     GLC65 Commercial/GLM65 Medical
     65 Watt Single Output Global Performance Switchers

                                                                       FEATURES:
                                                                       · 4.1 W/in3
                                                                       · Compact (3.0" x 5.0" x 1.06")
                                                                       · Ultra-high efficiency (up to 94%) using patented
                                                                         technology
                                                                       · Meets harmonic requirements of IEC1000-3-2, Class A
                                                                       · Conducted EMI exceeds FCC Class B and CISPR 22
                                                                         Class B (Commercial models) and CISPR 11 Class B
                                                                         (Medical models)
                                                                       · 2-year warranty
                                                                       · Exempt from line harmonics standard EN61000-3-2
                                                                       · Commercial Approved to UL1950, IEC950, EN60950,
                                                                         CSA22.2 No. 950
                                                                       · Medical Approved to UL2601, EN60601, CSA22.2
     SPECIFICATIONS:
                                                                         No. 601.1
     Ac Input                                                          · Multiple output versions also available
     90-264 Vac, 47-63 Hz single phase.                                ·      marked to LVD

     Input Current
     Maximum input current at minimum output voltage and
     output overload will be less than 1.7 A. Meets input
     current harmonic requirements of IEC1000-3-2.
                                                                       Inrush Current
     Output Power                                                      Inrush is limited by internal thermistor. The inrush at 240
     Normal continuous output power is 65 W, 75 W peak for             Vac, averaged over the first ac half-cycle under cold start
     60 s. The 3.3 Vdc unit is 36.3 W and the 5 Vdc unit is 55 W       conditions will not exceed 37A.
     continuous.
                                                                       EMI/EMC Compliance
     Hold-Up Time                                                      All models include built-in EMI filtering to meet the
     20 ms from loss of ac input at 65 W load, from 120 Vac            following emissions requirements:
     input.                                                            EMI SPECIFICATIONS            COMPLIANCE LEVEL
                                                                       Conducted Emissions GLC65     EN55022 Class B; FCC Class B
     Overload Protection                                               Conducted Emissions GLM65     EN55011 Class B: FCC Class B
     Fully protected against short circuit and output overload.        Static Discharge              EN61000-4-2, 6 kV contact, 8 kV air
     Short circuit protection is cycling type power limit.             RF Field Susceptibility       EN61000-4-3, 3 V/meter
                                                                       Fast Transients/Bursts        EN61000-4-4, 2 kV, 5 kHz
     Output Noise                                                      Surge Susceptibility          EN61000-4-5, 1 kV diff., 2 kV com.
     0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
     mode. Measured with scope probe directly across output            Commercial Leakage Current
     terminals of the power supply with load terminated with           Under normal conditions, leakage current is 425 µA with
     0.1 µF capacitor.                                                 132 Vac @ 60 Hz input.

     Transient Response                                                Commercial Safety
     Main output: 500 µs typical response time for return to           All GLC models are approved to UL1950, CSA22.2 No.
     within 0.5% of final value for a 50% load step within the         950, IEC950 and EN60950.
     regulation limits of minimum and maximum load,
     i/t<0.2 A/µs. Maximum voltage deviation is 3.5%.                  Medical Leakage Current
     Startup/shutdown overshoot less than 3%.                          The maximum leakage current under single-fault condi-
                                                                       tions (254 Vac @ 50 Hz) is 120 µA. Under normal
     Voltage Adjustment                                                conditions, leakage current is 31µA with 132 Vac @ 60 Hz
     Adjustable potentiometer capable of ±5% change from               input.
     nominal setting.
                                                                       Medical Safety
     Efficiency                                                        All GLM models are approved to UL2601, CSA22.2 No.
     82 to 94% minimum at full rated load, nominal input               601, IEC601-1 and EN60601. Consult factory for approval
     voltage, depending on model.                                      status.

                           CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                               Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de




36
GLC65 Commercial/GLM65 Medical 65 Watt Single Output

Commecial         Medical
                                          Output          Current         Total Regulation         V1 Adjustment            V1 OVP Setpoint             Ripple and Noise
Model             Model
GLC65-5           GLM65-5                   5.1 V           11 A                2%                       ± 5%                   6.2 ± 0.6 V                    1%
GLC65-12          GLM65-12                  12 V           5.5 A                2%                       ± 5%                   14 ± 1.1 V                     1%
GLC65-15          GLM65-15                  15 V           4.3 A                2%                       ± 5%                  18.5 ± 1.5 V                    1%
GLC65-18          GLM65-18                  18 V           3.6 A                2%                       ± 5%                   21.7 ± 2.0                     1%
GLC65-24          GLM65-24                  24 V           2.7 A                2%                       ± 5%                   28 ± 2.5 V                     1%
GLC65-28          GLM65-28                  28 V           2.3 A                2%                       ± 5%                   34 ± 2.8 V                     1%
GLC65-48          GLM65-48                  48 V           1.35 A               2%                       ± 5%                   55 ± 4.0 V                     1%




GLC65/GLM65 MECHANICAL SPECIFICATIONS




                       CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                             Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de


Environmental
                             Operating               Non-operating
Specification
Temperature (A)              0 tp 50oC                -40 to +85oC
                                                                                  A. Units should be allowed to warm up/operate under non-condensing conditions
Humidity (A)                0 to 95% RH               0 to 95% RH
                                                                                  before application of power. Derate output current and total output power by 2.5%
Shock (B)                     20 gpk                      40 gpk                  per °C above 50°C.
                                                                                  B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Altitude                -500 to 10,000 ft           -500 to 40,000 ft                 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
Vibration (C)          1.5 grms, 0.003 g2/Hz        5 grms, 0.026 g2/Hz           C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
                                                                                  total 6 shocks.