     GLC75 Commercial/GLM75 Medical
     75 Watt Single Output Global Performance Switchers
                                                                      FEATURES:
                                                                      · Cost-effective single-output power source
                                                                      · 3.4" x 5.75" x 1.56" (meets 1U applications)
                                                                      · Universal input 90-264 Vac
                                                                      · 2-year warranty
                                                                      · Complies with EN61000-3-2 Class A
                                                                      · Also available in multiple output versions
                                                                      · Conducted EMI exceeds FCC Class B and CISPR 22
                                                                        Class B (Commercial models) and CISPR 11 Class B
                                                                        (Medical models)
                                                                      · Commercial Approved to UL1950, CSA22.2 No. 234
                                                                        and IEC950, EN60950
                                                                      · Medical Approved to UL2601-1, IEC601-1 and
                                                                        CSA22.2 No. 601
     SPECIFICATIONS:                                                  ·     marked to LVD
     Ac Input
     90-264 Vac, 47-63 Hz single phase.
                                                                      Inrush Current
     Input Current                                                    Inrush limited by internal thermistors. Inrush at 240 Vac,
     Maximum input current at 120 Vac, 60 Hz with full rated          averaged over the first ac half-cycle under cold start
     output load not to exceed 2.3 A.                                 conditions will not exceed 37 A.

     Output Power                                                     Temperature Coefficient
     Normal continuous output power is 75 W for unrestricted          0.03%/°C typical on all outputs.
     natural convection cooling; 110 W with 26 cfm airflow.
                                                                      Power Fail
     Output Regulation                                                A standard TTL or CMOS compatible output goes low
     Regulation measured by changing from 5% to 50% load              (< 0.5 V) 5ms before output voltage drops more than 4%
     or 50% load to full load in either direction.                    below nominal voltage upon loss of ac power. Signal is
                                                                      factory set to trip on 84 to 94 Vac brown-out depending
     Overload Protection                                              upon incoming line impedance and distortion. Other
     Factory set to begin power limiting at approximately 120         settings are available through adjustment of built-in
     W (GLC 75-5 is set at approximately 100 W). Fully                potentiometer (consult factory for assistance). Output will
     protected against short circuit and output overload. Short       stay low for 20 ms minimum.
     circuit protection is cycling type power limit.
                                                                      EMI/EMC Compliance
     Output Noise                                                     All models include built-in EMI filtering to meet the
     0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential               following emissions requirements:
     mode. Measured with noise probe directly across output           EMI SPECIFICATIONS            COMPLIANCE LEVEL
     terminals of the power supply.                                   Conducted Emissions GLC75     EN55022 Class B; FCC Class B
                                                                      Conducted Emissions GLM75     EN55011 Class B; FCC Class B
     Transient Response                                               Static Discharge              EN61000-4-2, 6 kV contact, 8 kV air
     Main Output: 500 µs typical response time for return to          RF Field Susceptibility       EN61000-4-3, 3 V/meter
     within 0.5% of final value for a 50% load step change, i/        Fast Transients/Bursts        EN61000-4-4, 2 kV, 5 kHz
     t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/          Surge Susceptibility          EN61000-4-5, 1 kV diff., 2 kV com.
     shutdown overshoot less than 3%.                                 Line Frequency Harmonics      EN61000-3-2 Class A

     Overvoltage Protection                                           Commercial Safety
     Standard on all models.                                          All GLC models are approved to UL1950, CSA22.2 No.
                                                                      234 Level 3, IEC950 and EN60950. Consult factory for
     Voltage Adjust                                                   approval status.
     Factory set on standard unit; however, potentiometer
     adjusts voltage ±5% minimum. Consult factory for                 Medical Leakage Current
     application assistance.                                          70 µA 264 V @ 50 Hz (normal conditions).

     Efficiency                                                       Medical Safety
     72-85% depending on model.                                       All GLM models are approved to UL2601-1, CSA-C22.2
                                                                      No. 601.1, IEC601-1 and EN60601-1. Consult factory for
     Input Protection                                                 approval status.
     Internal ac fuse provided. Designed to blow only if a
     catastrophic failure occurs in the unit--fuse does not blow
     on overload or short circuit.
                                     CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                        Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de



40
GLC75 Commercial/GLM75 Medical 75 Watt Single Output

Commercial       Medical                            Output      Output Maximum   Output Maximum          Output                                                    Total
                                   Output
Model            Model                             Minimum             (A)              (B)               Peak           V1 OVP Set           Noise P-P          Regulation
GLC75-5          GLM75-5            5.1 V            0A              13.7 A          19.6 A               21 A           6.2 ± 0.6 V            50 mV                1%

GLC75-12         GLM75-12           12 V             0A              6.3 A           9.1 A               9.5 A           15.6 ± 1.1 V          120 mV                1%

GLC75-15         GLM75-15           15 V             0A                  5A          7.3 A               7.7 A           18.5 ± 1.5 V          150 mV                1%

GLC75-24         GLM75-24           24 V             0A              3.1 A           4.6 A                5A              28 ± 2.5 V           240 mV                1%

GLC75-28         GLM75-28           28 V             0A              2.7 A            4A                 4.4 A            34 ± 2.8 V           280 mV                1%
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W.
B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W.




GLC75/GLM75 MECHANICAL SPECIFICATIONS




                                            CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                                Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

 Environmental
                               Operating                   Non-operating
 Specification
                                       o
 Temperature (A)                0 to 50 C                    -40 to +85oC
 Humidity (A)                 0 to 95% RH                    0 to 95% RH
                                                                                    A. Units should be allowed to warm up/operate under non-condensing conditions
 Shock (B)                        20 gpk                        40 gpk                 before application of power.
                                                                                    B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
 Altitude                   -500 to 10,000 ft             -500 to 40,000 ft            orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                                                                    C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
 Vibration (C)             1.5 grms, 0.003 g2/Hz          5 grms, 0.026 g2/Hz          total 6 shocks.