     GLC50 Commercial/GLM50 Medical
     50 Watt Output Global Performance Switchers

                                                                        FEATURES:
                                                                        · Cost-effective power source
                                                                        · Universal input 90-264 Vac
                                                                        · 2-year warranty
                                                                        · Compact (4.25" x 2.50" x 1.25"; meets 1U applications)
                                                                        · Overload and overvoltage protection
                                                                        · Conducted EMI exceeds FCC Class B and CISPR 22
                                                                          Class B (Commercial models) and CISPR 11 Class B
                                                                          (Medical models)
                                                                        · Commercial UL1950, CSA22.2 No. 950 and
                                                                          IEC 950, EN60950 approvals
                                                                        · Medical UL2601, CSA22.2 No. 601, IEC601-1,
                                                                          EN60601-1
     SPECIFICATIONS:                                                    ·     marked to LVD
     Ac Input
     90-264 Vac, 47-63 Hz single phase.                                 Temperature Coefficient
                                                                        0.03%/°C typical on all outputs.
     Input Current
     Maximum input current at 120 Vac, 60 Hz with full rated            Output Noise
     output load: 1.5 A                                                 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
                                                                        mode. Measured with noise probe directly across output
     Hold-Up Time                                                       terminals of the power supply.
     15 ms minimum from loss of ac input at full load, nominal
     line (115 Vac).                                                    Transient Response
                                                                        500 µs typical response time for return to within 0.5% of
     Output Power                                                       final value for a 50% load step change. i/t<0.2 A/µs.
     50 W continuous, 60 W peak. Peak ratings are for 60 s              Maximum voltage deviation is 3.5%. Startup/shutdown
     maximum duration, 10% duty cycle. During peak load                 overshoot less than 3%.
     condition, output regulation may exceed total regulation
     limits.                                                            Voltage Adjustment
                                                                        Built-in potentiometer adjusts V1 ±5%.
     Output Regulation
     To maintain specified regulation on multi-output models,           EMI/EMC Compliance
     output #1 load power must be at least 1/5th of, and not            All models include built-in EMI filtering to meet the
     greater than 5 times output #2 load power.                         following emissions requirements:
                                                                        EMI SPECIFICATIONS            COMPLIANCE LEVEL
     Overload Protection                                                Conducted Emissions GLC       EN55022 Class B; FCC Class B
     Fully protected against short circuit and output overload.         Conducted Emissions GLM       EN55011 Class B; FCC Class B
     Short circuit protection is cycling type power limit on            Static Discharge              EN61000-4-2, 6 kV contact, 8 kV air
     outputs 1 & 2; foldback type on output 3. Recovery after           RF Field Susceptibility       EN61000-4-3, 3 V/meter
     fault is automatic. See output ratings chart for additional        Fast Transients/Bursts        EN61000-4-4, 2 kV, 5 kHz
     notes or conditions.                                               Surge Susceptibility          EN61000-4-5, 1 kV diff., 2 kV com.

     Efficiency                                                         Commercial Leakage Current
     70-85% at full rated load, nominal input voltage, depend-          160 µA 254 Vac @ 60 Hz input (with no deviations).
     ing on model and load distribution.
                                                                        Commercial Safety
     Minimum Load                                                       All GLC models are approved to UL1950, CSA22.2 No.
     Operating without minimum load will not degrade                    234 Level 3, IEC950 and EN60950.
     reliability, but regulation may be affected. Multiple output
     models require 20% minimum load on V1 for proper                   Medical Leakage Current
     regulation. Single models require 5% minimum load.                 100 µA 264 Vac @ 60 Hz input (normal conditions).

     Input Protection                                                   Medical Safety
     Internal ac fuse provided. Designed to blow only if a              All GLM models are approved to UL2601, CSA22.2 No.
     catastrophic failure occurs in the unit--fuse does not blow        601, IEC601-1 and EN60601-1.
     on overload or short circuit.

     Inrush Current
     Inrush is limited by internal thermistors. Inrush at 240 Vac,
     averaged over the first ac half-cycle under cold start
     conditions will not exceed 37 A.
                            CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de


30
GLC50 Commercial/GLM50 Medical 50 Watt Multiple Output

 Commercial            Medical                                                                                                                                                        Total
                                                                                                              Minimum Load
 Model                 Model                   Output No.               Output               Current                                   OVP Setpoint             Noise P-P          Regulation (A)
                                                                                                                   (B)
 GLC50A                GLM50A                        1                 +5.05 V                  4A                0.8 A                 6.2 ± 0.6 V                50 mV               2%
                                                     2                  +12 V                  2.5 A                                                              120 mV            +10%, -5%
                                                     3                  -12 V                  0.2 A                                                              120 mV               3%
 GLC50B                GLM50B                        1                 + 5.1 V                  4A                   0.8 A              6.2 ± 0.6 V                50 mV               2%
                                                     2                  +15 V                  2.5 A                                                              150 mV            +10%, -5%
                                                     3                  -15 V                  0.2 A                                                              150 mV               3%
 GLC50D                GLM50D                        1                 +5.1 V                   4A                   0.8 A              6.2 ± 0.6 V                50 mV               2%
                                                     2                  +24 V                  1.5 A                                                              240 mV            +10%, -5%
                                                     3                  -12 V                  0.2 A                                                              120 mV               3%
 GLC50G                GLM50G                        1                 +3.3 V                   4A                   0.8 A              4.2 ± 0.6 V                33 mV               2%
                                                     2                  +12 V                  2.5 A                                                              120 mV            +10%, -5%
                                                     3                  -12 V                  0.2 A                                                              120 mV               3%
 GLC50-3.3             GLM50-3.3                     1                  3.3 V                   8A                     0                4.2 ± 0.6 V                66 mV               2%
 GLC50-5               GLM50-5                       1                   5.1 V                  8A                     0                6.2 ± 0.6 V               75 mV                  2%
 GLC50-12              GLM50-12                      1                   12 V                  4.2 A                   0                 14 ± 1.1 V               120 mV                 2%
 GLC50-15              GLM50-15                      1                   15 V                  3.3 A                   0                18.5 ± 1.5 V              150 mV                 2%
 GLC50-24              GLM50-24                      1                   24 V                  2.1 A                   0                 28 ± 2.5 V               240 mV                 2%
 GLC50-28              GLM50-28                      1                   28 V                  1.8 A                   0                34.5 ± 2.8 V              280 mV                 2%
 GLC50-48              GLM50-48                      1                   48 V                  1.1 A                   0                 54 ± 3.0 V               480 mV                 2%

A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.



GLC50/GLM50 MECHANICAL SPECIFICATIONS




 Environmental
                                     Operating                        Non-operating
 Specification
                                               o
 Temperature (A)                      0 to 50 C                         -40 to +85oC
 Humidity (A)                      0 to 95% RH                          0 to 95% RH                       A. Units should be allowed to warm up/operate under non-condensing conditions
                                                                                                             before application of power. derate output current and total output power by 2.5%
 Shock (B)                              20 gpk                              40 gpk                           per °C above 50°C.
                                                                                                          B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
 Altitude                        -500 to 10,000 ft                   -500 to 40,000 ft                       orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                                                                                          C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
 Vibration (C)                 1.5 grms, 0.003 g2/Hz                5 grms, 0.026 g2/Hz                      total 6 shocks.