Hier Klicken für das PDF Dokument!!!

     GPC50 Commercial
     50 Watt Global Performance Switchers

                                                                        FEATURES:
                                                                        · Wide-range ac input 85-264 Vac
                                                                        · 2-year warranty
                                                                        · Approved to UL1950, IEC950 and CSA22.2-234 L3
                                                                        · Exceeds FCC and CISPR22 Class B conducted
                                                                          emissions requirements
                                                                        · Single and multiple outputs
                                                                        ·     marked to LVD




     SPECIFICATIONS:
     Ac Input                                                           Environmental
     85-264 Vac, 47-63 Hz single phase.                                 Designed for 0 to 50°C operation at full rated output
                                                                        power; derate output current and total output power by
     Input Current                                                      2.5% per °C above 50°C. See Environmental and
     Maximum input current at 120 Vac, 60 Hz with full rated            Packaging Specifications on next page.
     output load: 1.5 A
                                                                        Output Noise
     Hold-Up Time                                                       0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
     20 ms minimum from loss of ac input at full load, nominal          mode. Measured with noise probe directly across output
     line (115 Vac).                                                    terminals of the power supply.

     Output Power                                                       Transient Response
     50 W continuous, 60 W peak. Peak ratings are for 60 s              Main output--500 µs typical response time for return to
     maximum duration, 10% duty cycle. During peak load                 within 0.5% of final value for a 50% load step change. i/
     condition, output regulation may exceed total regulation           t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
     limits.                                                            shutdown overshoot less than 3%.

     Overload Protection                                                Voltage Adjustment
     Fully protected against short circuit and output overload.         Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
     Short circuit protection is cycling type power limit on
     outputs 1 & 2; foldback type on output 3. Recovery after           Commercial EMI/EMC Compliance
     fault is automatic. See output ratings chart for additional        All models include built-in EMI filtering to meet the
     notes or conditions.                                               following emissions requirements:
                                                                        EMI SPECIFICATIONS           COMPLIANCE LEVEL
     Overvoltage Protection                                             Conducted Emissions          EN55022 Class B; FCC Class B
     Crowbar provided on V1.                                            Static Discharge             EN61000-4-2, 6 kV contact, 8 kV air
                                                                        RF Field Susceptibility      EN61000-4-3, 3 V/meter
     Efficiency                                                         Fast Transients/Bursts       EN61000-4-4, 2 kV, 5 kHz
     65% at full rated load, nominal input voltage, depending           Surge Susceptibility         EN61000-4-5, 1 kV diff., 2 kV com.
     on model and load distribution.
                                                                        Leakage Current
     Turn-on Time                                                       0.7 mA 254 Vac @ 60 Hz input.
     Less than 1 second at 120 Vac, 25°C (inversely propor-
     tional to input voltage and thermistor temperature).               Safety
                                                                        Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
     Input Protection                                                   and EN60950; UL file #E135803 commercial; CSA
     Internal ac fuse provided. Designed to blow only if a              #LR46516 all models. The output(s) are intended for
     catastrophic failure occurs in the unit.                           safety earthed Signal Output and Intermediate Circuits
                                                                        only. All DC outputs are SELV under normal and single
     Inrush Current                                                     fault conditions.
     Inrush is limited by internal thermistors. Inrush at 240 Vac
     under cold start conditions will not exceed 34 A.

     Temperature Coefficient
     0.03%/°C typical on all outputs.



                           CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                               Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

32
GPC50 Commercial 50 Watt Multiple Output

Commercial                                                                                       Output                                                             Total
                           Output No.               Output           Output Minimum                                  Output Peak           Noise P-P                                      Notes
Model                                                                                           Maximum                                                         Regulation (A)

GPC50A                           1                  +5 V                    0.4 A                   5A                     7A                50 mV                     2%
                                 2                  +12 V                    0A                     2A                     3A                120 mV                    5%                 B.C,D
                                 3                  -12 V                    0A                    0.5 A                   1A                120 mV                    3%                   D
GPC50F                           1                  +5 V                    0.4 A                   5A                     7A                50 mV                     2%
                                 2                  +12 V                    0A                    1.2 A                  1.5 A              120 mV                    3%                    D
                                 3                  -12 V                    0A                    0.5 A                   1A                120 mV                    3%                    D
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B.To maintain these regulation conditions, the 5.1 V current must be at least 1/4 of V2 and not greater than 5 times the V2 current.
C. Requires +5 V to be adjusted within ±1% with at least a 0.4 A load to maintain regulation on this output since its centering voltage tracks the V1 adjustment.
D. Requires +5 V to have at least a 0.4 A load.




GPC50 MECHANICAL SPECIFICATIONS




 Environmental
                                      Operating                       Non-operating
 Specification
  Temperature (A)              See individual specs                     -40 to +85oC
 Humidity (A)                        0 to 95% RH                        0 to 95% RH
                                                                                                           A. Units should be allowed to warm up/operate under non-condensing conditions
 Shock (B)                               20 gpk                              40 gpk                           before application of power.
                                                                                                           B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
  Altitude                        -500 to 10,000 ft                   -500 to 40,000 ft                       orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                                                                                           C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
  Vibration (C)                1.5 grms, 0.003 g2/Hz                5 grms, 0.026 g2/Hz                       total 6 shocks.



                             CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                     Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de