            GPFM600 Medical
            600 Watt Global Performance Switchers

                                                               FEATURES:
                                                              · Small package (12.00" x 5.50" x 3.09")
                                                              · Power factor corrected to EN61000-3-2 Class A
                                                              · Operating range to 60°C ambient
                                                              · 85 to 264 Vac Input
                                                              · Medically Approved to UL2601-1, IEC601-1, CSA
                                                                C22.2 No. 601.1.2
                                                              · 2 year warranty
                                                              ·     marked to LVD




SPECIFICATIONS:
Ac Input                                                       Inrush Current
85-264 Vac, 47-63 Hz single phase.                             Limit inrush current to 125% of maximum operating
                                                               current. Turn on time of the power supply not to exceed 3
Output Power                                                   seconds over the full input voltage and frequency range.
Continuous output power, 600 watts.
                                                               EMI/EMC Compliance
Hold-upTime                                                    All models include built-in EMI filtering to meet emissions
20 ms minimum from loss of ac input until output reaches       requirements:
3% below nominal.                                              EMI SPECIFICATIONS         COMPLIANCE LEVEL
                                                               Conducted Emissions        EN55011 Class B; FCC Class B
Line and Load Regulation                                       Static Discharge           EN61000-4-2, 6 kV contact, 8 kV air
±1% over the entire input voltage and frequency range,         RF Field Susceptibility    EN61000-4-3, 3 V/meter
and over the entire output current range.                      Fast Transients/Bursts     EN61000-4-4, 2 kV, 5 kHz
                                                               Surge Susceptibility       EN61000-4-5, 1 kV diff., 2 kV com.
Minimum Load
No minimum load required.                                      Vibration and Shock
                                                               Model meets MIL-STD 810E, method 514.4 Category.
Overload Protection
Current limit 105% minimum, 125% maximum of the                Environmental
specified full load current.                                   Designed for 0 to 60°C operation, derate output current
                                                               and total output power by 2.5% per °C above 50°C.
Output Noise
100 mV pk-pk maximum @ 20 MHz bandwidth,                       Medical Leakage Current
50 mV pk-pk maximum ripple.                                    150 µA under normal conditions. Maximum under single
                                                               fault conditions, 250 µA. Patient sink leakage with 120
Transient Response                                             Vac, 60 Hz applied to any output with respect to the
Maximum of 5% change in Vout for a load change of 12.5 A.      chassis will be less than 500 µA.
Recovers to ±1% within 500u sec.
                                                               Medical Safety Agency
Overvoltage Protection                                         Approved to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1.
Built in, OVP crowbar reduces output voltage below
nominal rating in less than 50 ms. Output voltage decay
is dependent upon loading.

DC Power Good
Optocoupler isolated output indicates that the DC output
is equal to or greater than 21.6 (-0 + 0.25) volts. This
signal shall be driven when in the active `DC Good' state.

Efficiency
Minimum of 75% under full load and input of 120 Vac 60 Hz.
                    CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                       Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
GPFM600 Medical
600 Watt Global Performance Switchers
                                                     Output
Commercial Model                Output                                 OVP Setpoint                    Total Regulation                    Noise P-P
                                                  Maximum(A)
GPFM600-24                      24 Vdc                25 A              28.2 ± 1.2 V                           1%                            100 mV




GPFM600 MECHANICAL SPECIFICATIONS

INPUT: J1
MOLEX P/N 43160-31-3

PIN 1: AC LINE
PIN 2: AC NEUTRAL
PIN 3: EARTH GROUND

OUTPUT: J2
MOLEX P.N. 39-29-1147
14 PIN RIGHT ANGLE HEADER

PIN 1: +24 V
PIN 2: +24 V
PIN 3: +24 V RETURN
PIN 4: +24 V RETURN
PIN 5: N/A
PIN 6: AC GOOD
PIN 7: AC GOOD RETURN
PIN 8: +24 V
PIN 9: +24 V
PIN 10: +24 V RETURN
PIN 11: +24 V RETURN
PIN 12: N/A
PIN 13: DC GOOD
PIN 14: DC GOOD RETURN




               CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                  Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

                                                                                                                      Dimensions:             Inches
Environmental
                          Operating            Non-operating                                                                                 Millimeters
Specification
Temperature (A)            0 to 60oC            -18 to +60oC
Humidity (A)             0 to 97% RH            0 to 97% RH         A. Units should be allowed to warm up/operate under non-condensing conditions
                                                                       before application of power. Cooling provided by internal fan-- heatsink
Shock (B)                    20 gpk                 40 g pk            temperatures should not exceed 90ºC for extended periods in the installation.
                                                                    B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Altitude               -500 to 10,000 ft      -500 to 40,000 ft        orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                                                    C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
Vibration (C)         1.5 grms, 0.003 g2/Hz   5 grms, 0.026 g2/Hz      total 6 shocks.




                                                                                                                                                             113