V                     1.34 A                     +/-0.5%                         +/-3%                     21.0±3.0 V                 1%
   GECA20-24G                        24 V                     0.84 A                     +/-0.5%                         +/-3%                     33.6±4.8 V                 1%


   EnvironmentalSpecifications                                                                     GECA20SeriesMechanicalSpecifications
   ENVIRONMENT                 OPERATING                      NON-OPERATING                        CON1:
                                                                                                   MOLEX P/N 26-60-4030, w/center PIN Removed
   Temperature (A)             0 to 45°C                      -40 to +85°C
                                                                                                   0.156 [3.96 mm] CTR Header
   Humidity (A)                20 to 90% RH                   10 to 95% RH
   Shock (B)                   20 gpk                         40 gpk                               CON2:
   Altitude                    -500 to 10,000 ft              -500 to 40,000 ft                    MOLEX P/N 26-60-4040, 0.156 [3.96 mm] CTR Header
   Vibration (C)               1.5 grms' 0.0032 g2/Hz         5 grms' 0.026 g2/Hz
                                                                                                   Input J1
   A. Units should be allowed to warm up/operate under non-condensing                              PIN 1)                        AC Line
      conditions before application of power.                                                      PIN 3)                        AC Neutral
   B. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction,
                                                                                                   OutputJ2
      3 orthogonal axes, total 6 shocks.
                                                                                                                                 SingleOutput
   C. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to
      2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and                             PIN 1)                        + Output
      1 hr./axis non-operating.                                                                    PIN 2)                        + Output
                                                                                                   PIN 3)                        Common
                                                                                                   PIN 4)                        Common
                                                                                                   MatingConnector               HousingP/N                     ContactsP/N
                                                                                                   MOLEX
                                                                                                   Input                09-50-3031              08-52-0072
                                                                                                   Output               09-50-3041              08-52-0072
                                                                                                   Note: 5A maximum recommended current per Connector PIN
                                                                                                   Weight
                                                                                                   0.5 lbs Max [0.23 kg Max.]
                                                                                                   Tolerance
                                                                                                   X.XX=0.030
                                                                                                   X.XXX=0.010 [0.mm]




                 CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                        Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de


Data Sheet © 2006 SL Power Electronics, Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.8/21/06