     GLC40 Commercial
     40 Watt Global Performance Switchers

                                                                        FEATURES:
                                                                        · Cost-effective power source
                                                                        · Universal input 90-264 Vac
                                                                        · 2-year warranty
                                                                        · Single and multiple outputs
                                                                        · Overload and overvoltage protection
                                                                        · Built-in EMI filter
                                                                        · UL1950, CSA-C22.2 No. 234 Level 3,
                                                                          IEC950 and EN60950
                                                                        · Operation at no-load
                                                                        ·      marked to LVD


     SPECIFICATIONS:
     Ac Input                                                          Voltage Adjust
     90-264 Vac, 47-63 Hz single phase.                                Factory set on standard unit; however, optional
                                                                       potentiometer adjusts voltage from 4.7 V to OVP point
     Input Current                                                     (6.2 V nominal) on the +5 V output.
     Maximum input current at 120 Vac, 60 Hz with full rated
     output load not to exceed 1.3 A.                                  Efficiency
                                                                       70% typical depending on model.
     Output Power
     Normal continuous output power is 40 W for unrestricted           Turn-on Time
     natural convection cooling, 45 W peak for 60 seconds.             Less than 1 second at 120 Vac, 25°C (inversely
     During peak load conditions output regulation may                 proportional to input voltage and thermistor temperature).
     exceed total regulation and noise limits.
                                                                       Input Protection
     Output Regulation                                                 Internal ac fuse provided on all units. Designed to blow
     Regulation for multiple-output models measured by                 only if a catastrophic failure occurs in the unit. Fuse does
     ±40% load change from 60% rated load with all other               not blow on overload or short circuit.
     outputs at 60% full rated load and a line voltage change
     from low line to high line. Initial set tolerance is measured     Inrush Current
     with all outputs at 60% of full rated load. Output voltage        Inrush limited by internal thermistors. Inrush at 240 Vac,
     V1 requires 20% load for proper regulation of multiple-           averaged over the first ac half-cycle under cold start
     output models. Regulation for single-output models                conditions will not exceed 37 A.
     measured by changing from 5% to 50% load or 50% load
     to full load in either direction.                                 Temperature Coefficient
                                                                       0.03%/°C typical on all outputs.
     Power Limit
     Factory set to begin power limiting at approximately 55 W.        EMI/EMC Compliance
     Fully protected against short circuit and output overload.        All models include built-in EMI filtering to meet the
     Short circuit protection is cycling type power limit.             following emissions requirements:
                                                                       EMI SPECIFICATIONS            COMPLIANCE LEVEL
     Output Noise                                                      Conducted Emissions           EN55022 Class A; FCC Class A
     0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential                Static Discharge              EN61000-4-2, 6 kV contact, 8 kV air
     mode. Measured with noise probe directly across output            RF Field Susceptibility       EN61000-4-3, 3 V/meter
     terminals of the power supply.                                    Fast Transients/Bursts        EN61000-4-4, 2 kV, 5 kHz
                                                                       Surge Susceptibility          EN61000-4-5, 1 kV diff., 2 kV com.
     Transient Response
     Main Output: 500 µs typical response time for return to           Safety
     within 0.5% of final value for a 50% load step change, i/         All GLC models are approved to UL1950, CSA-C22.2 No.
     t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/           234 Level 3, IEC950 and EN60950.
     shutdown overshoot less than 3%.

     Overvoltage Protection
     Built in on V1 with firing point set per table. OVP firing
     reduces output #1 and #2 to less than 50% of nominal
     voltage in 50 ms.
                              CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                 Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de



24
GLC40 Commercial 40 Watt Multiple Output

Commercial                                            Output             Output                                                                        Total
Model             Output No.            Output       Minimum            Maximum             V1 OVP Set                   Noise P-P                   Regulation

GLC40A                1                  +5.1 V         1A                3A                 +6.2 ± 0.6 V                   50 mV                         2%

                      2                  +12 V          0A                2A                                                120 mV                        6%

                      3                  -12 V          0A               0.4 A                                              120 mV                        5%

GLC40B                1                  +5.1 V         1A                3A                 +6.2 ± 0.6 V                   50 mV                         2%

                      2                  +15 V          0A               1.5 A                                              150 mV                        6%

                      3                  -15 V          0A               0.4 A                                              150 mV                        5%

GLC40D                1                  +5 V           1A                3A                 +6.2 ± 0.6 V                   50 mV                         2%

                      2                  +24 V          0A                1A                                                240 mV                        6%

                      3                  -12 V          0A               0.4 A                                              120 mV                        5%

GLC40-3.3             1                  3.3 V          0A                8A                 +4.2 ± 0.6 V                   33 mV                         2%

GLC40-5               1                   5V            0A                8A                 +6.2 ± 0.6 V                   50 mV                         2%

GLC40-12              1                  12 V           0A               3.3 A               +14 ± 1.1 V                    120 mV                        2%

GLC40-15              1                  15 V           0A               2.7 A              +18.5 ± 1.5 V                   150 mV                        2%

GLC40-24              1                  24 V           0A               1.7 A              +28.5 ± 2.5 V                   240 mV                        2%

GLC40-28              1                  28 V           0A               1.4 A               +34 ± 2.8 V                    280 mV                        2%

GLC40-48              1                  48 V           0A               0.83 A              +55 ± 4.0 V                    480 mV                        2%



GLC40 MECHANICAL SPECIFICATIONS




Environmental
                             Operating             Non-operating
Specification
                                    o
Temperature (A)              0 to 50 C              -40 to +85oC            A. Units should be allowed to warm up/operate under non-condensing conditions
                                                                               before application of power. Derate output current and total output power by 2.5%
Humidity (A)               0 to 95% RH              0 to 95% RH
                                                                               per °C above 50°C.
Shock (B)                      20 gpk                   40 gpk              B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
                                                                               orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
Altitude                  -500 to 10,000 ft       -500 to 40,000 ft         C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
Vibration (C)         1.5 grms, 0.003 g2/Hz       5 grms, 0.026 g2/Hz          total 6 shocks.